Specifications

 

Fiber optic gyroscope VG103PT - is modified VG949P with embedded TMP36 - sensor of internal temperature.
Via additional contact it provides possibility for better modelling and data correction.

Due to the plastichousing the gyro interior is well isolated from variable ambient.
Upgraded assembling brings to the gyro better shock endurance

 

 PHYSICAL PARAMETERS

1.

Ω - sensing axis, 90°± 1° to the reference plane

2.

Dissipation - 1 W

3.

Weight - 55 gram ( 80 gram max )

4.

Volume - 0.07 litre

5.

Housing material - plastic

6.

Tolerances per ISO 2768-m

7.

Ingress protection class - IP67


Specification

MAIN PARAMETERS ( typical values )

?  Rate range                              300 deg/s

   Scale Factor (SF)                    6 mV/deg/s

   Frequency range                     0... 1 kHz

   Angle random walk                0.02 deg /√ h

   Bias stability, RMS                3 deg/h 

   SF stability, RMS                  0.1 %

   Readiness time                       0.02 s 


 
ENVIRONMENT

  ??? Temperature operating                 -40°C ... +70°C

???? Temperature endurance                -55°C... +85°C

         Vibration, RMS                             18g, 20Hz...2kHz

         Shocks                                           350g, 1 ms

         Acceleration                                  5g

 

  ?? RELIABILITY

 MTBF                                        60000 hours (20° С, predicted)

 Lifetime (predicted)                   15 years

   

? Precision class - 4 

   ?? Estimated for low humidity

 ??? Operating temperature - temperature of built-in temperature sensor 

???? Endurance temperature - environment temperature. Sensor is turned off.

RECOMMENDATIONS AND PRECAUTIONS

1.

Do not deform housing

2.

Fragile components inside - no shocks, no drop

3.

It is recommended to use 2 diagonal screws with elastic washers for mounting

4.

Treat as electrostatic sensitive unit

5.

Is designed to be mounted inside water protected equipment

6.

Increased humidity shortens essentially lifetime

7.

Power must be off during connecting

8.

Soldering to contacts - by low-temperature solder