Quick Details

Output Current: 12.5A
Output Frequency: 0-400HZ
Type: AC-DC-AC
Output Voltage: 380v
Input Voltage: 380v
Weight: 3.5KG
Size: 222*126.5*168
Output Type: Triple
Output Power: 5.5kw
Model Number: JAC580A-5R5G-4-5022
Brand Name: JARCDRIVE
Place of Origin: China (Mainland)
Color: White
Communication: Modbus RS485
Display: LED
Control Method: V/F

Specifications

Item

Specification
Standard functions Maximum frequency V/F control: 0~500Hz
Carrier frequency 0.5kHz~16kHz

The carrier frequency is automatically 

adjusted based on the load features.

Input frequency Digital setting: 0.01Hz
Analog setting: maximum frequency x 0.025%
Control mode ? Voltage/Frequency (V/F) control
Basic functions                Speed range 1:50  (VF)
Overload capacity 60s for 150% of the rated current, 3s for 180% of the rated current
Torque boost ?Fixed boost
? Customized boost 0.1%–30.0%
V/F curve ? Straight-line V/F curve
? Multi-point V/F curve

?N-power V/F curve (1.2-power, 1.4-power, 

1.6-power, ,1.8-power, square)

V/F separation Two types: complete separation; half separation
Acceleration deceleration curve ?Straight-line ramp
? S-curve ramp

Four groups of acceleration/deceleration time 

with the range of 0.0–6500.0s

DC braking. DC braking frequency: 0.00Hz~maximum frequency
Braking time: 0.0s~36.0s
Braking action current value: 0.0%–100.0%
JOG control JOG frequency range: 0.00–50.00 Hz
JOG acceleration/deceleration time: 0.0–6500.0s
Simple PLC and

It implements up to 16 speeds via the simple PLC function 

or combination of DI terminal states.

multi-speed operation
Onboard PID It realizes process-controlled closed loop control system easily.
Automatic voltage

It can keep constant output voltage automatically

when the mains voltage changes.

regulation (AVR)

Overvoltage

Overcurrent stall control

The current and voltage are limited automatically 

during the running process so as to avoid 

frequent tripping due to overvoltage/overcurrent.

Quick current limiting

Maximize overcurrent failure and 

protect the frequency converter in normal operation

Torque limit and control

It can limit the torque automatically and prevent frequent 

over current tripping during the running process.          

Torque control can be implemented in the CLVC mode.

Bus support Support field bus: Modbus, to realize system integration
Individualized functions

Electrify peripheral 

equipment self-check

to electrify and to do the security detection of peripheral equipment
Sharing DC bus fuction to realize several frequency inverters sharing the DC bus
Timing control Time range: 0.0–65535.0 minutes

Spinning Oscillating

frequency

multi-triangular frequency control function
Operation Command source

Operation panel, control terminal and serial 

communication port are given

Switch in various methods
Frequency source

Various frequency sources: digital reference, analog voltage 

reference, analog current reference, pulse reference and 

serial port reference. The switching can be conducted

 in various methods

Auxiliary frequency source

10 kinds of auxiliary frequency source.

The auxiliary frequency jog and frequency 

synthesis can be achieved flexibly

 Input terminal 5 digital input terminals, compatible active PNP or NPN input mode

2 analog input terminals, among which one only supports voltage 

input and the other supports voltage input

Output terminal 1 digital output terminal
1 relay output terminal

1 analog output terminal, supporting current outpout 

of 0~20mA or voltage output of 0~10V

Display and 

keyboard operation

LED display Display the parameter

Key lock and 

function selection

Realize partial or all key lock and define the action range 

of some keys to prevent misoperation

Protection function

Short circuit test of electrified motor, input/output default 

phase protection, overcurrent protection, overvoltage protection, 

undervoltage protection, overheat protection, overload protection, etc.

Options

IO expansion card, differential input PG card, 

OC input PG card and rotary transformer PG card.

Environment Service site

Indoor, free from direct sunshine, no dust, corrosive gas, 

combustible gas, oil fog, water vapor, drip or salt, etc.

Altitude Less than 1,000m
Ambient temperature

-10℃~ +40℃ (Please use the equipment by 

derating at ambient temperature of 40℃~50 ℃)

Humidity Less than 95%RH, no water condensation
Vibration Less than 5.9m/s2(0.6g)
Storage temperature -20℃~ +60℃