| Output Current: | 5A |
|---|---|
| Output Frequency: | 50HZ/60HZ |
| Type: | DC/AC Inverters |
| Output Voltage: | 220VAC |
| Input Voltage: | -- |
| Size: | 423*260*453 |
| Output Type: | Single |
| Output Power: | 401 - 500W |
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
Ⅰ, Characteristics
● MCU intelligent control excellent performance
● Pure sine wave AC output, strong capacity of different loads
● 5VDC-USB output &12VDC terminal output, Convenient and
practical
● PV array and battery system input
● Protection for over charge, over discharge, can extend the life
span of the Battery
● Digital meter & LED display, easy to know Equipment operating
status
● Overload protection, short circuit protection and others automatic
protection and alarm
3.3.2. Solar charging / discharging LED Status Description
|
LED Display |
Description |
||
|
Solar |
Green |
on |
Charge controller during Charging….. |
|
flash |
Charge controllers prepare Charging…. |
||
|
off |
Charge controller on standby….. |
||
|
Battery |
Green/Red |
Red flash quickly |
Battery over voltage;>16V; (×2/24VDC) |
|
Green flash |
Battery over voltage protection;>13.8V; (×2/24VDC) |
||
|
Green on |
Battery voltage normal |
||
|
Orange(Red & Green on) |
Battery low voltage;<11.6V; (×2/24VDC) |
||
|
Red on |
Battery low voltage protection;<11.1V; (×2/24VDC) |
||
|
DC Output |
Yellow |
Flash quickly |
DC current Overload or short circuit |
|
on |
DC output voltage normal |
||
|
Flash |
DC current overload |
||
|
off |
DC output shut off |
||
3.3.3. AC output LED Status Description / buzzer prompt state instructions
" INV" Orange light: Lights indicate AC output normal;
" FAULT" Red light: Lights or flashes that AC output overload / short / trouble / low battery power
|
" Inv" indicate |
" Fault" indicate |
Status |
|
|
On |
off |
AC output normal work |
|
|
Battery low voltage alarm |
|||
|
On |
flash |
1'sec buzz one time |
AC output overload |
|
On |
Buzz long time |
C output overload badly |
|
|
On |
3'sec buzz one time |
Battery low voltage/over voltage protection |
|
|
Buzz long time |
AC output short circuit or Equipment failure |