Product Main

Quick Details

Type: Spray Booths
Model Number: TG-60B
Brand Name: TARGET
Place of Origin: China (Mainland)
Voltage: 220/380V/415v
Internal Size: 6900*4000*2800 (LxWxH)
External Size: 7000*5400*3450 (LxWxH)
Power: 16KW

Specifications

Photoes:
Car spray painting booth TG60B

Car spray painting booth TG60B

Transporation for Export:
Spray Booth Paint Room Machine
Spray Booth Paint Room Machine
Specifiactions:


60B

Inside dimension

Front door(mm)

3000*2700 mm(W×H)

Outside dimension

7000*5400*3450 (LxWxH)

Total Power(Kw)

16 Kw,

Wallboard

EPS (epispastics polystyrene) colorful steel skin panel,EPS foam Density is 16kg/m3,50mm thick, steel 0.5mm thick,Compound construction, anti-flame and heat-insulation, galvanized steel roof panel.

Basement

350mm depth, Galvanized steel sheet and square steel pipe assembling, 2 rows of grid plates made by flat bar and round steel, 3 rows of diamond plates, galvanized.2 ramps, external setting, 750 x 2000 mm ( W * L )/PC

Air Circulation System

Intake Fan

3/h

Exhaust Fan

Blower Capacity:15000m3/h

Power:5.5kw/PC

Quantity:2 pcs

Quantity:1 PC

Model: Double-intake centrifugal fan

Air Volume: 25000m3/h,Air flow speed in the cabin: 0.25m/s

Heating system

Burner

Italy Riello G20 Diesel Burner, 200000Kcal/h.SUS304Stainless steel heat exchanger, argon arc welding.

Heat energy

Max Temp: 80. C, Heating Time: 4-5min(20-60°C), Fuel Consumption: 4-5kg/vehicle

Filter system

Dual-filtering structure

Primary filter:Can Capture Granules Larger than 10μm

Ceiling filter: 600g high efficiency filter,Can Capture Granules Bigger than 4μm

Floor filter: fiberglass filter, exhaust activated carbon filter, Filtering rate> 95%

Lighting system

Ceiling lights

8Units×4Pcs=32Pcs×36W

Side lights

6Units×4Pcs=24Pcs×30W900LUX, with anti-explosion design.

Control system

Spraying, heat spraying, time setting, lighting switch, failure indicator, thermostat, power supply switch, emergency stop. All motors are full voltage start.

Environmental System

Multi-Layer Fiberglasses Filter, active-carbon, and ensure a qualified exhaust according to the relevant state standards