Model Number: | MFLD |
---|---|
Brand Name: | KFKC |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
Works MFI-type plug-in electromagnetic flowmeter is based on Faraday's law of electromagnetic induction. In the electromagnetic flowmeter, the conductive medium corresponds to the measuring tube of the conductive Faraday test rods of the upper and lower ends of the two electromagnetic coils generating a constant magnetic field. When flows through the conductive medium, the induced voltage is generated. Two electrodes induced voltage generated inside the pipe measured. Measured by a non-conductive pipe liner (rubber, Teflon, etc.) and the measuring electrode and the fluid to achieve electromagnetic isolation.
Product Features
1, the measurement is not affected by fluid density, viscosity, temperature, pressure and electrical conductivity change;
2, the measuring tube unimpeded flow of parts, no pressure drop, straight pipe requirements are lower;
3, Series nominal diameter DN15 ~ DN3000. Sensor lining and electrode materials have a variety of options;
4, the converter uses a novel excitation mode, low power consumption, zero stability, high accuracy. Flow range of up to 1500:1;
5, the converter can be composed of a body with a sensor or body;
6, the converter uses 16 high-performance microprocessors, 2x16LCD display, convenient parameter setting, programming and reliable;
7, two-way flow measurement system, built three totalizer: Forward total, and the total amount of the difference between the reverse; may be displayed. Zhuang, regurgitation, and has a variety of output: current, pulse, digital communications, HART;
8, the converter using surface mount technology (SMT), a self-test and self-diagnosis function