Product Main

Quick Details

Model Number: vg 091A
Brand Name: FIZOPTIKA
Place of Origin: Russian Federation

Specifications

 

VG 091A is the smallest ever  fiber optic gyroscope system (sensing optics and electronics in one housing)

Most sensitive and accurate in its size

Recently developed plastic frame is expected to bring to the VG 091A  even lower 30g weight and better bias behavior
Just +5V for full system performance

Lowest 0.5 W  power

Fastest 0.02 s start-up
Widest 1kHz    bandwidth

Lowest 30 gram weight

 

PHYSICAL PARAMETERS

1.

Ω- sensing axis

2.

Dissipation - 1 W

3.

Weight - 30 gram ( 40 gram max )

4.

Volume - 0.025 litre

5,

Housing material - aluminum alloy

6.

Housing protection - anodizing

7.

Tolerances per ISO 2768-m

8.

Ingress protection class - IP67

 

Specification

MAIN PARAMETERS ( typical values )

?  Rate range                                    300 deg/s

   Scale Factor (SF)                          7 mV/deg/s

   Frequency range                            0... 1 kHz

   Angle random walk                       0.04 deg /√h

   Bias stability, RMS                       4 deg/h 

   SF stability, RMS                          0.1 %

   Readiness time                               0.02 s 

ENVIRONMENT

Temperature operating                     -40°C ... +70°C

Temperature endurance, 2 hr           -55°C... +85°C

Vibration, RMS                                12g, 20Hz...2kHz

Shocks                                              150g, 1 ms

Acceleration                                      5g

  ?? RELIABILITY

MTBF                                              60000 hours (20o С, predicted)

Lifetime (predicted)                         15 years

  ? Precision class - 4

?? Estimated for low humidity


RECOMMENDATIONS AND PRECAUTIONS

 

1.

Do not deform housing

2.

Fragile components inside - no shocks, no drop

3.

Treat as electrostatic sensitive unit

4.

Is designed to be mounted inside water protected equipment

5.

Increased humidity shortens essentially lifetime

6.

Mounting surface must be grounded

7.

Power must be off during connecting

8.

Soldering to contacts - by low-temperature solder