| Dimensions: | 70mm75mm30mm |
|---|---|
| Model Number: | MEWOI2000E |
| Brand Name: | MEWOI |
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
INTRODUCTION
|
Safe and Time Saving |
Traditional phase sequence measurement methods must poke the three-phase wire terminal, and connect the three bare alligator clips or test pins of phase sequence meters to the three bare firing lines, while MEWOI2000E uses clamp non-contact measurement, without taking off the wire and no need to contact high-voltage bare fire-wire, the test can be made by directly clamping the three-phase insulating sheath by three super-sensitive high-insulated clamps. Conducting measurement on sheathed cable significantly improves the safety of field testing, effectively protect the operator's personal safety and increase productivity! |
|
Convenient Operation |
Instrument base plate is provided with magnet, instrument can adsorbed on the metal shell when testing, the operation more convenient. |
|
Multi-Purpose |
In addition to phase sequence detection, it also has the functions of live wire examination, simple power detection, fire-wire identification, phase deficiency determination, break location detection, DC line break and line maintenance, equivalent to 3 induction electric pens. |
|
Dynamic Display |
LED dynamic display, intuitive and clear |
|
Sensitive and reliable |
More sensitive MEWOI2000E clamp, can even sense the AC voltage signal as low as a few Volts, with a wider range of live electricity. |
|
Beautiful and scientific |
The three clamps of MEWOI2000E are in three colors, Red, Yellow and Green; It is more in line with the distinction of three-phase line, and more scientific and artistic overall appearance. |
|
Ultra-low Power Consumption |
MEWOI2000E has a better power-saving performance with the maximum rated power of 100mVA. |
TECHNICAL SPECIFICATION
|
Functions |
Phase detection (normal phase, reverse phase and phase deficiency), Live wire examination, Simple Power detection, Breakpoint location and Line maintenance. |
|
Power Supply |
DC3V AA Mn batteries (R6P) ×2 PCS, Continuously working for 200 hours |
|
AC Voltage Range(V) |
AC0~600V, 40~70Hz (Sine Wave Continuous Input) |
|
Clamp Wire Size |
Diameter ?10-?40mm |
|
LED Display |
[Positive Phase Sequence] The four phase-sequence lamps blink in order (clockwise). [Negative Phase Sequence] The four phase-sequence lamps blink in order (counterclockwise). [Line-voltage Indication]L1, L2, L3 lamp light up. [Default Phase]L1/L2/L3 lamp is off. [Open Circuit]L1/L2/L3 lamp is off. |
|
Power On Indication |
Power On indication light turns on |
|
Auto Power off |
After 5minutes, the meter automatically cut off power supply. |
|
Meter Dimension |
Width, height, thickness 70mm*75mm*30mm |
|
Clamp Lead Length |
0.5m |
|
Meter Weight |
180g (with battery) |
|
Working Temperature and Humidity |
-10℃~55℃; below 80%rh |
|
Storage Temperature and Humidity |
-20℃~60℃; below 90%rh |
|
Maximum Measured Voltage |
AC600V |
|
Dielectric Strength |
5.4kVrms |
|
Maximum rated Power |
100mVA |
|
Safety Provisions |
EN61010-1: 2001, EN61010-031: 2002, Pollution level 2, CAT Ⅲ(600V), Transient over-voltage 6000V |
|
Accessories |
Meter: 1 Piece; Carrying case; 1 Piece. |
SELECTION GUIDE
| Model | Function | Display | Max Dimension to be clamped | Dimension (mm) |
Range |
Capacity |
Other |
| MEWOI2000D | Phase detection (Normal, Reverse) |
LED |
Φ1.6~16mm | 70*75*30 |
AC70-1000V |
Continuously using 200 hours | Base plate with magnet,more convenient |
| MEWOI2000E |
Φ10~40mm |