Type: | DC/AC Inverters |
---|---|
Output Voltage: | 110v/120v/220v/230v/240v |
Input Voltage: | 12v/24v |
Output Type: | Single |
Output Power: | 401 - 600KW |
Model Number: | HYD-600PSWC |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
HYD >> Our advantage
1. work perfectly with enough materials
2. The multiple protection which can be safe used.
3.90% ultrahigh efficiency
4. imported intelligent fan, temperature control design.
5. jamming performance, refused snow and noise
6. The magnesium alloy shell, with light weight and fast heat dissipation.
7. chip technology, the volume is reduced 40-60%, 60-80% weight reduction, reduces the chance of cold dry
>> description and Parameters
Inverter part | |||
Rated power | HYD-600PC+LED | ||
Output continous power | 600W | ||
Output peark power | 1200W | ||
Input | DC input voltage | 12V | 24v |
DC working voltage | 11-14.5V | 21-29V | |
DC input Low
voltage protection |
10V±0.5V | 20V±0.5V | |
DC input Over
voltage protection |
≥14.5V | ≥29V | |
Fuse | 25A*3 | 15A*3 | |
Static current | ≤0.5A | ≤0.5A | |
Output | Output wave form | Pure sine wave | |
Output voltage | 110V±5% | 220V±5% | |
Output frequency | 60Hz±5% | 50Hz±5% | |
Reversing effiency | ≥85% | ||
Overload protection | 600w-720w | ||
Short circuit protection | Yes | ||
Fan start temperature | Start when it turn on | ||
Temperature protection | 70±5℃ | ||
W | ≥5%(Linear load) | ||
Gree LED indicator |
Lighting(working),Flash slowly(Lack voltage) ,
Flash fast (Faul ccur and the unit is in protection situation). |
||
Charing part | |||
Rated power | HYD-600PC | ||
Input | AC input voltage | 110V | 220V |
AC input frequency | 60Hz | 50Hz | |
AC working voltage | 85-135V | 170-265V | |
Charge current | 10A/5A Maximal | ||
Charge voltage | 14.5-16V | 29V-32V | |
Yellow LED indicator |
Lighting(Fully charge),Flashing(charging),
Off(No AC supply or in AC input voltage protection situation). |
HYD >> Test Result
Model | HYD-300P | HYD-600P | HYD-1000P | HYD-2000P | HYD-3000P |
Refrigerator | X | OK | OK | OK | OK |
Air conditioning | X | X | 1P | 1.5P | 2P |
Washing machine | OK | OK | OK | OK | OK |
Vacuum cleaner | OK | OK | OK | OK | OK |
Mixer | OK | OK | OK | OK | OK |
Fan | OK | OK | OK | OK | OK |
Hair dryer drum | OK | OK | OK | OK | OK |
Microwave | X | X | X | OK | OK |
oven | X | X | X | OK | OK |
Pump | X | <200W | <600W | <1200W | <2400 |
Air Compressor | X | <200W | <600W | <1200W | <2400 |
Drill | OK | OK | OK | OK | OK |
Electric kettle | OK | OK | OK | OK | OK |
lamp | OK | OK | OK | OK | OK |
TV | OK | OK | OK | OK | OK |
Speaker | OK | OK | OK | OK | OK |
HYD >> ABOUT US
1.We HYD is a professional Manufacture on power inverters and some consumer electronics since
1992 in shenzhen.The items cover Off-grid tie inverters.Solar controller.Battery Charger.
Solar lights.and so on.
HYD >> Self Answers
Q:What's the surface temperature of the inverter working? If there is security risk?
A:If the The indoor temperature is 25 degrees,the case of the highest temperature 60-70 degrees,It is no security risk,Beacause all the power supply have certainly heat. Our products with high conversion efficiency.which can arriveabove 90%.The heat itself is relatively small,and we have temperature protection.So its safe enough.
.Q:Do your inverter can be used with our battery charger?
A:Yes. As long as our inverter's power bigger than your battery charger.
Q: Does Universal socket means widely inserted into each country?
A: Yes
Q:What kind of problems is out of our product range of replacement?
A: Product appearance of visible damage or non-compliance with damage caused by the use of specifications, such as flooding, privately disassemble, cut lines or access to inappropriate voltage
Q:what's the role of your cooling fan in inverter?
A:The product generates heat discharged to the outside of the casing, acts as heat.
Q:Is it accurate to test by conventional multimeter
A:No.Ordinary multimeter to measure the output voltage is absolutely not accurate, and the error is very large, the general 220V output, measured with a multimeter if only about 170V or so. So be sure to use RMS meter to measure, or power meter.
Q: Why your price higher than others?
A:Currently inverter market was mixed, and some low-price in fact made by small workshop shoddy, shoddy work, the same power of the inverter, and some manufacturers in order to cut costs and reduce the process and material .No set protection and alarm,Use the simple hardware circuit design, and substandard components and vacuity of power, there is a very big security risk. To ensure the safety of you and your family, please choose carefully.
Q: How to devide the inverter accoding to the wave?
A:Modify sine wave, using PWM pulse width modulation, During the inverter process, due to use of professional intelligent circuits and high-power FET, Its greatly reducing power consumption, and increased soft start function effectively ensure the reliability of the inverter, if the electrical quality requirements are not very high, it can meet the requirements of most electrical equipments, moderate prices, but it has a greater harmonic distortion, error-prone when running precision equipment,It can also cause interference to communication devices.
B:Pure sine wave, we uses the coupling circuit design, high efficiency, high stability, high-frequency technology, small size, suitable for all kinds of electrical load can be connected to any electrical devices and inductive load products (eg: cooker, oven, refrigerator , air conditioning, etc.) without any interference (buzzing sound, and snow), its output waveform is the same as AC power
Q:What is a resistive load and the inductive load?
A:The circuit is purely resistive load or can be equivalent to pure resistance, such a load is a resistive load. For example: incandescent, electric fans and other resistive loads.Inductance type loads are inductive loads. For example: motors, transformers, pumps, air conditioning, etc.
Q:What we need to pay attention when use the inverter?
A: Ventilation, heat, water, moisture, not pressure, can not go into the foreign body
Q: How many hours your inverter can load?
A: The Use time depends on the size of the battery capacity .There is a formula:
Hours = battery capacity X battery voltage X 0.8X0.9 / load power
For example: a 12V 100AH batteryload a 220V 100W lights
Working time = 12 (V) X100 (AH) X0.8X0.9 / 100 (W) = 8.6 (h)