| Brand Name: | Konan |
|---|---|
| Temperature of Media: | High Temperature |
| Material: | Alloy |
| Pressure: | High Pressure |
| Standard or Nonstandard: | Standard |
| Model Number: | 414S302C-Y |
| Place of Origin: | Japan |
Quick Details
Specifications
Return Kind of barrier to combine MTL728+
414S302C- 414S303C- 414S603C- 414S604C- 416S302C-
416S303C- 416S603C- 416S604C-
EⅡBT5 SAF3-5
414S302M- 414S303M- 414S603M-i 414S604M- 416S302M-
416S303M- 416S603M- 416S604M-
in the case of other explosion-proof barriers and combination *1
Structure of the main valve Pilot spool type Pilot ceramic slide type
Port size Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2
Effective area of valve 25mm2 30mm2 51mm2 60mm2 24mm2 28mm2 51mm2 60mm2
Working pressure 0.20.7MPa 0.120.7MPa
Ambient temp. -550℃ -1060℃
Explosion-proof standard Intrinsic safety construction
Operating condition
1. Use with specified safety barrier.
for i2G4 explosion-proof valves, use them with MTL728+ safety barrier.
for Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the
conditions described below (note *1).
2. Parts and connections cannot be changed.
3. Use 1 explosion-proof barrier for each solenoid valve.
11.Konan Intrinsic Safety 454 series 5-port solenoid valves spool valve
Intrinsic safety valves can be used for applications that require similar explosion class/ignition degree to d2G4 or Exd II BT5 type (explosion-proof enclosure construction). without need for expensive connection tools and complex installation work that are inevitable for explosion-proof enclosure types, the intrinsic safety valves achieve highly reliable explosion-proof performance.
Return Hold Kind of barrier to combine MTL728+
454S202C- 454S203C- 454S403C- 454S404C- 454D202C-
454D203C- 454D403C- 454D404C-
EⅡBT5 SAF3-5
454S202M- 454S203M- 454S403M- 454S404M- 454D202M-
454D203M- 454D403M- 454D404M-
in the case of other explosion-proof barriers and combination *1
Structure of the main valve Pilot spool type
Port size
Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2
Effective area of valve 22mm2 40mm 22mm 40mm2
Working pressure 0.20.7MPa
Ambient temp. -550℃
Explosion-proof standard Intrinsic safety construction
Operating condition
- Use with specified safety barrier
- for i2G4 explosion-proof valves, use them with MTL728+ safety barrier.
- for Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the
- conditions described below (note *1).
- 2. Parts and connections cannot be changed.
- 3. Use 1 explosion-proof barrier for each solenoid valve
Konan Intrinsic Safety Solenoid Valves 414/416 series 5-port solenoid valves Terminal block ZA Spool valve/Ceramic slide valve
Return
Kind of barrier to combine
EⅡBT5
SAF3-5
414S302M-A 414S303M-A 414S603M-A 414S604M-A416S302M-A
416S303M-A 416S603M-A 416S604M-A
in the case of other explosion-proof barriers and combination *1
Structure of the main valve Pilot spool type
Pilot ceramic slide type Port size
Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2
Effective area of valve
25mm2 30mm2 51mm2 60mm2 24mm2 28mm2 51mm2 60mm2
Working pressure 0.20.7MPa 0.120.7MPa
Ambient temp. -550℃ -1060℃
Explosion-proof standard Intrinsic safety construction
Operating condition
1. Use with specified safety barrier.
for Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the
conditions described below (note *1).
2. Parts and connections cannot be changed.
3. Use 1 explosion-proof barrier for each solenoid valve.
Note1
in the case of other barriers and combination
Konan 454, 414, 416 series intrinsic safety solenoid valves have passed equipment qualification tests for intrinsic safety solenoid valve.
the valves can be used in combination with the safety barrier that meets the following conditions. (the valves can be used with insulation barrier that does not need type A ground.)
the barrier used in combination with the valves should be the one that has passed equipment qualification tests for a barrier and that meets the following conditions.
Safety retention voltage
Maximum voltage of a intrinsic safety circuit
Less than 29.4V
Maximum current of a intrinsic safety circuit
Less than 93.8mA
Electric power of a intrinsic safety circuit
Less than 0.689W
Performance classification / Group
Performance classification
ia
Group
ⅡB or ⅡC
Allowable inductance (Lo) and capacitance (Co) for an intrinsic safety circuit and relationship between inductance (Lo) and capacitance (Cw) for external connections to the intrinsic safety circuit
Allowable inductance of a intrinsic safety circuit: Lo≧Li+Lw(mH)