Model Number: | wickon x6 thermal profile |
---|---|
Brand Name: | wickon x6 thermal profilling |
Place of Origin: | Germany |
Usage: | Industrial, reflow oven temeperature profile test |
Theory: | Temperature Recorder |
Temperature Range: | -150 ~1370 degree |
Sampling frequency: | 0.05s~60Min |
Run Voltage: | 3.7V~4.2VDC |
Quick Details
Specifications
KIC,DATAPAQ WICKON DATA compare | |||||
hardware | Item | USA KIC | UK DATAPAQ | Germany Wickon | Comparison Description |
Channel | 6, 7, 9, 12 | 6, 10, 12 | 6, 7, 10, 12, 15, 24, 32 | Wickon more selectively | |
Measurement accuracy(℃) | +/- 0.1℃ | +/- 0.5℃ | +/- 0.5℃ | nearly | |
Analytical precision | +/- 0.5℃ | +/- 0.1℃ | +/- 0.01℃ | Wickon resolve highest precision | |
Test range | -150℃~1050℃ | -200℃~1370℃ | -200℃~1370℃ | KIC narrow temperature range | |
Internal operating temperature | 0℃~85℃ | 0℃~85℃ | -40℃~105℃ | Wickon good temperature resistance | |
sampling interval | 0.1~10S | 0.05~60S | 0.05~86400S | KIC slow response | |
Storage capacity | 224,640.00 | 216,000.00 | 4,000,000.00 | Wickon with big storage capacity | |
Length frequency of use | one times | one times | 24 times | High efficiency for Wickon | |
Start mode | Temperature trigger | Button to start | Start / Stop button, time or temperature trigger | Wickon with more startup mode | |
USB communication port Compare | USB communication can not be charged | USB communication can not be charged | USB can charging and communicate | Wickon realize USB communication with the USB charging function | |
Standard K-type thermocouple | OMEGA standard reaction speed 0.2 seconds | Standard LABFACILITY reaction speed 0.1 seconds | Standard LABFACILITY reaction speed 0.1 seconds | KIC with thermocouple slow response | |
Logger size :mm | 206*75*20(9channel) | 221*60*20(10channel ) | 176*45*20(10 channel ) | Wickon size is smallest | |
Insulated box | Stainless steel anti-hot cotton stick, snap closure mode | Stainless steel nano-materials posted Germany, closed way snap spring | Stainless steel nano-materials posted Germany, closed way snap spring | KIC anti-hot, but poor insulation, inconvenient to switch | |
battery | Disposable AAA batteries (3), can be measured 25 to 50 times | Rechargeable nickel-metal hydride batteries can be measured 30 to 50 times | Lithium polymer battery, comes with USB charging function, sustainable use, long standby up to 365 days. | KIC battery costs are high, Wickon without deliberately charging. | |
software | SMT / DIP Application | KIC can be dual-use, measured wave soldering defects, sometimes undetectable tin furnace temperature. | DATAPAQ can be dual-use, software defects, imbalance testing. | WICKON can be dual-use, powerful wave test, automatic partitioning, there is balance testing. | Wickon dual advantage |
Import and export data analysis process | KIC no such function, not export the data analysis process | DATAPAQ have this feature, but the exported data will be negative error | WICKON this function without any given phenomenon, and can be exported automatically analyzes, Automatic Partitioning | Limited KIC software features | |
PWI automatic analysis function | There PWI automatic determination | DATAPAQ no this function | with PWI automatic determination | DATAPAQ no this function | |
Process optimization | yes | no | yes | DATAPAQ no this function | |
Craft editing interface | A window can only analyze a process | A window can only analyze a process | A window to complete all process | Wickon edit faster and more convenient | |
Merge function curve | yes | no | no | KIC has a merge function curve | |
A shortcut | only one | only one | three ways | Wickon operation more user-friendly | |
Image insertion | no | yes | yes | KIC No picture insertion | |
Continuous recording multiple sets of data | no | no | 24 sets | Wickon continuous testing production lines |
1.Comprehensive Monitoring for Temperature curve
For high temperature industries(sintering furnace, annealing furnace, IR oven, spray, reflow and wave soldering, etc.) Statistical analysis for process, Control of product quality exactly, improve work efficiency, reduce scrap rates, to reduce product costs .
Our SURVEYYOR can be adjusted enhancements to control the furnace temperature stability, than reduce the amount of our test board ,not only save company's cost , but also improve work efficiency.
Temperature chart recorder also can enter unleaded process quickly.Whenever the introduction of a new product or paste than they need to be optimized for the reflow oven set - which is a time-consuming process.Equipment ROS of Wickon by calculating the best ovens, product and recycled to set the target temperature curve settings.Only a few seconds instead of several hours from others.
A: High efficiency, continuous data stored 24 times, downloaded to a computer packet analysis and processing;
B: modular analysis mode, simple, fast analysis system based on PC (Windows)
And PDA (Pocket) for data analysis;
C:Low power, battery, up to 168 hours of continuous use of the above,
365 ultra-long standby, without deliberately charging;
D:Communication mode uses USB transfer, for a variety of work environments and application areas
E: rigorous manufacturing process and accurate calibration services, all correction are used FLUKE-724 school
Positive, with China's largest institutional partners CTI calibration.
F: ensure that each machine is accurate, reliable, small size, large storage capacity (5,000,000 Data
Point), the use of FLASH memory chips, will not lose any accident data;
G: High stability
H:fairly long life, there is now a lot more than a decade of use WICKON life company
I:multichannel recorder obtain maximum element temperature curve.
J:insulated box can cope with the most severe heat deputy shot process (using black box technology)
K:Powerful Insight software is now with the process of measuring volatility,
L: temperature profile and the ability to predict SPC calculations.
2. the principle FOR Profiler :
(1) Data Logger
Wickon Q series data loggers are used in the recycling process today's most accurate recorder. It has a precision of ± 0.5, 0.1 degree resolution and 5,000,000 readings more storage capacity, it can provide detailed information on the depth of the analysis process. X series with a direct USB communication characteristics, so that information can be transmitted as quickly as possible from the data recorder to a PC.
(2) Hot Box
Wickon used in lead-free solder protection under common temperature loggers. It uses the "black box" flight recorder on an aircraft instrument same insulation technology, is enclosed in a rugged stainless steel housing.
(3) the basic principles of thermocouple
A conductor or semiconductor and B of two different materials welded together, form a closed loop. When there is a temperature difference between two contacts conductors A and B, they generate thermal electromotive force between the two, a phenomenon known as the thermoelectric effect. Thermocouple is to use this effect to work.
(4) Insight Software Features
Guide
All the usual features are based wizard, such as tolerance curve, technical documents. Even with fairly complex analysis, the wizard guides you step by step through the process temperature curve test, make sure to complete all phases of the test and save training time.
Alert
The new features are available to alert you when an error prompt. Numerical analysis can give any one domain set alarms. If a value exceeds the limit, an alert appears on the screen so you can quickly identify the problem.
SPC historical data to calculate
Insight software enables users to quickly and easily with a temperature curve historical data for SPC calculations. So - to the stability and capacity of the welding process can be tested.