Type: | Other Waterproofing Materials |
---|---|
Model Number: | PCC 501 |
Brand Name: | Yuhong |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
Where to use
Undergrounds concrete constructions;
Subways and tunnels;
Sewage pools, water pools and sewers;
Other pools, penstocks and walls.
Advantages
Excellent infiltration capacity to penetrate to the concrete surfaces above 5 cm;
Contains various active chemical materials to ensure crystal growth and make concrete compact;
Excellent impermeability of concrete substrate to resist hydraulic pressure above 120 meters height for a long time;
Waterproof layer are not afraid of bumps, can withstand a certain degree of external force;
Durable and high resistance for harmful chemical erosions;
Can be safely used for drinking water constructions without poisonous or harmful materials;
Self healing ability for no more than 0.4 mm tiny fissures in concrete interior;
Can brush decorating materials, such as ash, paint directly on waterproof layer.
Standards
GB18445-2001
Typical properties
Item |
Requirement |
|
Invariability |
Pass |
|
Setting time |
Initial setting time, min ≥ |
20 |
Final setting time, h ≤ |
24 |
|
Bending strength, MPa ≥ |
7 d |
2.80 |
28 d |
3.50 |
|
Compressive strength, MPa ≥ |
7 d |
12.0 |
28 d |
18.0 |
|
Bonding strength on wet substrate, MPa ≥ |
1.0 |
|
Resistance to penetration (28 d), MPa ≥ |
1.2 |
|
Second resistance to penetration (56 d), MPa ≥ |
0.8 |
|
Ratio of seepage pressure(28 d), % ≥ |
300 |
Packaging
PCC-501A is sealed in 25kg plastic casks and transported in wooden cases. Each wooden case can be contained 36 casks of PCC-501A.
Storage
PCC-501A materialshouldbestored for 1 year at dry and well-ventilated places.
Transportation
PCC-501A is transported according to non dangerous goods rules.
Application System
Constructive System
The system is basically consisted of substrate, additional layer and waterproof coated membrane.
Coverage
1.0-1.2kg per m2 gives dft 0.8mm minimum. Coverage may vary with the substrate condition during application.
Application Method
Surface preparation
Surfaces should be stable, clean, smooth, without obvious water and free from any dusts, oil or loose particles. Before painting, surfaces must be fully wet to make PCC coatings spay into concrete.
Brush constructive method
Mixing: Mix 1kg with approximately 0.25 -0.4 kg of water, depending on required consistency; Put water into containers at first, then add PCC powders and mix 5 minutes with machines.
Painting: Use hard brush to paint on the surface equally for 2 or 3 times. It must be painted again after fully dry. If the first painting shows dry and white, surfaces need to be re-painted.
Powder-cover constructive method
Put 1kg powder on each square meters concrete surfaces equally where are not fully dry, then use wood float, polisher to press powder into concrete and do calendaring until achieve requirements.
Curing
Spraying water, covering wet materials and painting membrane curing liquid can be protecting methods. The protection period must more than 72 hours.