Quick Details

Model Number: RTK-3300
Brand Name: RTK
Place of Origin: China (Mainland)
High vacuum system: degree up to 10-6Pa
Analysis station: 1-3

Specifications

Description

Specific surface area and porosity are the important physical parameter of porous materials, They are typically measured by physical
adsorption method. 
Under the condition of a certain cold shower, the analyzer would choose the appropriate gas adsorption,
and let the gas molecules adsorbed on the entire surface of the sample that would be tested, the indirect research of specific
surface and porosity properties of pore materials would be taken by sensors.


The basic principle of instrument is based on temperature physical adsorption instrument of static volumetric method. So the
instrument can have many data analysis such as single point, multi-point BET specific surface area, Langmuir, the BJH pore surface
area, pore distribution, total entrance and the square measure of the data analysis. 
Measure range of specific surface area is from
0.01 M2/g to unlimited, the range of aperture analysis is from 0.35nm to 500nm.


Characteristics

-Vacuum volumetric method of specific surface area and porosity analyzer, Comply with the national standard: GB/T 19587-2004;
-
Apply to specific surface and porosity measure on pore or micropore, measurement process is complete automatic;
-Intelligent gas system, automatically select refined /Rough gas intake mode, consider analysis precision and efficiency as well;
-
Preset pressure controlled accurately by servo valve and magnetic valve;
-
A variety of Optional analysis of gas and baths in cold environment;

Specifications

 
Control Mode    Automatic controlled by software
Communication mode     RS485, upgraded to the USB or network interface
Built-in Detector    Three pressure sensors, including a pressure sensor of pirani vacuum silicon
Analysis station    1~3
Volume of sampling    0.1-3mL
Reaction Gas    N2, Ar,CO2
Gas Purity >99.995 %
Calibration Gas      He
Control of Gas Flow      PID
Sample Cell       Erect type, quartz material, half- round bottom
Degassing Station    1-3 degassing stations of built-in, 6 degassing stations of external sample cell.
All in One Valve Unit    Integrated valve bank, pile-up valve, gas circuit, pressure sensor
Vacuum System       Two-stage rotary vacuum pump, turbo molecular pump if necessary
Vacuum Purity     1*10-2 pa, 1*10-6 pa can be reached if on the condition of molecular pump
Dewar     2L-4L high capacity, staying warm is no more than 100 hours
Jacking System      Automatically controlled by lift
Software     Dedicated analysis workstation of software, based on Windows platform software
Data Export    Support TXT text output, which makes the exchange data with drawing tools like Origin more convenient