Product Main

Quick Details

Type: Spray Booths
Model Number: TG-70B
Brand Name: TARGET
Place of Origin: China (Mainland)
Voltage: 220/380V
Internal Size: 6900*4000*2800 (LxWxH)
External Size: 7000*5560*3500 (LxWxH)
Power: 17KW

Specifications

Spray BoothDiesel BurnerTG-70B

Inside dimension

6900*4000*2800 (LxWxH)

Front door(mm)

3000*2700 mm(W×H)

Outside dimension

7000*5560*3500 (LxWxH)

Total Power(Kw)

17 Kw , Noise < 80db

Cabin System

Wallboard

EPS (epispastics polystyrene) colorful steel skin panel, EPS foam Density is 16kg/m3, 50mm thick, steel 0.5mm thick, compound construction, anti-flame and heat-insulation, galvanized steel roof panel.

Basement

350mm depth , Galvanized steel sheet and square steel pipe assembling, 2 rows of grid plates made by flat bar and round steel, 3 rows of diamond plates, galvanized. 2 ramps, external setting, 750 x 2000 mm ( W * L )/pc

Air Circulation System

Intake Fan

Blower Capacity: 25000m3/h

Exhaust Fan

Blower Capacity: 25000m3/h

Power: 7.5kw/pc

Power: 7.5kw/pc

Quantity: 1 pc

Quantity: 1 pc

Model: turbo fan

Model: turbo fan

Air Volume: 25000m3/h , Air flow speed in the cabin: 0.25m/s

Heating system

Burner

Italy Riello G20 Diesel Burner, 200000Kcal/h. SUS304 Stainless steel heat exchanger , argon arc welding.

Heat energy

Max Temp: 80. C, Heating Time: 4-5min(20-60°C), Fuel Consumption: 4-5kg/vehicle

Filter system

Dual-filtering structure

Primary filter : Can Capture Granules Larger than 10μm

Ceiling filter : 600g high efficiency filter, can Capture Granules Bigger than 4μm

Floor filter: fiberglass filter, exhaust activated carbon filter, Filtering rate> 95%

Lighting system

Ceiling lights

8Units×4Pcs=32Pcs×36W900LUX , with anti-explosion design .

Side lights

6Units×4Pcs=24Pcs×30W900LUX , with anti-explosion design .

Control system

Spraying, heat spraying, time setting, lighting switch, failure indicator, thermostat, power supply switch, emergency stop. All motors are full voltage start.

Environmental System

Multi-Layer Fiberglasses Filter, active-carbon, and ensure a qualified exhaust according to the relevant state standards