Model Number: | TDS-100F |
---|---|
Brand Name: | teren |
Place of Origin: | China (Mainland) |
Power Supply: | AC: 110V/220V or DC: 8VDC-36VDC |
Pipe Size: | 1"~240"(DN30~DN6000mm) |
Communication Interface: | RS-232, RS485 |
Velocity: | 0.5s |
Liquid Types: | Virtually all liquids |
Repeatability: | Better than 1% |
Weight: | TR-UFM-100F:5lb(2.5kg) |
Protection Class: | IP65(NEMA 4X) |
Pipe Suspension concentration: | <1%, particle size smaller than 75um |
Quick Details
Specifications
Wall mount ultrasonic water flow meter factory
The TDS-100F is carefully designed so that their operation is simple and easy. The unique clamp-on fixture design makes the installation very simpleand no special skills or tools are required.
Due to the nonintrusive nature of the technology, there is nopressure drop, no moving parts, no leaks, no risk of contamination, no risk of corrosion, no pressure dependency.
Technical Parameter:
Repeatability |
Better than 1% |
Accuracy |
Better than ±1%for velocity above 0.6ft/s |
Velocity |
0.5s |
Display |
LCD with backlight 2*20leters |
Units |
English(U.S) or metric |
Signal Outputs |
Current output: 4-20mA or 0-20mA. Impedance 0-1k. Accuracy 0.1% |
Signal Inputs |
5 channel analog signal inputs |
Recording |
Automatically record the following information: The totalizer data of the last 64days/64month/64years; The time and corresponding flow rate of the last 64 times of power on and off events. Allow manual or automatic flow loss compensation;the instrument working status of the last 64days |
Communication Interface |
RS-232,RS-485(optional); GPRS/GSM module for networking, remote monitoring and remote control(for model UFM-100FNB only) |
Enclosure |
Protection Class: IP65(NEMA 4X); Explosive Proof Class: ExdⅡBT4(for model UFM-100F2B only) |
Liquid Types |
Virtually all commonly used liquids(full pipe) |
Pipe Size |
1"~240"(DN30~DN6000mm) |
Pipe Material |
All metals, most plastics, fiber glass, etc. Allow pipe liner |
Cable |
Shielded transducer cable. Standard length 15'(5m). Can be extended to 1640'(500m). |
Power |
AC: 110V/220V or DC: 8VDC-36VDC |
Transducer Installation:
Features
* No pressure drop
* No risk of contamination
* No pressure denpendency
* Operation is simple and easy
* High accuracy measuring
We use wooden case to pack electromagnetic flow meter if the norminal size bigger than DN220mm. We have eatalished nice relationships with so many expresses,forwarders,and shipping companies. So, we can get a cheaper unit price for you.
We Can Offer:
* Competitive Price
* Free OEM service,makes the products to be yours only.
* Design and printing, we offer you product's designing and handbook's revising.
* Online service and inquiry, we promise to reply any of your information within 12 hours.
* R&D, customers provide their own idea or option, we could change the appearance, logo, color, program, output.etc
* Technical support, we offer free support whatever you know them well or not, we will solve your measuring problem all products' life.
* Better After Sale,we promise to repair and maintain the products for free in 2 years if there is any natural damage.
Teren instruments was established in 2007, main focus on running of instruments, main cover ultrasonic flow meter, ultrasonic level meter, ultrasonic water meter, electromagnetic, turbine, vortex, oval gear flow meter, radar Level meter and other series industry instruments.
we have overcame many technical difficulties on fluid analysis under the guidance of Professor Jing Xian Wang , such as " High frequency Multiple-pulse Ultrasonic launch drive" ," Hydraulic pipeline efficient circulation Washing Device" and so on, meanwhile, Jing Xian Wang professor have got several patents, like ZK-120.
Our products gain acceptance from users in domestic and aboard for years. We are reliable, experienced and trustworthy.