Product Main

Quick Details

Model Number: Teren-EFM-DC
Brand Name: Teren
Place of Origin: China (Mainland)
Accuracy: 0.5%

Specifications

Technical data:

 

Nominal meter size

10-2200mm(3/8 to 86 inch)

Accuracy

±0.5%

Minimum Conductivity

>5μs/cm

Fluid temperature

-25 to 60°C(-13 to 140°F)

-25 to 180°C(-13 to 356°F)(opt.)

Liner

CR,FEP,PTFE,PFA

Ambient temperature

-10 to 60°C(14 to 140°F)

Electrode material

SS316L(Standard),Hastelloy,Tantalun,Titanium,Tungsten Carbide(Upon requirements)

Current Output

0 to 10mA or 4 to 20mA

Frequency Output

0 to 5000Hz with photoelectric isolation

Pulse Output

Adjustable from 0.001 to 1000Ltr/Pulse

Alarm Output(opt.)

Upper Alarm-ALMH,Lower Alarm-ALML with photoelectric isolation

Upper Alarm-ALMH,Lower Alarm-ALML with photoelectric isolation

Communications(opt.)

RS-232 without galvanic isolation

RS-485 with galvanic isolation

MODBUS

Power supply

85 to 250VAC(45 to 63Hz)

20-36VDC

Power

S<10QW/AC

S<7.5W/DC

 

Application Field:

    Electromagnetic flowmeter products can be widely used in chemical, steel, coal, mining, oil exploration, petrochemical, paper, environmental protection, sugar, pharmaceutical, food, irrigation, drainage and port dredging and other fields, can accurately measure a variety of acid, alkali, salt solution, raw water, cooling water, sewage, coal slurry, slurry, mud, water, mud, pulp, syrup, coal water slurry, corn syrup, fiber pulp, grain syrup, lime, hydrogen peroxide, beer, wort black liquor, green liquor and a variety of beverages and other liquid and solid-liquid two-phase fluid conductive body volume flow.