| Output Frequency: | 50Hz/60Hz |
|---|---|
| Type: | DC/AC Inverters |
| Output Voltage: | 220/230/240VAC |
| Input Voltage: | 12/24/48v |
| Output Type: | Single |
| Output Power: | >1000KW |
| Model Number: | Power Star Series PS8Kw-12Kw |
| Brand Name: | UPSEN |
| Place of Origin: | China (Mainland) |
| Frequency: | 50Hz/60Hz |
| Waveform: | Pure Sine Wave |
| OEM: | Yes |
| Feature: | Pure Sine Wave Inverter |
| H.S.: | 8504403090 |
Quick Details
Specifications
power inverter dc to ac power inverter with High overload ability
Pure Sine Wave Inverter Charger Power Star Series PS8Kw-12Kw (1ph in/1ph out)
Key Features:
On inverter
1:High overload ability
2:Low battery voltage trip selectable, extracting max power from various batteries with different protections
3:Low quiescent current, selectable sensing cycle to reduce power consumption
On battery charge
1:3-step intelligent battery charging
2:Powerful charge rate up to 100Amp ,selectable charging current
3:8 preset battery type selector plus de-sulphation for totally flat batteries
4:PFC(Power Factor Correction) for charger, less power consumption than conventional units
On Transfer
1:30A/40A through current ability
2:Output voltage regulation optional
3:8 ms typical transfer time, guarantees power continuity
4:Input AC voltage range selectable, for different kinds of loads
5:Delay before transfer, extra protections for loads under generator mode
On remote control & other features
1:Ability to switch the unit on/off
2:LCD status display available
3:RS232 communication port optional
4:Ability to select/deselect power saver mode
5:17 alarms/warnings, informative for easier operation and trouble-shooting
6:Protection:Low voltage/Over voltage/Over temperature/Overload/Short circuit
Technical Specification
Pure Sine Wave Inverter Charger Power Star Series PS8Kw-12Kw (1ph in/1ph out)
Key Features:
On inverter
1:High overload ability
2:Low battery voltage trip selectable, extracting max power from various batteries with different protections
3:Low quiescent current, selectable sensing cycle to reduce power consumption
On battery charge
1:3-step intelligent battery charging
2:Powerful charge rate up to 100Amp ,selectable charging current
3:8 preset battery type selector plus de-sulphation for totally flat batteries
4:PFC(Power Factor Correction) for charger, less power consumption than conventional units
On Transfer
1:30A/40A through current ability
2:Output voltage regulation optional
3:8 ms typical transfer time, guarantees power continuity
4:Input AC voltage range selectable, for different kinds of loads
5:Delay before transfer, extra protections for loads under generator mode
On remote control & other features
1:Ability to switch the unit on/off
2:LCD status display available
3:RS232 communication port optional
4:Ability to select/deselect power saver mode
5:17 alarms/warnings, informative for easier operation and trouble-shooting
6:Protection:Low voltage/Over voltage/Over temperature/Overload/Short circuit
Technical Specification
| Power Star Series | ||||||
| Model No. | PS8K | PS10K | PS12K | |||
| Nominal Power | 8KW | 10KW | 12KW | |||
| AC Input | ||||||
| Phase & Waveform | Single Phase & Pure Sine Wave | |||||
| Voltage | 220/230/240VAC | |||||
| Acceptable Voltage | 154-273VAC | |||||
| Line Low Transfer | 154V | |||||
| Line Low Return | 164V | |||||
| Line high Transfer | 273V | |||||
| Line high Return | 263V | |||||
| Frequency | 50Hz or 60Hz (Auto sensing) | |||||
| Line Low Transfer | 40Hz | |||||
| Line high Transfer | 80Hz | |||||
| AC Output | ||||||
| Phase & Waveform | Single Phase & Pure Sine Wave(bypass mode sync to input) | |||||
| Voltage | 220/230/240VAC (Same as Input on bypass mode) | |||||
| Voltage Regulation | ±10%rms(bypass mode sync to input) | |||||
| Frequency | 50Hz or 60Hz (Auto sensing) | |||||
| Crest Power | 3 times of rating power | |||||
| Short Circuit Protection | Yes,shutdown | |||||
| Power Factor | 0.9-1.0 | |||||
| DC Input | ||||||
| Battery Voltage | 48V | |||||
| Minimum Start Voltage | 40V | |||||
| Low Battery Alarm | 44V | |||||
| Low Battery Transfer | 40V | |||||
| High Voltage Alarm | 64V | |||||
| Max Charging Current | 75A | 85A | 100A | |||
| Over Charge Voltage | 62.8V | |||||
| Transfer Efficiency | ||||||
| Line Mode | >95% | |||||
| Battery Mode | >88% | |||||
| power saver | Available when the load is less than 75 Watts | |||||
| Indicators | ||||||
| 4-LED Display | Charge, Line, Inverter, Fault | |||||
| LCD Display | Input/Output Voltage, Frequency, Battery Voltage, Load, Tempreture, Charge Current,Fault | |||||
| Switch selector | Saving Mode is on/off when push the switch forwards/backwards, keeping it horisontal is turning the inverter off. | |||||
| Audible Alarm | Sounding when the heatsink's tem is over 105oC and shutdown after 30 seconds. | |||||
| Protections | low battery,over charging,over temp,over load | |||||
| Communications | RS232/RJ11(Optional) | |||||
| Enviromental | ||||||
| Operating Environment | 0-40oC,0-90%RH(non-condensing) | |||||
| Audible Noise | <60dB | |||||
| Physical | ||||||
| Net Weight(KG) | 56 | 64 | 68 | |||
| Dimension L*W*H(mm) | 549*450*201mm | 584*450*201mm | ||||
|
*Specification is subject to change without prior notice. |
||||||