Model Number: | FS-JS4464616 |
---|---|
Brand Name: | FOREVER |
Place of Origin: | China (Mainland) |
Colour: | White,Blue etc. |
Usage: | Warehouse, Temporary Offices, Workshop |
Quick Details
Specifications
TECHNICAL DETAILS of Light Steel Structure Buildings:
1. Wind Load, Snow Load, Earthquake and Rainfall
2. Length, Width, Eave Height and Roof Slope
3. Single Floor or Multi-floor
4. Clear Span or Multi-span
5. Requirements on the brick wall
6. Requirements on the roof and wall materials
7. Requirements on the type & quantity of window and door
8. Requirements on the natural lighting & ventilation system
MAIN STEEL PART of Steel Workshop
1. H section steel columns, beams and wind-proof columns
2. With treatment of one time red-oxide primer painting and two times grey facing painting
SECONDARY STEEL PART of Steel Structure Warehouse
1. Roof & Wall C/Z Purlin
2. Tie Bar: φ 89*3.0
3. Roof Support & Support between Columns: φ 20
4. Bracing Bar: φ 12
5. Knee Bracing: Angle Steel
ROOF & WALL CLADDING
1. Roof & Wall Corrugated Single Steel Sheet: 0.3mm-0.6mm
2. Roof & Wall Sandwich Panel Insulated with EPS Foam, Glass wool, Rock wool and PU: 50mm-150mm
3. Transparent Sheet (FRP): 1.0mm-2.0mm
4. Flashings: Made by Color-coated Corrugated Steel Sheet
WINDOW & DOOR
1. Window: PVC Window or Aluminum-alloy Window
2. Door: Sliding Door or Roll-up Door
FASTENERS
High-strength Bolt; Common Bolt and Nut; Self-tapping Screws; Foundation Bolt and Nut, ETC
1. Wind Load, Snow Load, Earthquake and Rainfall
2. Length, Width, Eave Height and Roof Slope
3. Single Floor or Multi-floor
4. Clear Span or Multi-span
5. Requirements on the brick wall
6. Requirements on the roof and wall materials
7. Requirements on the type & quantity of window and door
8. Requirements on the natural lighting & ventilation system
MAIN STEEL PART of Steel Workshop
1. H section steel columns, beams and wind-proof columns
2. With treatment of one time red-oxide primer painting and two times grey facing painting
SECONDARY STEEL PART of Steel Structure Warehouse
1. Roof & Wall C/Z Purlin
2. Tie Bar: φ 89*3.0
3. Roof Support & Support between Columns: φ 20
4. Bracing Bar: φ 12
5. Knee Bracing: Angle Steel
ROOF & WALL CLADDING
1. Roof & Wall Corrugated Single Steel Sheet: 0.3mm-0.6mm
2. Roof & Wall Sandwich Panel Insulated with EPS Foam, Glass wool, Rock wool and PU: 50mm-150mm
3. Transparent Sheet (FRP): 1.0mm-2.0mm
4. Flashings: Made by Color-coated Corrugated Steel Sheet
WINDOW & DOOR
1. Window: PVC Window or Aluminum-alloy Window
2. Door: Sliding Door or Roll-up Door
FASTENERS
High-strength Bolt; Common Bolt and Nut; Self-tapping Screws; Foundation Bolt and Nut, ETC