Model Number: | LUGB-A/B/C |
---|---|
Brand Name: | U-ideal |
Place of Origin: | China (Mainland) |
Sensor: | Tube/Flange |
Type: | Vortex Flow Meter |
Size:: | Dn15~Dn300 |
Measuring Media: | Gas |
Signal: | Modbus RS485, Hart, 4~20mA, Pulse |
Quick Details
Specifications
Our flow meters are calibrated by special testbed, can assure you good accuracy.
Our flowmeter are done with actual good material, don't mix any bad matrial.
WE do those all hope have long business relationship with you.
2. Vortex precession flowmeter
Vortex precession flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using a single meter
? Measures most gases, liquids and steam without the need to recalibrate
? Cost effective, accurate and reliable meter for volumetric and mass flow measurement
? Remote monitoring and integration to DCS using HARTand Modbus communication protocols
? Ideal for high temperature and high velocity steam
? Power Generation steam applications
? Industrial HVAC, district energy management
? Commercial building, campus and facility energy management
? Oil & gas location of natural gas
3. Electromagnetic Flow Meter
Electromagnetic flowmeter is a kind of high performance, high reliability of the flowmeter. Widely used in petroleum, chemical to measure water, sewage, acid, alkali, salt solution or volume flow of liquid-solid two-phase fluid conductive medium.
4. Coriolis Mass flow meter
Measuring the Mass flow rate + volume flow rate + density measurement +temperature measurement +calculated variables (e.g. fluid concentrations) at the same time.
Application: liquid and gas mass flow measurement.
Our flowmeter are done with actual good material, don't mix any bad matrial.
WE do those all hope have long business relationship with you.
2. Vortex precession flowmeter
Vortex precession flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using a single meter
? Measures most gases, liquids and steam without the need to recalibrate
? Cost effective, accurate and reliable meter for volumetric and mass flow measurement
? Remote monitoring and integration to DCS using HARTand Modbus communication protocols
? Ideal for high temperature and high velocity steam
? Power Generation steam applications
? Industrial HVAC, district energy management
? Commercial building, campus and facility energy management
? Oil & gas location of natural gas
3. Electromagnetic Flow Meter
Electromagnetic flowmeter is a kind of high performance, high reliability of the flowmeter. Widely used in petroleum, chemical to measure water, sewage, acid, alkali, salt solution or volume flow of liquid-solid two-phase fluid conductive medium.
4. Coriolis Mass flow meter
Measuring the Mass flow rate + volume flow rate + density measurement +temperature measurement +calculated variables (e.g. fluid concentrations) at the same time.
Application: liquid and gas mass flow measurement.
5. Oval gear flowmeter
6. Ultrasonic flowmeter
Ultrasonic flow meter is designed to measure the velocity of liquid within a closed conduit. It uses the well-known transit-time measurement principle, plus our proprietary signal processing and ultrasonic transcribing technologies.
7. Swirl Flow Meter
As the vortex flow meter, the swirl flow meter is based on the principle of frequency measurement. The system has a freely configurable, LCD display for the actual flow rate and tantalization. Settings can be changed directly via 3 push buttons. Additional to the 4-20mA analog signal a freely configurable switching output is already available. This can be used universally as pulse output, high-low alarms or for system supervision. Swirl flow meter is available as compact for remote design with 10 m length cable.
Built-in pressure, temperature, flow sensors, security, high performance, compact structure, beautiful shape.
8. Sight Glass flow Meter
The cheap flow meter which measure and indicate the flow rate directly.
Application: liquid and air flow rate measurement.
Oval Gear Positive Displacement Flowmeters
Oval wheel flow-meters(High Viscosity Oval Gear Flowmeters)
Mechanical fuel flow meter & Oil oval flow meter & oval gear flow meter
Oval Gear positive displacement meters, which are ideal for highly viscous liquids in applications where accuracy and repeatability are critical.
6. Ultrasonic flowmeter
Ultrasonic flow meter is designed to measure the velocity of liquid within a closed conduit. It uses the well-known transit-time measurement principle, plus our proprietary signal processing and ultrasonic transcribing technologies.
7. Swirl Flow Meter
As the vortex flow meter, the swirl flow meter is based on the principle of frequency measurement. The system has a freely configurable, LCD display for the actual flow rate and tantalization. Settings can be changed directly via 3 push buttons. Additional to the 4-20mA analog signal a freely configurable switching output is already available. This can be used universally as pulse output, high-low alarms or for system supervision. Swirl flow meter is available as compact for remote design with 10 m length cable.
Built-in pressure, temperature, flow sensors, security, high performance, compact structure, beautiful shape.
8. Sight Glass flow Meter
The cheap flow meter which measure and indicate the flow rate directly.
Application: liquid and air flow rate measurement.
Our other related products: level gauges, flow meters, pressure transmitters, indicators, industrial system.
Welcome to contact if have enquiry.
Turbine flowmeter diameter and connection |
4,6,10,15,20,25,32,40 apply thread connection |
(15,20,25,32,40)50,65,80,100,125,150,200 apply flange connection | |
Accuracy class | ±1%R,±0.5% |
Measuring scale ratio | 1:10;1:15;1:20 |
Material | 304 stainless steel,316(L)stainless steel and others |
Fluid temperature | -120~+120oC |
Environment | Temperature-10~+55oC,relative humidity5%~90%,air pressure86~106Kpa |
Output signal | Impulse signal,low level≤0.8V high level ≥8V |
Power supply | +12VDC,+24VDC(selective) |
Signal transmission line | STVPV3*0.3(Three line system)or 2*0.3(2-line system) |
Transmission distant | ≤1000m |
Signal wire connection | Inner thread M20*1.5 |
Explosion proof class | ExdIIBT6 |
Protection class | IP65 |
|
Oval Gear Flowmeter Precision:<±0.5% Material: cast steel/stainless steel/cast iron Optional: Pulse output; reset function NP:1.6Mpa/2.5Mpa/4Mpa Temperature:-40~+160oC |
|
Rotary Piston Flowmeter Wide Flux---:1L/H-16000L/H Optimized structure---: No flow adjustment is required. Measuring Medium---: Petro, Diesel oil, Diesel oil, Distilled water, Juice, Chemical reagent etc. Safety---:Flow through the meter continues even when piston was stuck by impurity. High precision: Up to 0.3% Self-lubricant, high precision, high reliability, low noise, smooth running, easy maintenance |
|
Wet-test(drum-type) gas meter Applications & User Benefits Wet-test (drum-type) gas flow meters are used universally to measure and record gas volume and gas flow rate for many industrial, petroleum and chemical processes; environmental; pilot plant or test; controlled chamber; laboratory and research applications. Wet-test meters consistently provide the highest accuracy and precision even at the lowest gas flows with inert or the most aggressive gases |
|
Liquid roots flow meter Accuracy: ±0.5%;±0.2% Material : cast steel/stainless steel/cast iron Optional: pulse output; reset function Normal pressure:1.6Mpa/0.6Mpa Temperature:-10~+60 oC Rotors never touch each other and therefore are not subject to wear. More over double case construction allows to maintain the measuring unit Without removing the entire PD flowmeter form the line. |
|
E-F Double rotator flow meter Applies to low viscosity oil, light oil, heavy oil, crude oil with sand and water, liquid from low viscosity to high viscosity. Max. flow is 2 times larger than normal flowmeter. Long life, high accuracy and reliability. Minimal pressure loss. 1000 meters of cable for long distance output. pulse output N=0.1L(a pulse for 1N), for direct connection with computer networking. An explosion of the Ia II CT6(intrinsic safety type); flameproof d II BT6(flameproof); protection IP56. |