| Output: | Analog Sensor |
|---|---|
| Theory: | Resistance Sensor |
| Usage: | Vibration Sensor |
| Brand Name: | EGL |
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
Single Seismic Geophone with KCK Screw Fit Male Connector, with Vertical Direction and Horizontal Direction optional. Follwing Geophone Types are available:
Single Seismic Geophone 1Hz
Single Seismic Geophone 2Hz
Single Seismic Geophone 2.5Hz
Single Seismic Geophone 3Hz
Single Seismic Geophone 4Hz
Single Seismic Geophone 4.5Hz
Single Seismic Geophone 8Hz
Single Seismic Geophone 10Hz
Single Seismic Geophone 14Hz
Single Seismic Geophone 15Hz
Single Seismic Geophone 28Hz
Single Seismic Geophone 30Hz
Single Seismic Geophone 38Hz
Single Seismic Geophone 40Hz
Single Seismic Geophone 60Hz
Single Seismic Geophone 80Hz
Single Seismic Geophone 100Hz
All the geophones are equipped in Land Case with Steel Soil Spike and 1Meter Leader Cable and Terminated with KCK Male Screw Fit Connector.
Data Sheet for 40Hz Geophone:
Natural Frequency (
Hz ):40 ± 5.0%
Coil Resistance (Ω):540 ± 5.0%
Open Circuit Damping:0.620 ± 5.0%
Damping With Shunt
Resistor:0.648 ± 5.0%
Open Circuit
Intrinsic Voltage Sensitivity ( v/m/s ):32.5 v/m/s ± 5.0%
Sensitivity With
Shunt Resistor:30.3 v/m/s ± 5.0%
Damping
Calibration-Shunt Resistance(Ω):7500
Harmonic
Distortion(%):<0.20%
Typical spurious
frequency ( Hz ):≥300Hz
Moving Mass ( g ):9.3g
Typical Case To Coil
Motion p-p ( mm ):1.8mm
Operating Temperature Range ( ℃ ):-40℃ TO +100℃