Feature:
|
|
True double-conversion
|
|
Wide input voltage range (110-300 VAC)
|
|
Input power factor correction 0.99
|
|
Output Power Factor 0.9
|
|
Maximun 12A charger for long-run models
|
|
Charger current can be seting by LCD
|
|
50Hz/60Hz frequency converter mode
|
|
Emergency power off function (EPO)
|
|
Eco mode operation for energy saving (ECO)
|
|
Generator compatible
|
|
SNMP/USB/RS232 multiple communications
|
|
Smart battery charger design for optimized battery performance
|
|
Selectable output voltage: 200,208,220,230,240VAC
|
|
|
|
|
|
|
|
|
|
|
HA Series Pure Sine Wave 1Kva 2Kva 3Kva Online UPS PF0.9
|
|
MODEL
|
HA1K
|
HA1KS
|
HA2K
|
HA2KS
|
HA3K
|
HA3KS
|
|
PHASE
|
Single phase with ground
|
|
Capacity (VA/Watts)
|
1000VA / 900W
|
2000VA / 1800W
|
3000VA / 2700W
|
|
INPUT
|
|
Nominal voltage
|
200/208/220/230/240VAC
|
|
Operating voltage range
|
115~295Vac
|
|
Operating frequency range
|
40-70Hz
|
|
Power factor
|
0.99
|
|
Generator input
|
Support
|
|
OUTPUT
|
|
Output voltage
|
200/208/220/230/240Vac
|
|
Power factor
|
0.9
|
|
Voltage regulation
|
±1%
|
|
Frequency
|
Line Mode
|
47-53Hz or 57-63Hz
|
|
Bat. Mode
|
(50/60±0.1)Hz
|
|
Crest factor
|
3:01
|
|
Harmonic distortion (THDv)
|
≤3% THDwith linear load, ≤6% THD with non linear load
|
|
Waveform
|
Pure Sinewave
|
|
Transfer time
|
Zero
|
|
Efficiency
|
Line mode
|
88%
|
92%
|
92%
|
|
Batt mode
|
85%
|
87%
|
89%
|
|
BATTERY
|
|
Battery Type
|
12V9AH
|
depends on
|
12V9AH
|
depends on
|
12V9AH
|
depends on
|
|
external batteries
|
external batteries
|
external batteries
|
|
Numbers
|
2
|
2
|
4
|
4
|
6
|
6
|
|
Backup time
|
Long run unit depends on the capacity of external batteries
|
|
Typical recharge time (standard model)
|
4 hours recover to 90% capacity (Typical)
|
|
Charging voltage
|
27.4 VDC ±1%
|
27.4 VDC ±1%
|
54.7 VDC ±1%
|
54.7 VDC ±1%
|
82.1 VDC ±1%
|
82.1 VDC ±1%
|
|
Charge current
|
1A
|
12A max, can be
|
1A
|
12A max, can be
|
1A
|
12A max, can be
|
|
setting by LCD
|
setting by LCD
|
setting by LCD
|
|
SYSTEM FEATURES
|
|
Line Mode
|
Ambient Temp.<35℃
|
|
Battery Mode
|
105%~110%: UPS shuts down after 10 mins at batt mode or transfer to bypass when the utility is normal
|
|
110%~130%: UPS shuts down after 1minute at batt mode or transfer to bypass when the utility is normal
|
|
>130%:UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal
|
|
35℃<Ambient Temp.<40℃
|
|
105%~110%: UPS shuts down after 1 mins at batt mode or transfer to bypass when the utility is normal
|
|
>110%:UPS shuts down after 3 seconds at batt mode or transfer to bypass when the utility is normal
|
|
Short Circuit
|
Hold Whole System
|
|
Overheat
|
Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
|
|
Low battery voltage
|
Alarm and Switch off
|
|
EPO (optional)
|
Shut down UPS immediately
|
|
Audible & Visual alarms
|
Line Failure, Battery Low, Overload, System Fault
|
|
Comunication interface
|
USB(or RS232), SNMPcard(optional), Relay card (optional)
|
|
ENVIRONMENTAL
|
|
Operating temperature
|
0℃~40℃
|
|
Storage temperature
|
-25℃~55℃
|
|
Humidity range
|
20-90 % RH @ 0- 40°C (non-condensing)
|
|
Altitude
|
< 1500m
|
|
Noise level
|
Less than 50dBA at 1 Meter
|
|
PHYSICAL
|
|
Dimension W×H×D(mm)
|
144*209*293
|
191*337*460
|
144*209*293
|
|
Net Weight (kg)
|
9.8
|
4
|
17
|
6.7
|
27.6
|
7.3
|
|
*S is long backup verstion
|