Product Main

Quick Details

Application: Telecommunications
Type: On-line
Output Voltage: 220Vac
Weight: 280KG
Protection: Lightning
Phase: Three Phase
Model Number: LA31 6-40K
Brand Name: MONA
Place of Origin: China (Mainland)
Type: Industrial UPS
Wave: Pure Sine Wave
Transfer Time: 0
Power Factor: 0.8
Frequency: 50HZ/60HZ
Battery: Lead acid battery
Output: 220Vac
Transformer: Isolated Transformer
Technology: DSP
Application: Medical etc

Specifications

Application Field:
PC Computers
Communications
Home Appliance, such as Fans and lights
Office, like soho with Printers
Aeronaoutics & Astronautics
Electronic & Telecom
Army Technology
Security System / Monitoring / Alarm
Inductive Electronic Equipment (with motor inside or something similar)
Wind Power System / Solar Power System
Industrial Equipment
Military
Medical Systems
Networking
Instrumentation
Servers and so on
Description:
IGBT / DSP technology
Double conversion
Ture Sine Wave
Rack and tower convertible
High input power factor
High reliability and performance
Full protection function & Automatic bypass
Wide input voltage range
Intelligent RS232 Communication Port
ECO & EPO function
THDI<5% (6KVA & 10KVA)
UPS management software(optional)
SNMP or USB or RJ45 RJ11 or dry contactor(optional)
Large LCD + LED display
LA31 6-40Kva Online Low Frequency Uninterruptible Power System (Three Phase In single Phase Out)
MODEL (3 Phase Input 1 Phase Output UPS) LA31-6K LA31-10K LA31-15K LA31-20K LA31-30K LA31-40K
Input Mains Rated Voltage(V) 380V(Line Voltage)
Rated Voltage & Range(V) 380V±25%
Frequency & Range(Hz) 46Hz-54Hz
Bypass Input Rated Voltage(V) 220V(Line Voltage)
Rated Voltage & Range(V) 380V±25%
Frequency & Range(Hz) 46Hz-54Hz
Output Rated Power 6KVA/4.8KW 10KVA/8KW 15KVA/12KW 20KVA/16KW 30KVA/24KW 40KVA/32KW
Rated Voltage(V) 220V(Line Voltage)
Rated Voltage & Stability 220V±2%
THDV ≤3%
≤10%
Output Power factor 0.8(Lag)
Tracking Fruquency & Range(Hz) 46Hz~64Hz
Fruquency & Stability(Battery Inverter) (50+0.1)Hz/60+0.1)Hz
Overload Capability Less than 105%±5% for overload alarm;
105%±5%~125%±5% for 2 minutes;
125%±5%~150%±5% for 30 second;
More than 150%±5% for 0.5 second;
Converting time(Normal Mode) <1mS
Converting time(ECO Mode) <25mS
System System Efficiency(Linear Load) ≥82% ≥87% ≥82% ≥88%
Display LCD+LED
EMS/EMI Transmission/Radiation IEC EN62040-02
Resisting Interference IEC 61000-4-2.4.5 Level IV, IEC61000-4-3 Level III
Safety Requirements GB4943-2001/IEC62040-1
Noise Level(1M) ≤55dB
Isolate Impedance(Ω) >2M(500VDC)
Surge Current Protection IEC60664-1 IV
Environment Operating Temperature 0 - 40
Elevation <1000m
Storing Temperature -15 - 45
Operation Humidity 20% - 95%
Battery 192VDC 384VDC
UPS Size(W x H x D)mm 260x717x560 370x900x655 455x1055x830 455x1045x830 515x1135x830
Package Size(WxHxD)mm 320x840x620 450x1054x730 515x1215x915 515x1215x915 575x1305x915
*Specifications are subject to change without prior notice.