Product Main

Quick Details

Application: Networking
Type: On-line
Protection: Unbalanced Loads
Phase: Single Phase
Model Number: Green star series
Brand Name: UPSEN
Place of Origin: China (Mainland)
Application: Home
Output Capacity: Large Type
Standby UPS: Sine Wave Output UPS
Phase: Single Phase

Specifications

Double Conversion High Frequency Online UPS with Long Backup Time

 

Application
Servers, PCs, Computers,data-center critical network devices,Fax etc. Also can be applied for Sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.

 

 

Standard UPS Overview
1: Online UPS with both Standard UPS Model and Long Run UPS Model for choose
2: 1000VA 2000VA UPS with smart and compact design
3:  UPS with LCD & LED Display
4:  DC to AC UPS with Input power factor correction


UPS Key Features
True double-conversion
Output power factor 0.8
Wide input voltage (110 V - 300 V)
Converter mode available
ECO mode for energy saving
Generator compatible
Microprocessor control optimizes reliability
Input power factor correction
Charger capacity expansion to 6A for long-run models
Smart SNMP works well with either USB or RS-232 together
Comprehensive display allows easy monitoring and access of UPS status


Technical Specification


GREEN STAR ONLINE UPS SELECTION GUIDE
MODEL G1K (L) G2K (L) G3K (L)
PHASE Single phase with ground
CAPACITY 1150 VA / 800 W 2300 VA / 1600 W 3000 VA / 2400 W
INPUT
Nominal Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC
Input Voltage Range 55-145 VAC or 110-300 VAC
Frequency Range
 
40Hz  ~ 70 Hz
Power Factor >= 0.99 @ Nominal Voltage (100% load)
OUTPUT
Output Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC
Voltage Regulation ± 1%
Frequency Range (Synchronized Range) 47~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode) 50 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion <= 3 % THD (Linear Load); <= 6 % THD (Non-linear Load)
Transfer Time AC to DC Zero
Inverter to Bypass 4 ms (Typical)
Waveform (Batt. Mode) Pure Sinewave
EFFICIENCY
To AC Mode 93% 93% 93%
To Battery Mode 83% 87% 88%
BATTERY
Standard Model Battery Type 12 V / 9 AH 12 V / 7AH 12 V / 7 AH
Numbers 2 6 6
Typical Recharge Time 4 hours recover to 90% capacity
Charging Current (max.) 1.0 A
Charging Voltage 27.4VDC ± 1% 82.1 VDC ±1% 82.1 VDC ±1%
Long-run Model* Battery Type Depending on the capacity of external batteries
Numbers 3 6 8
Charging Current (max.) 1.0A/2.0A/4.0A/6.0 A
Charging Voltage 41.0VDC ± 1% 82.1 VDC ±1% 109.4VDC ±1%
INDICATORS
LCD
Load level, Battery level, AC mode,
Battery mode, Bypass mode, and Fault indicators

ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continously sounding
PHYSICAL
Standard Model Dimension, D x W x H (mm) 397 X 145 X 220 419X190X318
Net Weight (kgs) 13 26 28
Long-run Model* Dimension, D x W x H (mm) 282 x 145 x 220 397 X 145 X 220
Net Weight (kgs) 4.6 6.8 7.4
ENVIRONMENT
Humidity 20-90 % RH @ 0- 40°C (non-condensing)
Noise Level Less than 50dBA @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser

* Long-run model is only available in 200/208/220/230/240VAC systems.