Product Main

Quick Details

Application: Networking
Type: On-line
Output Voltage: 220/230/240vac
Protection: Overcurrent
Phase: Single Phase
Model Number: Rack Tower Star Series RT
Brand Name: UPSEN
Place of Origin: China (Mainland)
THDI: <3%
Business Type: Manufacturer
Input Frequency: 50/60Hz
Transfer Time: Zero Conversion

Specifications

1K-10KVA Tower & Rack Mount double convertable online UPS for Medical Systems with IGBT
High Frequency Online UPS Rack Tower Star Series RT 1K-10KVA(1Ph in/1Ph out)

Key Features:
1:Rack Mount - Tower Convertible    
2.Rotate LCD Display  
3:It provides the best power source guarantee for the load equipments for users.

4:Rack-Tower convertible of all portable ups  

5:Sine wave output no matters in AC mode or battery mode can provide sine wave power source with low distortion. 

6.It sdopts standard frame structure design. The structure is compact.

7:It has voltage breakthrough protection and strong anti-interference function. 

8:Comprehensive protection for the total unit

9:Zero delay: when the utility power is cut off or recover, there is absolutely no time between the transfer of AC mode and battery mode. It effectively ensures the reliability of load operation.

10:friendly and intuitive interface, full protection for the equipment

11:Active Input Power Factor Correction (PFC), UPS can correct the input power factor. Under full load, the input power factor can reach over 0.95 so that the electric environment of the users will not be polluted. 


Applications
Servers, Military,Medical Systems,Network sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM etc.


Technical Specification


MODEL(RT Series) RT1K RT1KL RT2K RT2KL RT3K RT3KL RT6KL RT10KL
Input Rated Capacity 1KVA/800W 2KVA/1600W 3KVA/2400W 6KVA/4800W 10KVA/8000W
Voltage 90 ± 5 ~290 ± 5Vac 176 ~ 276Vac
Current 6A(max) 12A(max) 16A(max) 31A(max) 60A(max)
Frequency 40 ~ 60 Hz
Power factor Conformity EN60555-2(≥0.95) ≥0.95(MAX)
Output Voltage 220Vac ( 1 ± 2%) 220Vac ( 1 ± 1%)
Current 4.55A 9.1A 13.6A 27.3A 54A
Frequency (50 ± 2)Hz (50 ± 1)Hz
Power Factor 0.8 lag
Waveform Sine Wave
Waveform  Linear ≤ 7% when RCD 100% loading (Non-line)
Distortion Linear ≤ 3% when RCD 100% loading (line)
Overload protection 105%<  <125% → 50s 100%-125%, 1 minutes to
125%<  <150% → 25s  transfer to bypass; >150%,
>150% →  300s  100ms to transfer to bypass
Transfer Time Oms
Type of Battery Sealed lead acid maintenance-free
External Battery Voltage 3x7 Ah 36Vdc 6x7 Ah 72Vdc 8x7 Ah 96Vdc 192Vdc/240Vdc
Working  Operating 0-40℃
Environment  Temperatures(℃)

Relative  0-90(%)

Temperature(℃)

Altitude <1500m
Communication 9pin D trpe comector (RS232)
Size (WXDXH) mm 482x450x88 Standard Type (3U): 482x680x132.5 482x680x132.5
Long Backup Type (2U): 482x450x88
Weight (kg) 14.5 8 22 9.8 26 9.8 20 25