Output Current: | 12.5A |
---|---|
Output Frequency: | 0-400HZ |
Type: | AC-DC-AC |
Output Voltage: | 380v |
Input Voltage: | 380v |
Weight: | 3.5KG |
Size: | 222*126.5*168 |
Output Type: | Triple |
Output Power: | 5.5kw |
Model Number: | JAC580A-5R5G-4-5022 |
Brand Name: | JARCDRIVE |
Place of Origin: | China (Mainland) |
Color: | White |
Communication: | Modbus RS485 |
Display: | LED |
Control Method: | V/F |
Quick Details
Specifications
Item |
Specification | ||
Standard functions | Maximum frequency | V/F control: 0~500Hz | |
Carrier frequency | 0.5kHz~16kHz | ||
The carrier frequency is automatically adjusted based on the load features. |
|||
Input frequency | Digital setting: 0.01Hz | ||
Analog setting: maximum frequency x 0.025% | |||
Control mode | ? Voltage/Frequency (V/F) control | ||
Basic functions | Speed range | 1:50 (VF) | |
Overload capacity | 60s for 150% of the rated current, 3s for 180% of the rated current | ||
Torque boost | ?Fixed boost | ||
? Customized boost 0.1%–30.0% | |||
V/F curve | ? Straight-line V/F curve | ||
? Multi-point V/F curve | |||
?N-power V/F curve (1.2-power, 1.4-power, 1.6-power, ,1.8-power, square) |
|||
V/F separation | Two types: complete separation; half separation | ||
Acceleration deceleration curve | ?Straight-line ramp | ||
? S-curve ramp | |||
Four groups of acceleration/deceleration time with the range of 0.0–6500.0s |
|||
DC braking. | DC braking frequency: 0.00Hz~maximum frequency | ||
Braking time: 0.0s~36.0s | |||
Braking action current value: 0.0%–100.0% | |||
JOG control | JOG frequency range: 0.00–50.00 Hz | ||
JOG acceleration/deceleration time: 0.0–6500.0s | |||
Simple PLC and |
It implements up to 16 speeds via the simple PLC function or combination of DI terminal states. |
||
multi-speed operation | |||
Onboard PID | It realizes process-controlled closed loop control system easily. | ||
Automatic voltage |
It can keep constant output voltage automatically when the mains voltage changes. |
||
regulation (AVR) | |||
Overvoltage Overcurrent stall control |
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/overcurrent. |
||
Quick current limiting |
Maximize overcurrent failure and protect the frequency converter in normal operation |
||
Torque limit and control |
It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be implemented in the CLVC mode. |
||
Bus support | Support field bus: Modbus, to realize system integration | ||
Individualized functions |
Electrify peripheral equipment self-check |
to electrify and to do the security detection of peripheral equipment | |
Sharing DC bus fuction | to realize several frequency inverters sharing the DC bus | ||
Timing control | Time range: 0.0–65535.0 minutes | ||
Spinning Oscillating frequency |
multi-triangular frequency control function | ||
Operation | Command source |
Operation panel, control terminal and serial communication port are given |
|
Switch in various methods | |||
Frequency source |
Various frequency sources: digital reference, analog voltage reference, analog current reference, pulse reference and serial port reference. The switching can be conducted in various methods |
||
Auxiliary frequency source |
10 kinds of auxiliary frequency source. The auxiliary frequency jog and frequency synthesis can be achieved flexibly |
||
Input terminal | 5 digital input terminals, compatible active PNP or NPN input mode | ||
2 analog input terminals, among which one only supports voltage input and the other supports voltage input |
|||
Output terminal | 1 digital output terminal | ||
1 relay output terminal | |||
1 analog output terminal, supporting current outpout of 0~20mA or voltage output of 0~10V |
|||
Display and keyboard operation |
LED display | Display the parameter | |
Key lock and function selection |
Realize partial or all key lock and define the action range of some keys to prevent misoperation |
||
Protection function |
Short circuit test of electrified motor, input/output default phase protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection, etc. |
||
Options |
IO expansion card, differential input PG card, OC input PG card and rotary transformer PG card. |
||
Environment | Service site |
Indoor, free from direct sunshine, no dust, corrosive gas, combustible gas, oil fog, water vapor, drip or salt, etc. |
|
Altitude | Less than 1,000m | ||
Ambient temperature |
-10℃~ +40℃ (Please use the equipment by derating at ambient temperature of 40℃~50 ℃) |
||
Humidity | Less than 95%RH, no water condensation | ||
Vibration | Less than 5.9m/s2(0.6g) | ||
Storage temperature | -20℃~ +60℃ |