Product Main

Quick Details

Output Current: 253A
Output Frequency: 0-400HZ
Type: AC-DC-AC
Output Voltage: 380V
Input Voltage: 380V
Weight: 135KG
Size: 970*579*380mm
Output Type: Triple
Output Power: 132KW
Model Number: JAC580-132G-4-5070A
Brand Name: JRACDRIVE
Place of Origin: China (Mainland)
Color: Grey
Structure: Metal
Carrier Frequency: 0.5khz-16khz
Start Torque: 0.5hz/150%;0hz/180%

Specifications

Item

Specification

Standard functions

Maximum frequency

Vector control: 0~300Hz; V/F control: 0~3200Hz

Carrier frequency

0.5kHz~16kHz

The carrier frequency is automatically adjusted based on the load features.

Input frequency resolution

Digital setting: 0.01Hz

Analog setting: maximum frequency x 0.025%

Control mode

? Sensorless flux vector control (SFVC)

? Closed-loop vector control (CLVC)

? Voltage/Frequency (V/F) control

Starting torque

? G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC)

? P type: 0.5 Hz/100%

Basic functions

Speed range

1:100  (SFVC) 1:1000  (CLVC)

Constant-speed accuracy

± 0.5%  (SFVC)

± 0.02%  (CLVC)

Torque control accuracy.

± 5%  (CLVC)

Overload capacity

? G type: 60s for 150% of the rated current, 3s for 180% of the rated current

? P type: 60s for 120% of the rated current, 3s for 150% of the rated current

Torque boost

?Fixed boost

? Customized boost 0.1%–30.0%

V/F curve

? Straight-line V/F curve

? Multi-point V/F curve

?N-power V/F curve (1.2-power, 1.4-power, 1.6-power, ,1.8-power, square)

V/F separation

Two types: complete separation; half separation

Acceleration /deceleration curve

?Straight-line ramp

? S-curve ramp

Four groups of acceleration/deceleration time with the range of 0.0–6500.0s

DC braking.

DC braking frequency: 0.00Hz~maximum frequency

Braking time: 0.0s~36.0s

Braking action current value: 0.0%–100.0%

JOG control

JOG frequency range: 0.00–50.00 Hz

JOG acceleration/deceleration time: 0.0–6500.0s

Simple PLC and

multi-speed operation

It implements up to 16 speeds via the simple PLC function or combination of DI terminal states.

Onboard PID

It realizes process-controlled closed loop control system easily.

Automatic voltage

regulation (AVR)

It can keep constant output voltage automatically when the mains voltage changes.

Over voltage/

Over current stall

control

The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over voltage/over current.

Quick current limiting

Maximize overcurrent failure and protect the frequency converter in normal operation

Torque limit and

control

It can limit the torque automatically and prevent frequent over current tripping during the running process.

Torque control can be implemented in the CLVC mode.

Individualized functions

High performance

Control of asynchronous motor and synchronous motor are implemented through the high-performance current vector control technology.

Power dip ride

through

The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time.

Rapid current limit

It helps to avoid frequent over current faults of the AC drive.

Timing control

Time range: 0.0–6500.0 minutes

Multi-motor

switchover

Four motors can be switched over via four groups of motor parameters.

Bus support

Support field bus: Modbus

Motor overheat

protection

The optional I/O extension card enables AI3 to receive the motor temperature sensor input (PT100, PT1000) so as to realize motor overheat protection.

Multiple encoder

types

Support difference, open collector and rotary transformer

Operation

Command source

Operation panel, control terminal and serial communication port are given

Switch in various methods

Frequency source

Various frequency sources: digital reference, analog voltage reference, analog current reference, pulse reference and serial port reference. The switching can be conducted in various methods

Auxiliary frequency source

10 kinds of auxiliary frequency source. The auxiliary frequency jog and frequency synthesis can be achieved flexibly

Input terminal

Standards:

7 digital input terminals, among which one support maximum high-speed pulse input of 100kHz

2 analog input terminals, among which one only supports voltage input of 0 ~10V and the other supports voltage input of 0 ~10V or current input of 4 ~20mA

Expansion capability:

3 digital input terminals

1 analog input terminal, which supports voltage input of -10V ~10V and supports PT100/PT1000

Operation

Output terminal

Standards:

1 high-speed pulse output terminal (The open collector type is optional), supporting 0~100kHz square signal output

1 digital output terminal

1 relay output terminal

1 analog output terminal, supporting current output of 0~20mA or voltage output of 0~10V

Expansion capability:

1 digital output terminal

1 relay output terminal

1 analog output terminal, supporting current output of 0~20mA or voltage output of 0~10V

Display and keyboard operation

LED display

Display the parameter

Key lock and function selection

Realize partial or all key lock and define the action range of some keys to prevent misoperation

Protection function

Short circuit test of electrified motor, input/output default phase protection, over current protection, over voltage protection, under voltage protection, overheat protection, overload protection, etc.

Options

IO expansion card, differential input PG card, OC input PG card and rotary transformer PG card.

Service site

Indoor, free from direct sunshine, no dust, corrosive gas, combustible gas, oil fog, water vapor, drip or salt, etc.

Altitude

Less than 1,000m

Ambient temperature

-10~ +40 (Please use the equipment by derating at ambient temperature of 40~50 )

Humidity

Less than 95%RH, no water condensation

Vibration

Less than 5.9m/s2(0.6g)

Storage temperature

-20℃~ +60℃

IP grade

IP20

Pollution level

PD2

Power distribution system

TN , TT