| Model Number: | SKZS-II |
|---|---|
| Brand Name: | Radarking |
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
Application: Used for measuring the volume of consumed water passing through the pipeline and water fee management & control
Features: Low power dissipation, attack resistance, large register capacity, convenient operation and reliable characteristic
Tech. Standard: GB/T 778.1-778.3-2007, JJG 162-2009
Main Functions:
1. Control function: Payment of water fee through card buying or recharging, water fee default behavior avoided
2. Enquiry function: LED Screen displays the recharged volume, remaining volume, accumulated volume, convenient for user's check
3. Protection function: In case of default voltage, power dump or outer magnetic interference valve will shut automatically
4. Alarm alert: Alarm alert timely under situations of under voltage, shortage of the remaining volume, wrong operation and magnetic interference
5. Automatic Statistics: Automatically record the user's actual water consumption status, for the water supply operator's easy management
6. Anti-Blocking: Anti-death circuit & valve anti-blocked patent applied, preventing actuating mechanism's dysfunction
7. Automatic maintenance: Self-checking function built in, checking the valve's flexibility, preventing battery dormancy, checking time set by user voluntarily
8. Data retention: User's data could be kept for ten years, no data loss in case of power dump or cut
Extended Functions:
Signal Remote Transmission: Connected with a outer concentrator, remote signal collection and control are available
Features: Low power dissipation, attack resistance, large register capacity, convenient operation and reliable characteristic
Tech. Standard: GB/T 778.1-778.3-2007, JJG 162-2009
Main Functions:
1. Control function: Payment of water fee through card buying or recharging, water fee default behavior avoided
2. Enquiry function: LED Screen displays the recharged volume, remaining volume, accumulated volume, convenient for user's check
3. Protection function: In case of default voltage, power dump or outer magnetic interference valve will shut automatically
4. Alarm alert: Alarm alert timely under situations of under voltage, shortage of the remaining volume, wrong operation and magnetic interference
5. Automatic Statistics: Automatically record the user's actual water consumption status, for the water supply operator's easy management
6. Anti-Blocking: Anti-death circuit & valve anti-blocked patent applied, preventing actuating mechanism's dysfunction
7. Automatic maintenance: Self-checking function built in, checking the valve's flexibility, preventing battery dormancy, checking time set by user voluntarily
8. Data retention: User's data could be kept for ten years, no data loss in case of power dump or cut
Extended Functions:
Signal Remote Transmission: Connected with a outer concentrator, remote signal collection and control are available
|
DN (mm) |
Max Flow Rate (m3/h) |
Common Flow Rate (m3/h) |
Transitional Flow Rate (m3/h) |
Min Flow Rate (m3/h) |
Digital Display | |
| Max. m3 | Min. m3 | |||||
| 15 | 3 | 1.5 | 120 | 30 | 9999.9 | 0.1 |
| 20 | 5 | 2.5 | 200 | 50 | 9999.9 | 0.1 |
| 25 | 7 | 3.5 | 280 | 70 | 9999.9 | 0.1 |