| Usage: | Impact Testing Machine |
|---|---|
| Power: | Electronic |
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
Technical Parameters
|
Model |
TH-100 |
TH-225 |
TH-500 |
TH-800 |
TH-1000 |
||||
|
Internal dimension (mm) |
450*450*500 |
500*600*750 |
800*700*900 |
800*1000*1000 |
1000*1000*1000 |
||||
|
Overall dimension (mm) |
1050*880*1440 |
1050*1020*2000 |
1320*1320*2170 |
1470*1520*2315 |
1670*1520*2315 |
||||
|
Technical structure |
|||||||||
|
Temperature range |
-20℃~+150 ℃ |
||||||||
|
Low type |
Ⅰ: -40℃ Ⅱ:-60℃ Ⅲ: -70℃ |
||||||||
|
Humidity range |
20% ~ 98% RH |
||||||||
|
Temperature fluctuations |
± 0.5 ℃ |
||||||||
|
Temperature deviation |
± 2.0 ℃ |
||||||||
|
Humidity deviation |
± 2.5% RH |
||||||||
|
Heating rate |
3 ℃ / min |
||||||||
|
Cooling rate |
1 ℃ / min |
||||||||
|
Control system |
|||||||||
|
Controller |
5.7" programmable color display touch screen controller |
||||||||
|
Controller optional languages are English,German,French,Russian,Spanish,Korean,Japanese. |
|||||||||
|
PC Link with software, R-232 interface |
|||||||||
|
Temperature Sensor |
PTR Platinum Resistance PT100Ω/MV A-class |
||||||||
|
Temperature Resolution |
± 0.001 ℃ |
||||||||
|
Humidity sensor |
Dry and wet bulb sensor |
||||||||
|
Humidity Resolution |
± 1%RH |
||||||||
|
Heating system |
Independent Nichrome electronic heating system |
||||||||
|
Cooling system |
French TECUMSEH compressor |
||||||||
|
Humidification system |
External isolation, stainless steel surface evaporation humidifier |
||||||||
|
Dehumidification system |
Evaporator |
||||||||
|
Water supply system |
Automatic water supply, Water purification system, Water saving |
||||||||
|
Circulatory system |
Cold resistance and low noise centrifugal wind wheel |
||||||||
|
Material |
|||||||||
|
Exterior material |
Steel Plate with protective coating |
||||||||
|
Interior material |
SUS304 stainlesssteel |
||||||||
|
Insulation window |
Double thermostability silicone rubber sealing |
||||||||
|
Standardconfiguration |
1 Cable hole (Φ 50,) cover, 2 sets of shelf, 2 protector tubes, 1 overflow water tube,1 copy of operating specification |
||||||||
|
Timing Function |
0.1~999.9 (S,M,H) settable |
||||||||
|
Nominal Power |
4500W |
6500W |
7000W |
9500W |
11000W |
||||
|
Power Supply |
AC220V 50HZ |
AC220V 50HZ |
AC380V 50HZ |
AC380V 50HZ |
AC380V 50HZ |
||||
|
Environmental conditional |
5℃~+40 ℃ ≤85% RH |
||||||||
|
Standard |
IEC60068-2-1;IEC60068-2-2;GB/T2423.1-2001; GB/T2423.2-2001 |
||||||||