Product Main

Quick Details

Model Number: UIDM
Brand Name: U-ideal
Place of Origin: China (Mainland)
Feature: Low Temperature Resistant
Standard Pressure: Pn1.0MPa~40MPa
Connecting Method: Flange, Thread
Size: Dn10~Dn500
Production Process: Normal Wirewound

Specifications

PTFE anti-corrosion type liquid level transmitter, all the wetted parts are made of PTFE material, have characters of high temperature resistance, corrosion resistance and anti clogging. And it is widely used in any liquid level measurement of atmospheric pressure (except for material corrode PTFE).
1. Characteristics
? Good stability, high precision, high temperature resistant, corrosion resistant, anti clogging.
? Directly input to the measured medium, installation and usage are very convenient.
? Compact structure, no moving parts, high reliability, long service life.
? It is widely used in any liquid level measurement (except for material corrode PTFE).
? Can measure from the water, oil, acid, alkali, salt to larger paste viscosity fluid with high precision measurement, and are affected by foaming of the measured medium, deposition, the influence of the electric property.
? Have reverse polarity power supply and overload current protection function.

2. Technical Parameters
? Measuring range: 0 ~ 30 meters.
? Output signal: 4 ~ 20 mA/DC.
? Power supply: 24V+- 5 VDC.
? Accurate rating: 0.5%FS.
? Long term stability: Plus or minus 0.2% FS/year
? Medium temperature: - 50 ~ 100o C( state of not clotting)
? High temperature type: -50~200~300o C( state of not clotting)

Flange Connection type

Features: Flange connection LCD type input level sensor use diffusion silicon piezoresistive core body, SS316 meter, Flange: SS304. Explosion-proof shell, are widely used in river, open channel, water reservoir and water tower etc. Liquid level measurement and controlling.

Main technique parameters:
Measuring medium: Water and oil
Pressure type: Meter press, Absolute Pressure (default meter pressure)
Measure range: 0 ~ 300 m
Comprehensive accuracy: 0.1% FS
Output signals: 4 ~ 20 ma (two-wire system), 0 ~ 5 v, 1 ~ 5 v, 0 ~ 10 v (three-wire system)
The power supply voltage: 12 ~ 36 VDC
Medium temperature: - 30 ~ 60 o C
Ambient temperature: - 40 ~ 85 o C
Zero temperature drift: Plus or minus 0.05% FS o C or less
The range of temperature drift, plus or minus 0.05% FS o C or less
Compensation temperature: 0 ~ 70 o C
Safety overload: 150% FS
Limit overload: 200% FS
Sampling frequency: 2 ms or less
Load capacity: (current) 250 ~ 1425 Ω , (voltage) 2 kΩ Or more
Seal level: IP68
Long-term and stable performance: 0.1% FS/year
Vibration impact: In mechanical vibration within 20 hz ~ 1000 hz frequency, output variation is less than 0.1% FS
Connection mode: Flange

Name Input Type Level Sensor
output 2-wire 2~20mA, switching alarm, LCD, Hart optional
Load 0~500
Level range H=0.1~30m(special assemble if longer than 6m)
Accuracy A:+/-5mm, B: +/-10mm, C: +/-20mm
Fluid temperature -20~150oC
Electric Power DC 24V

Model selection
UQK-B floater level transmitter
Accuracy A 5mm
B 10mm
C 20mm
structure
1 float ball diameter:45mm. H1=40mm, H2=30mm
2 76mm, H1=50mm, H2=40mm
3 125mm, H1=80mm, H2=65mm
Insallation
F flange
P angle plate bracket
S screw
A adjustable screw is optional
Other function
P pressure <0.6MPa
E explosion-proof
S Digital display