| Application: | Telecommunications |
|---|---|
| Type: | On-line |
| Output Voltage: | 208/220/230/240VAC |
| Weight: | 21kg |
| Protection: | Overcurrent |
| Phase: | Single Phase |
| Model Number: | 0004 |
| Brand Name: | upsen |
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
Key Features
? True double-conversion on line UPS
? DSP technology guarantees high performance
? Output power factor 0.8
? Active input power factor correction 0.99
? 50Hz/60Hz frequency converter mode
? Standard backup UPS and long backup UPS in one integrated unit
? Adjustable battery number from 16 pcs to 20 pcs
? Adjustable charging current via LCD or software (0.5A~6A)
? Wide input voltage range (110-300 VAC)
? Emergency power off function (EPO)
? 3-stage extendable charging design for optimized battery performance
? Maintenance bypass available
? SNMP/USB/RS-232 communications
Technical Specification
| GREEN STAR 6K/10K ONLINE UPS SPECIFICATION | |||
| MODEL | G6K (L) | G10K (L) | |
| PHASE | 1 phase in / 1 phase out | ||
| CAPACITY | 6000 VA / 4800 W | 10000 VA / 8000 W | |
| INPUT | |||
| Nominal Voltage | 208/220/230/240VAC | ||
| Voltage Range | Low Line Loss |
110 VAC ± 3% at 50% Load 176 VAC ± 3% at 100% Load |
|
| Low Line Comeback |
120 VAC ± 3% at 50% Load 186 VAC ± 3% at 100% Load |
||
| High Line Loss | 300 VAC ± 3% | ||
| High Line Comeback | 290 VAC ± 3% | ||
| Frequency Range | 46 Hz ~ 54 Hz or 56 Hz ~ 64 Hz | ||
| Power Factor | ≧ 0.99 @ 100% load | ||
| OUTPUT | |||
| Nominal Voltage | 208/220/230/240VAC | ||
| AC Voltage Regulation | ± 1% | ||
| Frequency Range (Synchronized Range) | 46 Hz ~ 54 Hz or 56 Hz ~ 64 Hz | ||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||
| Current Crest Ratio | 3:1 (max.) | ||
| Harmonic Distortion |
≦ 3 % THD (Linear Load) ≦ 6 % THD (Non-linear Load) |
||
| Transfer Time |
Bypass to Inverter (Line mode) |
Zero | |
|
Inverter to Bypass (Line mode) |
Zero | ||
| Waveform (Batt. Mode) | Pure Sinewave | ||
| EFFICIENCY | |||
| Line Mode | 89% | 90% | |
| Battery Mode | 88% | 89% | |
| BATTERY | |||
| Standard Model | Battery Type | 12 V / 7 AH | 12 V / 9 AH |
| Numbers | 16 | 16 | |
| Typical Recharge Time | 9 hours recover to 90% capacity | ||
| Charging Current |
Default:1.0 A ± 10%, Max.:2.0A ± 10% |
Default:1.0 A ± 10%, Max.:2.0A ± 10% |
|
| Float Charging Voltage | 218.4 VDC ± 1% | ||
| Long-run Model | Battery Type | Depending on applications | |
| Numbers | 16-20** (adjustable) | ||
| Charging Current | Default:4.0 A ± 10%, Max.:6.0A ± 10% |
Default:4.0 A ± 10%, Max.:6.0A ± 10% |
|
| Float Charging Voltage | 273 VDC ± 1% (based on 20 pcs batteries) | ||
| INDICATORS | |||
| LCD Panel |
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
||
| ALARM | |||
| Battery Mode | Sounding every 4 seconds | ||
| Overload | Sounding twice every second | ||
| Fault | Continuously sounding | ||
| PHYSICAL | |||
| Standard Model |
Dimension, D X W X H (mm) |
369 x 190 x 688 | 442 x 190 x 688 |
| Net Weight (kgs) | 60 | 75 | |
| Long-run Model |
Dimension, D X W X H (mm) |
369 x 190 x 318 | 442 x 190 x 318 |
| Net Weight (kgs) | 21 | 23 | |
| ENVIRONMENT | |||
| Operation Humidity | 0-95 % RH @ 0- 40°C (non-condensing) | ||
| Noise Level | Less than 55dBA @ 1 Meter |
Less than 58dBA @ 1 Meter |
|
| MANAGEMENT | |||
| Smart RS-232/USB |
Supports Windows? 2000/2003/XP/Vista/2008, Windows? 7/8, Linux, Unix, and MAC |
||