Product Main

Quick Details

Model Number: 025
Brand Name: HuaFan QinLu
Place of Origin: China (Mainland)

Specifications

website:
http://>

Cabinet can be broadly divided into the front panel, rear panel, power supply, in the attachment, and a cooling fan, etc.

1.The front panel
Front panel include: lamp panel, instrument panel, blind flange.

Lamp panel

Height : 3u 

Including alarm lamp, lamp panel (power switch), whistle at the same time produce sound and light alarm.There is no alarm, green indicator is on.

Each instrument panel can be installed on the nine independent instrument.

Instrument

Each meter width of 48 mm, vertical installation, digital tube adopts four 0.39 -inch integrated highlight typetogether highlight type, digital tube size: 40 x 14 mm.

Set on the instrument panel 2 Φ 3 mm highlight LED, respectively, indicating "first alarm", "secondalarm".

Buttons  uses film to panel sticker design processing together.Button and circuit board use soft wire connectionbefore.

2, The rear panel
Rear panel is mainly installed "wiring board", each corresponding to a wiring board instrument panel.

Wiring board using 2 mm thick PCB to realize.
User terminal surface using the beauty of the spacing of 7.62 mm gauge terminal SH902A - 7.62, under the 4 pin, placed back-to-back.

4-20 ma signal above a row of connection, a line connecting relay output below.

Use of spacing of 3.96 mm single 12 pin on the back of call waiting type terminal (socket), instrument with the plug can be directly in the socket.

Instrument of power supply (+ 24 v, GND) and alarm , three lines on the circuit board directly connected.

Nine Alarm signal after "or" logic as a signal.Power sockets and alarm signals respectively use two core socket placed on one end of the wiring board.

3, Power supply
Power supply with switching power supply, specifications: 24 v / 200 w.
Each switch power supply connects three sets of instrument panel (3 x 9).

Inside the cabinet with a PDU (1 u) or a power outlet.

All of the switch power supply PDU or socket.
Grounding: cabinet wiring, strict enforcement of grounding specification.

Basic parameters:
Working voltage: AC220V 50 hz
Output voltage: DC 24 v
Channel number: 90-120 road (cabinet height 1.8 m)
Display mode: up to 120 road transmitter can display testing data at the same time

Signal input: 4-20 ma
Control output: can provide corresponding channel switch output,
10 a maximum load capacity is 250 v AC
Sampling accuracy: 12 AD
Measuring range: 0-9999 (numerical) can be set up
More than 120 db alarm way: the secondary alarm
Connection mode: can connect two wire,

 three wire system 4-20 ma current signal of the transmitter
Temperature range: - 10 ℃ to 50 ℃
Humidity: 15% ~ 70% RH (No condensation)