Usage: | LCR Meter |
---|---|
Power: | Electronic |
Model Number: | 2819 |
Brand Name: | CX |
Place of Origin: | China (Mainland) |
Items Name: | LCR Meter |
Warranty: | 1 year |
Basic accuracy: | 0.1% |
Average time: | 1-255 |
Quick Details
Specifications
Introduction
TH2819A digital LCR Meter is an updated product of TH2819 LCR meter with the features of TH2819, including easy operation, accurate and stable reading. It has smaller size than TH2819, nice appearance, and low cost.
With test frequency from 20Hz to 200kHz, frequency resolution of 10mHz, wide test signal level range from 5mV to 2V, measurement speed up to 32ms/time, TH2819A can be used to inspect electronic components, not only for measurement parameters TH2819 has, but DCR measurement. The meter has 1.5V/2V internal bias voltage, optional ±10V (±100mA) and 1A internal DC bias source and external inductance bias sources to inspect inductive components.
With high speed, wide test range, and 6-digit resolution, TH2819A can be used in quality control on production line, incoming inspection and lab measurement.
Measurement function |
||
Measurement parameters |
|Z|, |Y|, C, L, X, B, R, G, D, Q, θ , DCR |
|
Basic accuracy |
0.1% |
|
Equivalents circuit |
Serial, Parallel |
|
Math function |
Absolute value deviation, percentage deviation |
|
Range mode |
Auto, Hold, Manual |
|
Trigger mode |
Internal, Manual, External |
|
Measurement time (≥1kHz) |
Fast: 32ms, Medium: 90ms, Slow: 650ms |
|
Average time |
1—255 |
|
Delay time |
0—60s, with the step of 1ms |
|
Correction |
Open, Short, Load |
|
Measurement terminal |
5-terminal |
|
Display mode |
Direct, Δ, Δ%, V/I (voltage/current monitor) |
|
Display |
320×240 dot matrix graphic LCD display with 6-digit resolution |
|
Test signal |
||
Test signal frequency |
20 Hz-200 kHz |
|
Frequency min. Resolution |
10mHz |
|
Output impedance |
30 Ω, 100 Ω |
|
Test signal level |
Normal: 5 mV-2 V Accuracy: 10% Constant level: 10 mV-1 V Accuracy: 5% |
|
Level min. Resolution |
1mV |
|
DC bias source |
Internal |
0V, 1.5V, 2V, accuracy: 1% |
Optional |
TH1902A 0-10V DC bias voltage, 0-100mA DC bias current |
|
TH1902B 0-1A DC bias current |
||
Measurement display range |
||
|Z|, R, X |
0.00001 Ω — 99.9999 MΩ |
|
DCR |
0.001 Ω — 99.9999 MΩ |
|
|Y|, G, B |
0.00001μS — 99.9999 S |
|
C |
0.00001 pF — 9.9999 F |
|
L |
0.00001 μH — 9999.99 H |
|
D |
0.00001 — 9.9999 |
|
Q |
0.00001 — 9999.9 |
|
θ (DEG) |
-179.999o — 179.999 o |
|
θ (RAD) |
-3.14159 — 3.14159 |
|
Δ% |
-999.999% — 999.999% |
|
Others |
||
Comparator |
10-bin sorting, bin counter |
|
Storage |
20 sets of LCRZ measurement settings saved |
|
Interface |
RS232C, HANDLER, GPIB (optional), USB HOST (optional) |