Product Main

Quick Details

Model Number: CSA-B51-03
Brand Name: Anderson
Place of Origin: United States

Specifications

Anderson's newest sanitary pressure transmitter improves upon the solid performance of the standard HA by allowing the device to be autoclaved in place. Improved enclosure integrity and tighter accuracy and stability will make this the transmitter of choice in both autoclave and critical applications.

 Response Time:   200 uSec

Output:   4-20 mA DC, 2 wire

Accuracy:   !à 0.4% of full scal

Repeatability:   !à 0.2% of full scal

Hysteresis:   !à 0.10% of full scale

Anderson Clean Process Measurement Fittings

Sanitary pressure gauges and transmitters that can be installed on lines as small as 1/2" without the need for adapters or reducers, without creating pockets or "dead legs", and without sacrificing performance.

Anderson's newest sanitary pressure transmitter is specifically designed for critical measurements in fractional size lines. This product replaces the two piece fractional transmitter with a very compact, single piece transmitter.

Excitation:

10-40 VDC (Absolute), 24 VDC Nominal regulated or unregulated.

Output:

4-20 mA DC, 2 wire with non-interrupting circuit verification test points

Loop Resistance:

0-700 ohms at 24 VDC

Wiring Connection:

16 AWG max.; Screw Terminal; Accessible via removable screw cap conduit housing

Recommended Cable:

22-24 AWG, foil shielded, and PVC coated.(3/16 - 1/4 OD insulation)

Accuracy: 0.5% of Full Scale

Repeatability: 0.3% of full scale

Hysteresis: 0.25% of full scale

Linearity:0.10% of full scale

Stability:.25% of calibrated range/6 months

Storage Temperature:-40 to 149F (-40C to 65C)

Process Temperature Limits: 30 to 300F (-1C to 149?C)

(Horizontal Mount recommended over 275F)

Ambient Temperature Limits:40 to 120 F (4 to 49?C)

Effect of Temperature Change: 0.1 psig/10F typical

Over-Range Rating:2 times base range

Wetted Parts:316L stainless steel electropolished  (R  max. = 8 microinches, .2 microns)a

Housing Material:304 Stainless Steel

Zero and Span Adjustments: 10% of range

Mounting:Direct connection

16. Anderson HH Compact Pressure Transmitter CSA-B51-03 CRN# CSAOF9754.5R1

A 3-A compliant stainless steel diaphragmed version of our ultra low profile series. The HH is ideal for preassembled skids destined for the wet environments found in dairies, beverage and food processing facilities.

Excitation:   10-40 VDC (Absolute), 24 VDC Nominal  

Response Time:   200 uSec

    regulated or unregulated

Wetted Parts:   316L stainless steel

Output:   4-20 mA DC, 2 wire with non-interrupting  

    (Ra max. = 25 microinches, 0.6 microns)

Housing Material:  304 stainless steel

Loop Resistance:  0-700 ohms at 24 VDC

Span Adjustment:   !à 50% of range, except 15 psi !à1

Wiring Connection:  5 pin M12 Quick Disconnect Receptacle

Zero Adjustment:  10%

Recommended Cable:

Mounting:   Direct connection

    (4-8mm (0.16-0.31!±) cable sheath OD)

Standards:    Designed and manufactured to sound 

Accuracy:   !à 0.5% of full scal

    engineering practices in accordance with 

Repeatability:   !à 0.3% of full scal

    Article 3.3 of the PED 97/23/EC

Designed specifically for the needs of the Life Science market the MPP Pharmaceutical Series Pressure Transmitter provides state of the art performance in a superior sanitary package. Developed from Anderson's Next Generation Modular Platform the MPP delivers class leading performance while providing the benefits of a modular architecture, assembled in an ASME –BPE compliant design. The MPP is 24 v DC, Loop powered (2 wire) 4 – 20 mA output with HART 7.0

Hysteresis:   !à 0.10% of full scale

    NEMA 4X

Linearity:   !à0.10% of full scal

    IP66 & IP69K

Stability:   !à0.30% of calibrated range/6 month

    CSA B51-03

Storage Temperature:  -40!aC to 65!aC (-40!aF to 149

    3-A

Process Temperature Limits:  -1!aC to 149!aC (30!aF to 300

    CE (pending)

     (Horizontal mount recommended over  

Warranty:   1 year

    135!aC (275!aF

Ambient Temperature Limits: -18!aC to 49!aC (0!aF to 120

Effect of Temperature Change:!à 0.1 psig/5.5!aC (10!aF) typi

A member of Anderson's Next Generation Platform, the MPF Food/Beverage/Dairy pressure transmitter provides a fully modular design, internal diagnostic display, and superior environmental protection. State of the Art performance delivers accuracy to 0.1% of calibrated range with class leading stability. Broadly configurable, 24 v DC,Loop powered (2 wire) 4 – 20 mA output with available HART 7.0

Performance mechanical & electrical:

Calibrated Accuracy:   !à 0.10% of calibrated range up to 5:1 turndow

  (!à 0.15% if over 5:1 turndown

Repeatability:   0.05% as calibrated

Long Term Stability:   0.2% URL for 2 years

Process Temperature Effect:  !à 0.1 psi/10!aF (5.5!aC) typi

Ambient Temperature Effect:  !à 0.1 psi/10!aF (5.5!aC) typi

Over-Range Capability:   30/100/500 psi stem:

    1.5x URL no effect on accuracy

    2x URL to failure

  1000 psi stem:

    1.1x URL no effect on accuracy

    1.25x URL to failure

Response Time:   <100 Milliseconds

Sampling Rate:   <50 Milliseconds

Damping:   Menu adjustable

Range Turndown Capability:  10 to 1 turn down from URL

Ranges, URL (PSI):   30,100,500,1K gauge and compound 30,100,500 absolute

Ranges, URL (BAR):   2,7,35,70 gauge and compound 2,7,35 absolute

enVironmental:

Process Temperature Limits:  0 to 350!aF (-18 to 177!aC) with ambient temperatures to 140!aF (60!aC) and 0 to 330!aF (0 to 7

  with ambient temperatures to 160!aF (71!a

Ambient Temperature Limits:  32 to 160!aF (0 to 71!a

Enclosure Protection:  NEMA 4X & IP66

  IP69K(when equipped with QDR)

construction / finish:

Non-Product Contact Plastic: polycarbonate threaded cap. Delrin atmospheric vent

Wiring Connection:   M16 x 1.5 threaded housing electrical entry

  Equipped with:

    Standard - replaceable M12 5 pin Eurofast QDR

    Optional - M16 Cord Grip, M16 x 1.5" NPTF adaptor

oPerational:

Output:   2 wire user selectable 4-20 mA DC or  20-4 mA

Internal Display:   4 digit LED nominally displays loop current. Process variable selectable - PSI or BAR.

Loop Resistance:   0-300 ohms at 24 VDC

Electrical Connection:   screw terminals with a conductor cross section range of 14-26 AWG

Recommended Cable:   Anderson shielded molded cordset,  alternatively: 22-24 AWG, foil shielded, 0.17 - 0.26!± Cable Sheath

Operating Voltage:   18-36 VDC (24 VDC Nominal regulated or unregulated)

Zero Adjustment:   one touch

Re-Span:     With switch through user interface & with or without a reference pressure source

aPProVals and documentation

Compliance:    Compliant with the Pressure Equipment Directive relative to Sound Engineering Practices(PED)

   

CSA-B51-03

     CRN# CSAOF9754.5R1

Warranty:  2 years

17. Anderson SR Pressure Transmitter

The Anderson SR offers not only a new low profile design, but may be ordered with built-in LCD indication.

Excitation:9-32 VDC (Absolute), 24 VDC Nominal, regulated or

unregulated

14-37 VDC (Absolute) with display

Output:4-20 mA DC

Loop Resistance:0-750 ohms at 24 VDC

0-1050 ohms at 30 VDC

Indication:Optional, 3 1/2 digit, .5" high LCD, cap mounted

Accuracy: 0.5% of span, full scale, for standard ranges, ranges

below 0-50 psig

1% full scale; all compound and psia ranges,

1.5% full scale

Over-Range Rating:2 times base range

Stability:  0.3% of calibrated range/6 months

Storage Temperate:-40 to 150?F (-40 to 65?C)

Zero and Span Adjustment:  10% of range

Repeatability:  .3%

Hysteresis:  .2%

Process Temp. Range:20? to 225?F (up to 300?F if horizontal mount)

Process Temp. Effect:Less than 0,2% of full scale output/10?F change

Ambient Temp. Operating Range:0? to 120?F (-17.8? to 48.9?C)

Storage Temperature:-40? to 149?C (-40? to 65?C)

Mounting:Direct connection

Housing Material:304 Stainless Steel

Wetted Parts:316L Stainless Steel standard; Hasteloy "C" diaphragm

optional

Surface Finish (wetted parts):R  = 25 microinches (.6 microns) for standard finish;

a

R  max = 8 microinches (.2 microns) for electropolished

a

fittings (specify when ordering)

Recommended Cable:18-24 AWG, foil shielded, and PVC coated.

(3/16" - 1/4" O.D. insulation)

Wiring Connection:Screw Terminal; Accessible via removable screw cap

conduit housing

The Anderson SV Pharmaceutical Series Pressure Transmitter offers not only a new low profile design, but may be ordered with built-in LCD indication.

Excitation:9-32 VDC (Absolute), 24 VDC Nominal, regulated or

unregulated

14-37 VDC (Absolute) with display

Output:4-20 mA DC

Loop Resistance:0-750 ohms at 24 VDC

0-1050 ohms at 30 VDC

Indication:Optional, 3 1/2 digit, .5" high LCD, cap mounted

Accuracy: .5% of span, full scale, (for standard ranges)

(Includes Hysteresis,  1.0% of span, full scale, (for ranges below 0-50 psig,

Repeatability, and Linearity)and all compound/psia ranges)

Over-Range Rating:2 times base range

Stability:  0.3% of calibrated range/6 months

Storage Temperate:-40 to 150F (-40 to 65?C)

Zero and Span Adjustment:  10% of range

Repeatability:  .3%

Hysteresis:  .1%

Linearity ? .1%

-6.7 to 135?C (up to 163C if horizontal mount)

Process Temp. Range:20 to 275?F (up to 325F if horizontal mount)

Process Temp. Effect:Less than 0.2% of full scale output/10F change

Ambient Temp. Operating Range:-17.8 to 48.9C (0 to 120F)

Storage Temperature:-40 to 65C (-40 to 149F)

Mounting:Direct connection

Housing Material:316 Stainless Steel

Wetted Parts:316L Stainless Steel standard; Hasteloy "C" diaphragm

optional

Surface Finish (wetted parts):R

 max = 8 microinches (.2 microns) electropolished

a

Recommended Cable:18-24 AWG, foil shielded, and PVC coated.

(3/16" - 1/4" O.D. insulation)

Wiring Connection:Screw Terminal; Accessible via removable screw cap

conduit housing

The Anderson "T" series pressure transmitter is a microprocessor-based sensor specifically designed for sanitary fluid process applications in the pharmaceutical and biotechnology industries.

Ranges:

Rangeability (Turn-down):

Over Pressure Limit: Accuracy*

Over Pressure Output:  Sensor Style 1 & 2: Above 110% of  

  calibrated range - 3.8 mA

  pressure output

Mechanical Trim Adjustments: Repeatability:

Hysteresis:

Output:

Linearity (BFSL):

Stability:

Power Supply:

Indication:     Optional, cap-mounted, LCD Indication  

max  = 8    Wetted Material Surface Finish:      Electropolished to R

a

Temperature Limits (Process):

Wetted Material:

Housing Material:

 

Actuating Fill:

Hazardous Locations Compliance:

Housing Ratings:

  UL Compliance with Class 1,  Div. 1, Groups A thru D  

Anderson TP HART/SMART Pharma-Series Pressure Transmitter