| Use: | Power Tool |
|---|
Quick Details
Specifications
Battery charger specifications:
| NO. | ITEM | UNIT | SPECIFICATION | REMARK | |||||||
| INPUT | |||||||||||
| 01 | Rating input voltage | V ac |
100~240V ac 50/60Hz |
||||||||
| 02 | Input voltag range | V ac | 90~264V ac | ||||||||
| 03 | Rating input current | A | 0.3Arms |
INPUT:220V OUTPUT:Full load |
|||||||
| 04 | Max. input power | W | 5~12 | ||||||||
| OUTPUT | |||||||||||
| No. | ITEM | UNIT | Charger model | ||||||||
|
3PL0504E |
3PL0508E |
3PL1004E |
3PL1008E |
3PL1012E |
3PL1016E |
||||||
| 05 |
Rating output voltage |
V dc | 4.2 | 8.4 | 4.2 | 8.4 | 12.6 | 16.8 | |||
| 06 | Output voltage range | V dc |
3 ~ 4.25 |
6 ~ 8.5 |
3 ~ 4.3 |
6 ~ 8.6 |
9 ~ 12.75 |
12~ 17 |
|||
| 07 | Constant charge current | A |
0.8 ± 0.1 |
0.6 ± 0.1 |
1.7 ±0.2 |
1.2 ±0.2 |
0.9 ± 0.1 |
0.7 ± 0.1 |
|||
| 08 |
Suit with Battery type |
V/Ah |
3.7V |
7.4V |
3.7V |
7.4V 1.2~9Ah |
11.1V |
14.8V |
|||
| 09 | Charge finish condition | - |
U>4.2V |
U>8.4V |
>4.2V |
>8.4V &I<0.1A |
>12.6V &I<0.1A |
>14.8V &I<0.1A |
|||
| 10 | Max. output power | 5 | 5 | 12 | 12 | 12 | 12 | ||||
| 11 | Output short circuit protection | - | YES | YES | YES | YES | YES | YES | |||
| 12 |
Output Reverse polarity protection |
- | NO | NO | YES | YES | YES | YES | |||
| 13 | LED indicator | - | Red: Charging Green: Finish/idle | ||||||||
| 14 | Efficiency | % |
>70% |
At Max. load | |||||||
| ENVIRONMENT | |||||||||||
|
15 |
Operate temperature |
°C |
-10 ~ +40 |
Full load & natural convection |
|||||||
| 16 | Operate humidity | % RH |
< +90 |
Relative humidity, non-condensing |
|||||||
| 17 | Storge temperature |
°C |
-40 ~ +70 | ||||||||
| 18 | Storge humidity | % RH | 0 ~ +95 |
Relative humidity, non-condensing |
|||||||
| 19 | Cooling | - | Natural convection | ||||||||
| 20 | Temperature factor | % | - | ||||||||
| 21 | Vibration resistance | - |
5MM/50HZ/600S |
Non-operating condition |
|||||||
| 22 | Impact resistance | - |
1 meter drop test >= 3 times |
Non-operating condition |
|||||||
| MECHANICAL | |||||||||||
| 23 | Size | mm |
80*52*43 |
Casing only | |||||||
| 24 | Connect cable | - | Defined when order | ||||||||
| SAFETY | |||||||||||
| 25 | Max. temperature rise |
°C |
< 40 on casing |
At any line and Max. load | |||||||
| 26 | Safety standards | - |
GB4943 UL1950 EN60950 |
||||||||
| 27 | EMC stand | - | EN55022 B | ||||||||
| 28 | MTBF | Hours | 30000 | ||||||||
| 29 | Limited power source | VA | 50 | ||||||||
| 30 | ESD | kV | 8.0 | ||||||||
| 31 | Hi-Pot insulation | V |
i/p to o/p: 3000 (1 min.) |
For final unit, cut-off current =10mA |
|||||||