Product Main

Specifications

http:// /> Brief Introduction

XMT-288F(C) Series Digital Display Thermometers are our specially-designed complete sets to electrical transformers. With connected with a BWY(WTYK)-802A or -803A Thermoregulator, the XMT-288F(C) can take remote measurement and control of the oil temperature in an electrical transformer. The series Thermometers include two models of XMT-288F and XMT-288FC, of which the latter can output the standard signals including o~5VDC.1~5VDC or 4~20mADC to link with a computer.

2. Main Technical Parameters


2-1 input signal: Pt100

2-2 measuring range: 0~100℃ 0~120℃ 0~150℃ -20~80℃

2-3 Accuracy: grade 1.0

2-4 display modes: 0.8〞×7nixie tube

2-5 resolution ratio: 0.1℃

2-6 setting range: adjustable within the whole span

2-7 lead-in wire: three-wire system

2-8 contact output: both upper and low limit alarms with a set of normally opened and closed contacts each

2-9 contact capacity: 220VAC.3A

2-10 standard signal output (confined to XMT-288FC):0~5VDC.1~5VDC or 4~20mADC

?which correspond to meter`s measuring range respectively

?and of which the signal output of 4~20mADC is allowed a load resistance of 250~350Ω

2-11 power supply:220VAC﹑50HZ

2-12 power rating: 6W

2-13 working environment:Ambient temperature: 0~50℃ Ambient humidity: <85%

2-14 outline dimension: 160mm wide and 80mm high with 125mm deep dimension of open pore: 152mm wide and 76mm high

1. Brief Introduction

XMT-288F(C) Series Digital Display Thermometers are our specially designed complete sets to electrical transformers. With connected with a BWY(WTYK)-802A or -803A Thermoregulator, the XMT-288F(C) can take remote measurement and control of the oil temperature in an electrical transformer. The series Thermometers include two models of XMT-288F and XMT-288FC, of which the latter can output the standard signals including o~5VDC.1~5VDC or 4~20mADC,and XMT-288FC-Ⅱowns port RS485 or RS232 to link with a computer directly.

2. Main Technical Parameters

2-1 Input signal: Pt100

2-2 Measuring range: 0~100℃ 0~120℃ 0~150℃ -20~80℃

2-3 Accuracy: grade 1.0

2-4 Display modes: 0.8〞×7nixie tube

2-5 Resolution ratio: 0.1℃

2-6 Setting range: adjustable within the whole span

2-7 Lead-in wire: three-wire system

2-8 Contact output: both upper and low limit alarms with a set of normally opened or closed contacts each

2-9 Contact capacity: 220VAC.3A

2-10 Standard signal output (confined to XMT-288FC):DC:0~5VDC.1~5VDC or 4~20mADC Communication port:RS485,RS232(XMT-288FC-Ⅱ) Which correspond to meter`s measuring range respectively and of which the signal output of 4~20mADC is allowed a load resistance of 250~350Ω.

2-11 Power supply:220VAC﹑50HZ

2-12 Power rating: 6W

2-13 Working environment:Ambient temperature: 0~50℃ Ambient humidity: <85%RH

2-14 Outline dimension: 160mm wide and 80mm high with 125mm deep Dimension of open pore: 152mm wide and 76mm high