Product Main

Quick Details

Usage: Auto Testing Machine
Power: Electronic
Model Number: LEDLM-80PL
Brand Name: LISUN
Place of Origin: China (Mainland)

Specifications

LEDLM-80PL Life Testing Machine - acceleration led lumen maintenance test system  Introduction:

 

Item

Optical decay rate

L50(h)

L30(h)

85°C

8%

8312.950414

4277.62127

70°C

3%

22756.57306

11709.922

 

The temperature Tj (the contact surface temperature between LED and circuit board, or ambient temperature providing the heat-sink is complete, but the junction temperature will be 15°C higher than ambient temperature in 350mA) will greatly affect the test result. We can predict the LED life under varies temperature according to formula 2. Suppose the time t1 is the LED life under T1 temperature, time t2 is the LED life under T2 temperature, then we can calculate the time t3 under T3 temperature:

t3=t1*exp{(ln(t2/t1)/[1/(T2+15+273)-1/(T1+15+273)] * [1/(T3+15+273)-1/(T1+15+273)]}

 

Then we can get the time to 50% and 30% lumen maintenance under different temperature:


Item

Tj=85°C (h)

Tj =70°C (h)

Tj =50°C(h)

Tj =25°C(h)

L50

8312.950414

22756.57306

100144.3113

833055.6622

L30

4277.62127

11709.922

51531.576

428668.0953


Base on this model and combine the standards of IESNA LM-80-2008, LM-82, TM-21 and GB/T, Lisun develop the LISUN LED-80P SYSTEM. This system consist by high and low temperature chamber, AC power supply, DC power supply, multiplex temperature meter, photometer, 2m optical fiber, optical fiber and detector conversion device, light decay prediction software and 19 inch cabinet.