Tower/Rack online single phrase  UPS for telecom with cold start function

High Frequency Online UPS Rack Tower Star Series RT 1K-10KVA(1Ph in/1Ph out)


Key Features:
1:Rack Mount - Tower Convertible    
2:True on-line double conversion technology with advanced microprocessor control
3:Active Input Power Factor Correction (PFC), UPS can correct the input power factor. Under full load, the input power factor can reach over 0.95 so that the electric environment of the users will not be polluted.    

4:Full automatic and silent operation
5:It sdopts standard frame structure design. The structure is compact.
6:Sine wave output no matters in AC mode or battery mode can provide sine wave power source with low distortion. It provides the best power source guarantee for the load equipments for users.
7:Site wiring fault warning
8:Diverse options of accessories, intelligent management

9:Compact size for convenient use and storage
10:It has voltage breakthrough protection and strong anti-interference function.  


Applications
Alarm Systems,Marine Equipment,Cable Television,Medical Equipment,Communications Equipment,Telecommunications Systems, telecom, bank, hospital, bureau, traffic, public security, ATM etc.


Technical Specification


MODEL(RT Series) RT1K RT1KL RT2K RT2KL RT3K RT3KL RT6KL RT10KL
Input Rated Capacity 1KVA/800W 2KVA/1600W 3KVA/2400W 6KVA/4800W 10KVA/8000W
Voltage 90 ± 5 ~290 ± 5Vac 176 ~ 276Vac
Current 6A(max) 12A(max) 16A(max) 31A(max) 60A(max)
Frequency 40 ~ 60 Hz
Power factor Conformity EN60555-2(≥0.95) ≥0.95(MAX)
Output Voltage 220Vac ( 1 ± 2%) 220Vac ( 1 ± 1%)
Current 4.55A 9.1A 13.6A 27.3A 54A
Frequency (50 ± 2)Hz (50 ± 1)Hz
Power Factor 0.8 lag
Waveform Sine Wave
Waveform  Linear ≤ 7% when RCD 100% loading (Non-line)
Distortion Linear ≤ 3% when RCD 100% loading (line)
Overload protection 105%<  <125% → 50s 100%-125%, 1 minutes to
125%<  <150% → 25s  transfer to bypass; >150%,
>150% →  300s  100ms to transfer to bypass
Transfer Time Oms
Type of Battery Sealed lead acid maintenance-free
External Battery Voltage 3x7 Ah 36Vdc 6x7 Ah 72Vdc 8x7 Ah 96Vdc 192Vdc/240Vdc
Working  Operating 0-40℃
Environment  Temperatures(℃)

Relative  0-90(%)

Temperature(℃)

Altitude <1500m
Communication 9pin D trpe comector (RS232)
Size (WXDXH) mm 482x450x88 Standard Type (3U): 482x680x132.5 482x680x132.5
Long Backup Type (2U): 482x450x88
Weight (kg) 14.5 8 22 9.8 26 9.8 20 25