Application Field
|
Computers
|
Communication
|
Home Appliance, such as Fans and lights
|
Office, like computers with Printers
|
Aeronaoutics & Astronautics
|
Electronic & Telecom
|
Army Technology
|
Securities System/ Monitoring / Alarm
|
Sensitive Electronic Equipment
|
Wind Power System
|
Industrial Equipment
|
Military
|
Medical Systems
|
Networking
|
Instrumentation
|
Servers and so on
|
|
Description:
|
Double conversion
|
Pure Sine Wave
|
Rack and tower convertible
|
High input power factor
|
High reliability and performance
|
Full protection function & Automatic bypass
|
Wide input voltage range
|
Intelligent RS232 Communication Port
|
ECO & EPO function
|
THDI<5% (6KVA & 10KVA)
|
UPS management software(optional)
|
SNMP or USB or dry contactor(optional)
|
Large LCD + LED display
|
|
|
|
|
|
|
|
|
|
Online Low Frequency UPS 3-30Kva Single Phase Uninterrupted Power Supply
|
Model# (1 phase input 1 phase output)
|
LA11-3K
|
LA11-6K
|
LA11-10K
|
LA11-15K
|
LA11-20K
|
LA11-30K
|
Input Mains
|
Rated Voltage
|
220V(Line Voltage)
|
Rated Voltage & Range
|
220V±25%
|
Frequency & Range
|
46Hz-54Hz, 56Hz-64Hz
|
Bypass Input
|
Rated Voltage
|
220V
|
Rated Voltage & Range
|
220V±25%
|
Frequency & Range
|
46Hz-54Hz, 56Hz-64Hz
|
Output
|
Rated Power
|
3KVA/2.4KW
|
6KVA/4.8KW
|
10KVA/8KW
|
15KVA/12KW
|
20KVA/16KW
|
30KVA/24KW
|
Rated Voltage
|
220V(Line Voltage)
|
Rated Voltage & Stability
|
200/208/220/230/240VAC Phase Voltage
|
THDV
|
Linear Load
|
≤3%
|
Non-linear Load
|
≤8%
|
Output Power factor
|
0.8(Lag)
|
Tracking Fruquency & Range
|
46Hz-54Hz, 56Hz-64Hz
|
Fruquency & Stability
|
(50±0.1)Hz, (60±0.1)Hz
|
(Battery Inverter)
|
Overload Capability
|
Less than 105%±5% for overload alarm;
|
105%±5%~125%±5% for 2 minutes;
|
125%±5%~150%±5% for 30 second;
|
More than 150%±5% for 0.5 second;
|
Switching time (Normal mode)
|
0ms
|
System
|
System Efficiency(Linear Load)
|
≥80%
|
≥82%
|
≥85%
|
≥86%
|
≥87%
|
≥88%
|
Display
|
LCD+LED
|
EMS/EMI
|
Transmission
|
IEC EN62040-02
|
Radiation
|
Immunity
|
IEC 61000-4-2.4.5 Level IV, IEC61000-4-3 Level III
|
Safety Requirements
|
GB4943-2001/IEC62040-1
|
Noise Level(1M)
|
≤55dB
|
Isolate Impedance(Ω)
|
>2M(500VDC)
|
Surge Current Protection
|
IEC60664-1 IV
|
Environment
|
Operating Temperature
|
0oC - 40oC
|
Elevation
|
<1000m
|
Storing Temperature
|
-15oC - 45oC
|
Operation Humidity
|
20% - 95%
|
Battery
|
192VDC
|
UPS Size(W*H*D)mm
|
260*501*533
|
260*717*560
|
370*900*655
|
455*1055*830
|
Package Size(W*H*D)mm
|
390*640*680
|
320*840*620
|
450*1054*730
|
515*1215*915
|
Net Weight(kg)
|
40
|
58
|
62
|
155
|
160
|
Gross Weight(kg)
|
43
|
76
|
80
|
170
|
175
|
Note: It is to be noted that all these parameters are subject to change without notice.
|