Model Number: | wickon A6L thermal profile |
---|---|
Brand Name: | wickon A6L thermal profilling |
Place of Origin: | Germany |
Memory: | 5,000,000points |
Test Channel: | 6 channels |
Sampling frequency: | 0.05s~60Min |
Resolution: | 0.1 degree |
Precision: | +-0.5 degree scale |
Max. inner runtemperature: | 105degree |
Temperature range: | -150 ~1370 degree |
Run Voltage: | 3.7V~4.2VDC |
Thermocouple Types: | K wire(TT OR GG0.010inch/0.254mm) |
Start-up mode: | Switch button,starts the temperature |
Quick Details
Specifications
Specifications
1.Quick,convenient,accurate
2.High cost performance, simple operation
3.Convenient and easy to use software
KIC,DATAPAQ WICKON DATA compare
hardware system
Item
USA KIC
UK DATAPAQ
Germany Wickon
Comparison Description
Channel
6, 7, 9, 12
6, 10, 12
6, 7, 10, 12, 15, 24, 32
Wickon more selectively
Measurement accuracy(℃)
+/- 0.1℃
+/- 0.5℃
+/- 0.5℃
nearly
Analytical precision
+/- 0.5℃
+/- 0.1℃
+/- 0.01℃
Wickon resolve highest precision
Test range
-150℃~1050℃
-200℃~1370℃
-200℃~1370℃
KIC narrow temperature range
Internal operating temperature
0℃~85℃
0℃~85℃
-40℃~105℃
Wickon good temperature resistance
sampling interval
0.1~10S
0.05~60S
0.05~86400S
KIC slow response
Storage capacity
224,640.00
216,000.00
4,000,000.00
Wickon with big storage capacity
Length frequency of use
one times
one times
24 times
High efficiency for Wickon
Start mode
Temperature trigger
Button to start
Start / Stop button, time or temperature trigger
Wickon with more startup mode
USB communication port Compare
USB communication can not be charged
USB communication can not be charged
USB can charging and communicate
Wickon realize USB communication with the USB charging function
Standard K-type thermocouple
OMEGA standard reaction speed 0.2 seconds
Standard LABFACILITY reaction speed 0.1 seconds
Standard LABFACILITY reaction speed 0.1 seconds
KIC with thermocouple slow response
Logger size :mm
206*75*20(9channel)
221*60*20(10channel )
176*45*20(10 channel )
Wickon size is smallest
Insulated box
Stainless steel anti-hot cotton stick, snap closure mode
Stainless steel nano-materials posted Germany, closed way snap spring
Stainless steel nano-materials posted Germany, closed way snap spring
KIC anti-hot, but poor insulation, inconvenient to switch
battery
Disposable AAA batteries (3), can be measured 25 to 50 times
Rechargeable nickel-metal hydride batteries can be measured 30 to 50 times
Lithium polymer battery, comes with USB charging function, sustainable use, long standby up to 365 days.
KIC battery costs are high, Wickon without deliberately charging.
software system
SMT / DIP Application
KIC can be dual-use, measured wave soldering defects, sometimes undetectable tin furnace temperature.
DATAPAQ can be dual-use, software defects, imbalance testing.
WICKON can be dual-use, powerful wave test, automatic partitioning, there is balance testing.
Wickon dual advantage
Import and export data analysis process
KIC no such function, not export the data analysis process
DATAPAQ have this feature, but the exported data will be negative error
WICKON this function without any given phenomenon, and can be exported automatically analyzes, Automatic Partitioning
Limited KIC software features
PWI automatic analysis function
There PWI automatic determination
DATAPAQ no this function
with PWI automatic determination
DATAPAQ no this function
Process optimization
yes
no
yes
DATAPAQ no this function
Craft editing interface
A window can only analyze a process
A window can only analyze a process
A window to complete all process
Wickon edit faster and more convenient
Merge function curve
yes
no
no
KIC has a merge function curve
A shortcut
only one
only one
three ways
Wickon operation more user-friendly
Image insertion
no
yes
yes
KIC No picture insertion
Continuous recording multiple sets of data
no
no
24 sets
Wickon continuous testing production lines
1.Comprehensive Monitoring for Temperature curve
For high temperature industries(sintering furnace, annealing furnace, IR oven, spray, reflow and wave soldering, etc.) Statistical analysis for process, Control of product quality exactly, improve work efficiency, reduce scrap rates, to reduce product costs .
Our SURVEYYOR can be adjusted enhancements to control the furnace temperature stability, than reduce the amount of our test board ,not only save company's cost , but also improve work efficiency.
Temperature chart recorder also can enter unleaded process quickly.Whenever the introduction of a new product or paste than they need to be optimized for the reflow oven set - which is a time-consuming process.Equipment ROS of Wickon by calculating the best ovens, product and recycled to set the target temperature curve settings.Only a few seconds instead of several hours from others.
A: High efficiency, continuous data stored 24 times, downloaded to a computer packet analysis and processing;
B: modular analysis mode, simple, fast analysis system based on PC (Windows)
And PDA (Pocket) for data analysis;
C:Low power, battery, up to 168 hours of continuous use of the above,
365 ultra-long standby, without deliberately charging;
D:Communication mode uses USB transfer, for a variety of work environments and application areas
E: rigorous manufacturing process and accurate calibration services, all correction are used FLUKE-724 school
Positive, with China's largest institutional partners CTI calibration.
F: ensure that each machine is accurate, reliable, small size, large storage capacity (5,000,000 Data
Point), the use of FLASH memory chips, will not lose any accident data;
G: High stability
H:fairly long life, there is now a lot more than a decade of use WICKON life company
I:multichannel recorder obtain maximum element temperature curve.
J:insulated box can cope with the most severe heat deputy shot process (using black box technology)
K:Powerful Insight software is now with the process of measuring volatility,
L: temperature profile and the ability to predict SPC calculations.
2. the principle FOR solder reflow profile WICKON A6L :
(1) Data Logger
Wickon Q series data loggers are used in the recycling process today's most accurate recorder. It has a precision of ± 0.5, 0.1 degree resolution and 5,000,000 readings more storage capacity, it can provide detailed information on the depth of the analysis process. X series with a direct USB communication characteristics, so that information can be transmitted as quickly as possible from the data recorder to a PC.
(2) Hot Box
Wickon used in lead-free solder protection under common temperature loggers. It uses the "black box" flight recorder on an aircraft instrument same insulation technology, is enclosed in a rugged stainless steel housing.
(3) the basic principles of thermocouple
A conductor or semiconductor and B of two different materials welded together, form a closed loop. When there is a temperature difference between two contacts conductors A and B, they generate thermal electromotive force between the two, a phenomenon known as the thermoelectric effect. Thermocouple is to use this effect to work.
(4) Insight Software Features
Guide
All the usual features are based wizard, such as tolerance curve, technical documents. Even with fairly complex analysis, the wizard guides you step by step through the process temperature curve test, make sure to complete all phases of the test and save training time.
Alert
The new features are available to alert you when an error prompt. Numerical analysis can give any one domain set alarms. If a value exceeds the limit, an alert appears on the screen so you can quickly identify the problem.
SPC historical data to calculate
Insight software enables users to quickly and easily with a temperature curve historical data for SPC calculations. So - to the stability and capacity of the welding process can be tested.