Product Main

Quick Details

Application: Medical
Type: On-line
Output Voltage: 220Vac
Weight: 40KG
Protection: Overcurrent
Phase: Single Phase
Model Number: LA11 3-30K
Brand Name: MONA
Place of Origin: China (Mainland)
Type: Online Low Frequency UPS
Wave: Pure Sine Wave
Transfer Time: 0
Power Factor: 0.8
Frequency: 50HZ/60HZ
Battery: Lead Acid Battery
Battery Voltage: 192Vdc
Output Voltage: 220Vac
Transformer: Isolated Transformer
Technology: DSP

Specifications

Application Field
Computers
Communication
Home Appliance, such as Fans and lights
Office, like computers with Printers
Aeronaoutics & Astronautics
Electronic & Telecom
Army Technology
Securities System/ Monitoring / Alarm
Sensitive Electronic Equipment
Wind Power System
Industrial Equipment
Military
Medical Systems
Networking
Instrumentation
Servers and so on
Description:
Double conversion
Pure Sine Wave
Rack and tower convertible
High input power factor
High reliability and performance
Full protection function & Automatic bypass
Wide input voltage range
Intelligent RS232 Communication Port
ECO & EPO function
THDI<5% (6KVA & 10KVA)
UPS management software(optional)
SNMP or USB or dry contactor(optional)
Large LCD + LED display
Online Low Frequency UPS 3-30Kva Single Phase Uninterrupted Power Supply
Model# (1 phase input 1 phase output) LA11-3K LA11-6K LA11-10K LA11-15K LA11-20K LA11-30K
Input Mains Rated Voltage 220V(Line Voltage)       
Rated Voltage & Range 220V±25%       
Frequency & Range 46Hz-54Hz, 56Hz-64Hz       
Bypass Input   Rated Voltage 220V       
Rated Voltage & Range     220V±25%     
 Frequency & Range  46Hz-54Hz,   56Hz-64Hz       
   Output           Rated Power     3KVA/2.4KW 6KVA/4.8KW 10KVA/8KW 15KVA/12KW 20KVA/16KW 30KVA/24KW
Rated Voltage   220V(Line   Voltage)       
Rated Voltage & Stability  200/208/220/230/240VAC Phase Voltage       
THDV      Linear Load     ≤3%    
Non-linear Load     ≤8%      
Output   Power factor       0.8(Lag)     
Tracking Fruquency & Range 46Hz-54Hz, 56Hz-64Hz       
Fruquency  & Stability (50±0.1)Hz, (60±0.1)Hz       
(Battery Inverter)   
Overload Capability    Less than 105%±5% for overload alarm;
    105%±5%~125%±5% for 2   minutes;
125%±5%~150%±5% for 30 second;
More than 150%±5% for 0.5 second;      
Switching time (Normal mode)         0ms   
  System          System Efficiency(Linear Load)      ≥80%   ≥82% ≥85%     ≥86% ≥87%   ≥88%  
Display    LCD+LED       
EMS/EMI     Transmission   IEC EN62040-02             
Radiation  
Immunity   IEC 61000-4-2.4.5 Level IV, IEC61000-4-3 Level III       
Safety Requirements    GB4943-2001/IEC62040-1       
Noise Level(1M)         ≤55dB   
Isolate Impedance(Ω)     >2M(500VDC)      
Surge Current Protection  IEC60664-1 IV       
Environment      Operating Temperature  0oC   - 40oC       
Elevation    <1000m       
Storing Temperature    -15oC   - 45oC       
Operation Humidity    20% - 95%       
Battery     192VDC       
UPS Size(W*H*D)mm      260*501*533   260*717*560   370*900*655    455*1055*830
Package Size(W*H*D)mm     390*640*680 320*840*620    450*1054*730    515*1215*915
Net Weight(kg)      40 58   62 155    160
Gross Weight(kg)      43  76  80  170 175  
Note: It is to be noted that all these parameters are subject to change without notice.