Quick Details

Weight: 2kg
Dimensions: 75mm170mm30mm
Measuring Current Range: AC 0.00A-20KA(50/60Hz)
Display Type: Analog and Digital
Model Number: MEWOI9000G
Brand Name: MEWOI
Place of Origin: China (Mainland)

Specifications

INTRODUCTION

MEWOI9000G flexible high current clamp / logger is specially designed for field-line testing, monitoring, recording AC leakage current and Large current, It consists of host, flexible current clamps, monitoring software, communication lines and other components. Widely used in electric power, telecommunications, meteorology, railroad, oilfield, construction, measurement, research and teaching departments, industrial and mining enterprises and other fields. Particularly suitable for cable-intensive places, the wall transformer core grounding current test, thick wire cable test, relay protection , frequency conversion, semiconductor switches, electronic power conversion equipment, arc welding and other serious signal distortion current testing industrial environments.

Flexible current clamp (Rockwell coil), apply to advanced Rockwell coil (or Rogowski coil) technology, is a uniform circular coil wound on a non-ferromagnetic material, no hysteresis effect is almost zero phase error, no magnetic saturation, high linearity, strong anti-interference ability. The output signal is a differential current over time, by integrating the output voltage signal , you can restore the real input current, the current measurement range from milliamps to tens of thousands of Amps. Flexible current clamp coil is without any exposed metal conductor, non-contact measuring, safe and fast; its small size, light weight, attractive appearance, soft and flexible, adapted to the environment and the narrow cable-intensive sites; high accuracy, reliability, response frequency bandwidth, users can customize the length of the coil according to actual demand.

Host embedded in English interface, suitable for engineering and technical personnel of different countries. LCD display, at a glance. While having a relatively large storage space, can store 4200 sets of data, also has an automatic time setting function storage interval, the settings ranges from 1 to 60 minutes.

Monitoring software supports on-line real-time monitoring and historical inquiry, dynamic display, wave indication; has a maximum, minimum, average indication; with alarm value setting and alarm indication; historical data read, access, store, sort, generate curves, printing etc.

TECHNICAL SPECIFICATION

Functions
Field-line testing, monitoring, recording AC leakage current and Large current
Power source
 DC6V, alkaline battery LR06 1.5V×4
Testing Method
 By integrating the output voltage signal , you can restore the real input current
Inner diameter (φ300mm(Optional,Can be customized)
Range
 0.00A-20.000KA
Resolution
 10mA
Accuracy
 ±2%±3dgt(cable in the center of the coil, 23℃±2℃)
Coil Length
 1000mm((Can be customized))
Current Frequency
 50Hz~60Hz(The measured current frequency, Automatic Identification)
LCD Display
 LCD: 128dots×64dots
LCD Size
44mm×27mm
Host Dimension

W*L*H75mm×170mm×30mm

Diameter
 φ7.5mm(Suitable for narrow cable-intensive sites)
Weight Host(240g),Flexible Coil(150g)
Electric field interference
  no magnetic saturation, high linearity, strong anti-interference ability
Position error cable in the center of the coil,don't put the cable at the split area,error doubles or more at the split area
Sampling Rate 2 samples/s
Data storage
 4200 sets (data loss does not occur after power failure or replacing the battery)
Time Setting
 Recording internal adjustable from 1 to 60 min, If set to 0 min, the auto-store function is turned off
Recording Time
 Continuously operate for about 100hours at the power-saving mode
Line Voltage
 Line with a voltage up to AC600V
Overflow Display
 The " OL" symbol is displayed when a measured value is beyond the measurement range
Battery. Voltage
 A Low-Battery symbol is displayed and the user should replace the battery with a new one when the battery voltage drops to 4.6V  to 4.8V. In this case, the measured values are still accurate. 
Rated Power
 about 5mA at the power-saving mode, maximum current consumption: 20mA
Lead Length
 2m
Temperature and Humidity
 Working: -10℃~40℃; below 80%rh
 Storage: -10℃~60℃; below 70%rh
Insulation Resistance
 Higher than 100MΩ, 1000V
Safety Codes
 IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard)
Accessories
 Host: 1 PCS, Flexible Coil: 1 PCS, Instrument bag: 1 PCS, RS232 Com-cable:1 PCS; Software Disk: 1 PCS,Batteries:LR06: 4pcs
Ⅱ.SELECTION GUIDE 1

High Accuracy leakage current Clamp Meter/Tester

Click "Blue" marked MODEL NO.to view the spec

Model

Range

Resolution

Clamp size

Data Storge RS232

MEWOI7000



φ7mm

99sets

MEWOI7100

AC/DC  0.0A~1000A

0.1A

30mm×35mm

99sets

MEWOI7200

AC/DC  0mA~60A

1mA

25mm×30mm

99sets

MEWOI7300

AC  0.000mA~60.00A

1uA

25mm×30mm

99sets

MEWOI7300E

DC  0.00mA~60.00A

0.01mA

25mm×30mm

99sets

MEWOI7500

AC  0.00mA~300.0A

0.01mA

35mm×40mm

99sets

MEWOI7600

AC  0mA~600A

1mA

35mm×40mm

99sets

MEWOI7800

AC  0.00mA~1200A

0.01mA

φ68mm

99sets

MEWOI7800E

AC 0.0A~1500A ,DC 0.0A~2000A

0.1A

φ68mm

99sets

SELECTION GUIDE 2

For Flexible Coil Leakage Current Monitoring Recorder/Logger

Click "Blue" marked MODEL NO.to view the Spec

Model No. Range Accuracy: Clamp mouth Coli Length LCD display Data Storage Data upload RS232 interface Working Time
MEWOI9000G AC 0.00A~20KA(50/60Hz) AC 0.01A Φ300mm 1000mm 44mm×27mm 4200sets 100hours