Main Features
True double-conversion
DSP technology guarantees high performance
Output power factor 0.8
Wide input voltage range (110-300 VAC)
Active power factor correction in all phases
Built-in phase auto adapt function simplifies wire installation
50Hz/60Hz frequency converter mode
Eco mode operation for energy saving (ECO)
Emergency power off function (EPO)
Generator compatible
SNMP+USB+RS-232 multiple communications
3-stage extendable charging design for optimized battery performance
Adjustable battery numbers
Optional N+X parallel redundancy
* Product specifications are subject to change without further notice
True double-conversion
DSP technology guarantees high performance
Output power factor 0.8
Wide input voltage range (110-300 VAC)
Active power factor correction in all phases
Built-in phase auto adapt function simplifies wire installation
50Hz/60Hz frequency converter mode
Eco mode operation for energy saving (ECO)
Emergency power off function (EPO)
Generator compatible
SNMP+USB+RS-232 multiple communications
3-stage extendable charging design for optimized battery performance
Adjustable battery numbers
Optional N+X parallel redundancy
Model |
Galleon 3/1-10KR (L) | Galleon 3/1-15KR (L) | Galleon 3/1-20KR (L) | |
PHASE | 3-phase in / 1-phase out | |||
CAPACITY | 10000 VA/8000 W | 15000 VA/12000 W | 20000 VA / 16000 W | |
INPUT | ||||
Nominal Voltage | 3 x 400 VAC (3Ph+N) | |||
Voltage Range | 305-478 VAC (3-phase) at 100% load ; 190-520 VAC (3-phase) at 50% load | |||
Frequency Range | 46~54 Hz or 56~64Hz | |||
Power Factor | more than 0.99 @ 100% Load | |||
THDi | < 6% @ 100% Load | |||
OUTPUT | ||||
Output Voltage | 208/220/230/240VAC | |||
AC Voltage Regulation (Batt. Mode) | ± 1% | |||
Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz | |||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |||
Current Crest Ratio | 3:1 | |||
Harmonic Distortion | less 2 % THD (Linear Load) ; less5 % THD (Non-linear Load) | |||
Transfer Time | AC Mode to Batt. Mode | Zero | ||
Inverter to Bypass | Zero | |||
Waveform (Batt. Mode) | Pure Sinewave | |||
EFFICIENCY | ||||
AC Mode | 89% | |||
Battery Mode | 86% | 88% | 87% | |
BATTERY | ||||
Standard Model | Battery Type | 12 V / 7Ah | ||
Numbers | 20 (18 - 20 adjustable) | 20 pcs x 2 strings (18 - 20 adjustable) | ||
Typical Recharge Time | 9 hours recover to 90% capacity | |||
Charging Current (Max.) | 1A | 2A | ||
Charging Voltage | 273 VDC ± 1% (based on battery numbers at 20 pcs) | |||
Long-run Model | Battery Type | Depending on the capacity of external batteries | ||
Numbers | ||||
Charging Current (Max.) | 4A | |||
Charging Voltage | 273 VDC ± 1% (based on battery numbers at 20 pcs) | |||
INDICATORS | ||||
LCD Display | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | |||
ALARM | ||||
Battery Mode | Sounding every 4 seconds | |||
Low Battery | Sounding every second | |||
Overload | Sounding twice every second | |||
Fault | Continously sounding | |||
PHYSICAL | ||||
Standard Model | Dimension, DxWxH (mm) |
UPS unit:500x248x563(3U) Battery pack: 580 x 438 x 133(3U) |
UPS unit:500x248x563(6U) Battery pack: 580 x 438 x 133(3U) x 2PCS |
|
Net Weight (kgs) |
UPS unit: 27 Battery pack: 63 |
UPS unit: 45 Battery pack: 63 x 2PCS |
||
Long-run Model | Dimension, DxWxH (mm) | 500x248x563(3U) | 500x248x563(6U) | |
Net Weight (kgs) | 27 | 35 | ||
ENVIRONMENT | ||||
Operation Humidity | 0-95 % RH @ 0- 40°C (Non-condensing) | |||
Noise Level | Less than 60dB @ 1 Meter | Less than 65dB @ 1 Meter | ||
MANAGEMENT | ||||
Smart RS-232/USB | Supports Windows? 2000/2003/XP/Vista/2008, Windows? 7/8, Linux, Unix, and MAC | |||
Optional SNMP | Power management from SNMP manager and web browser |
* L means long-run model |
* Product specifications are subject to change without further notice