Product Main

Quick Details

Application: Networking
Type: On-line
Output Voltage: 220Vac
Weight: 9.8KG
Protection: Overvoltage
Phase: Single Phase
Model Number: HA1-3K
Brand Name: MONA
Place of Origin: China (Mainland)
Capacity: 1Kva, 2Kva, 3Kva
Wave: Pure Sine Wave
Power Factor: 0.9
Transfer Time: 0
Battery: lead acid battery
Display: LCD
Frequency: 50Hz / 60Hz
Transformer: Transformerless
Interface: RS232, RJ45, RJ11, SNMP
Application: Networking , Computer Room, LAN

Specifications

 

Feature:
True double-conversion
Wide input voltage range (110-300 VAC)
Input power factor correction 0.99
Output Power Factor 0.9
Maximun 12A charger for long-run models
Charger current can be seting by LCD
50Hz/60Hz frequency converter mode
Emergency power off function (EPO)
Eco mode operation for energy saving (ECO)
Generator compatible
SNMP/USB/RS232 multiple communications
Smart battery charger design for optimized battery performance
Selectable output voltage: 200,208,220,230,240VAC
HA Series Pure Sine Wave 1Kva 2Kva 3Kva Online UPS PF0.9
MODEL HA1K HA1KS HA2K HA2KS HA3K HA3KS
PHASE Single phase with ground
Capacity (VA/Watts) 1000VA / 900W 2000VA / 1800W 3000VA / 2700W
INPUT 
Nominal voltage  200/208/220/230/240VAC
Operating voltage range 115~295Vac
Operating frequency range 40-70Hz
Power factor 0.99
Generator input Support
OUTPUT
Output voltage 200/208/220/230/240Vac
Power factor 0.9
Voltage regulation ±1%
Frequency Line Mode 47-53Hz or 57-63Hz
Bat. Mode (50/60±0.1)Hz
Crest factor 3:01
Harmonic distortion (THDv) ≤3% THDwith linear load,  ≤6% THD with non linear load
Waveform  Pure Sinewave
Transfer time Zero
Efficiency Line mode  88% 92% 92%
Batt mode 85% 87% 89%
BATTERY
Battery Type 12V9AH depends on 12V9AH depends on 12V9AH depends on
external batteries external batteries external batteries
Numbers 2 2 4 4 6 6
Backup time Long run unit depends on the capacity of external batteries
Typical recharge time (standard model) 4 hours recover to 90% capacity (Typical)
Charging voltage 27.4 VDC ±1% 27.4 VDC ±1% 54.7 VDC ±1%  54.7 VDC ±1% 82.1 VDC ±1%  82.1 VDC ±1%
Charge current  1A 12A max, can be 1A 12A max, can be  1A 12A max, can be 
setting by LCD setting by LCD setting by LCD
SYSTEM FEATURES
Line Mode Ambient Temp.<35
Battery Mode 105%~110%: UPS shuts down after 10 mins at batt mode or transfer to bypass when the utility is normal
110%~130%: UPS shuts down after 1minute at batt mode or transfer to bypass when the utility is normal
>130%:UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal
35<Ambient Temp.<40
105%~110%: UPS shuts down after 1 mins at batt mode or transfer to bypass when the utility is normal
>110%:UPS shuts down after 3 seconds at batt mode or transfer to bypass when the utility is normal
Short Circuit Hold Whole System
Overheat Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
Low battery voltage Alarm and Switch off
EPO (optional) Shut down UPS immediately
Audible & Visual alarms Line Failure, Battery Low, Overload, System Fault
Comunication interface USB(or RS232), SNMPcard(optional), Relay card (optional)
ENVIRONMENTAL
Operating temperature 0~40
Storage temperature -25~55
Humidity range 20-90 % RH @ 0- 40°C (non-condensing)
Altitude < 1500m
Noise level Less than 50dBA at 1 Meter
PHYSICAL
Dimension W×H×D(mm) 144*209*293 191*337*460 144*209*293
Net Weight (kg) 9.8 4 17 6.7 27.6 7.3
*S is long backup verstion