| Brand Name: | SOPHENOL |
|---|---|
| Place of Origin: | China (Mainland) |
| Core Size and Type: | Singlemode (G.657.A1 and G.657.A2) |
| Fiber Count: | Simplex (1-fiber) and Duplex (2-fiber) |
| Jacket O.D.: | 2.0 mm |
| Connector Types: | SC/UPC, SC/APC, LC/UPC, LC/APC, FC/UPC, FC/APC, ST/UPC |
Quick Details
Specifications
Protection
Riser and Plenum rated bend-insensitive jacket options available
Available in simplex, dual-round and dual zip-cord configurations
Access
Compact jacket design minimizes cable pile up
Industry standard terminations include ST, SC, FC, LC (ask a Clearfield representative for other connector availability)
Investment
Indoor Bend-Insensitive Fiber Jumper Cables offer an economical solution for deploying fiber in any optical network
Environmentally stable, low-insertion loss, minimal back reflection
All assemblies are 100% tested
Technical Specifications
Applications:
Date centre
Telecommunication networks
CATV
LAN and WAN
FTTX
Broadband network
Riser and Plenum rated bend-insensitive jacket options available
Available in simplex, dual-round and dual zip-cord configurations
Access
Compact jacket design minimizes cable pile up
Industry standard terminations include ST, SC, FC, LC (ask a Clearfield representative for other connector availability)
Investment
Indoor Bend-Insensitive Fiber Jumper Cables offer an economical solution for deploying fiber in any optical network
Environmentally stable, low-insertion loss, minimal back reflection
All assemblies are 100% tested
Technical Specifications
| Core Size and Type | Singlemode (G.657.A1 and G.657.A2) |
| Fiber Count | Simplex (1-fiber) and Duplex (2-fiber) |
| Jacket O.D. | 2.0 mm |
| Cable Types | Indoor Riser |
| Connector Types | SC/UPC, SC/APC, LC/UPC, LC/APC, FC/UPC, FC/APC, ST/UPC |
| Operating Temperature | -40°C to 85°C (-40°F to 185°F) |
| Minimum Performance Specifications for Terminated Singlemode Connectors | |||||
| Connector Type | Ferrule Material | Polish Type | Ins. Loss Typical (dB) | Max Ins. Loss (db) | Min. Ret. Loss (db) |
| ST | Ceramic | UPC | 0.15 | 0.20 | 55.00 |
| SC | Ceramic | UPC | 0.15 | 0.20 | 55.00 |
| FC | Ceramic | UPC | 0.15 | 0.20 | 55.00 |
| LC | Ceramic | UPC | 0.15 | 0.20 | 55.00 |
| SC | Ceramic | APC | 0.15 | 0.20 | 65.00 |
| FC | Ceramic | APC | 0.15 | 0.20 | 65.00 |
| LC | Ceramic | APC | 0.15 | 0.20 | 65.00 |
| Minimum Performance Specifications for Terminated Multimode Connectors | ||||
| Connector Type | Ferrule Material | Polish Type | Ins. Loss Typical (dB) | Max. Ins. Loss (db) |
| ST | Ceramic | PC | 0.25 | ≤0.50 |
| SC | Ceramic | PC | 0.25 | ≤0.50 |
| FC | Ceramic | PC | 0.25 | ≤0.50 |
| LC | Ceramic | PC | 0.25 | ≤0.50 |
Applications:
Date centre
Telecommunication networks
CATV
LAN and WAN
FTTX
Broadband network