Output Current: | 426A |
---|---|
Output Frequency: | 0-400HZ |
Type: | AC-DC-AC |
Output Voltage: | 380V |
Input Voltage: | 380V |
Weight: | 208KG |
Size: | 1060*650*380mm |
Output Type: | Triple |
Output Power: | 220KW |
Model Number: | JAC580-200G-4-5080A |
Brand Name: | JRACDRIVE |
Place of Origin: | China (Mainland) |
Color: | Grey |
Structure: | Metal |
Quick Details
Specifications
Item |
Specification |
|
Standard functions |
Maximum frequency |
Vector control: 0~300Hz; V/F control: 0~3200Hz |
Carrier frequency |
0.5kHz~16kHz The carrier frequency is automatically adjusted based on the load features. |
|
Input frequency resolution |
Digital setting: 0.01Hz Analog setting: maximum frequency x 0.025% |
|
Control mode |
? Sensorless flux vector control (SFVC) ? Closed-loop vector control (CLVC) ? Voltage/Frequency (V/F) control |
|
Starting torque |
? G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC) ? P type: 0.5 Hz/100% |
|
Basic functions |
Speed range |
1:100 (SFVC) 1:1000 (CLVC) |
Constant-speed accuracy |
± 0.5% (SFVC) ± 0.02% (CLVC) |
|
Torque control accuracy. |
± 5% (CLVC) |
|
Overload capacity |
? G type: 60s for 150% of the rated current, 3s for 180% of the rated current ? P type: 60s for 120% of the rated current, 3s for 150% of the rated current |
|
Torque boost |
?Fixed boost ? Customized boost 0.1%–30.0% |
|
V/F curve |
? Straight-line V/F curve ? Multi-point V/F curve ?N-power V/F curve (1.2-power, 1.4-power, 1.6-power, ,1.8-power, square) |
|
V/F separation |
Two types: complete separation; half separation |
|
Acceleration /deceleration curve |
?Straight-line ramp ? S-curve ramp Four groups of acceleration/deceleration time with the range of 0.0–6500.0s |
|
DC braking. |
DC braking frequency: 0.00Hz~maximum frequency Braking time: 0.0s~36.0s Braking action current value: 0.0%–100.0% |
|
JOG control |
JOG frequency range: 0.00–50.00 Hz JOG acceleration/deceleration time: 0.0–6500.0s |
|
Simple PLC and multi-speed operation |
It implements up to 16 speeds via the simple PLC function or combination of DI terminal states. |
|
Onboard PID |
It realizes process-controlled closed loop control system easily. |
|
Automatic voltage regulation (AVR) |
It can keep constant output voltage automatically when the mains voltage changes. |
|
Over voltage/ Over current stall control |
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over voltage/over current. |
|
Quick current limiting |
Maximize overcurrent failure and protect the frequency converter in normal operation |
|
Torque limit and control |
It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be implemented in the CLVC mode. |
|
Individualized functions |
High performance |
Control of asynchronous motor and synchronous motor are implemented through the high-performance current vector control technology. |
Power dip ride through |
The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time. |
|
Rapid current limit |
It helps to avoid frequent over current faults of the AC drive. |
|
Timing control |
Time range: 0.0–6500.0 minutes |
|
Multi-motor switchover |
Four motors can be switched over via four groups of motor parameters. |
|
Bus support |
Support field bus: Modbus |
|
Motor overheat protection |
The optional I/O extension card enables AI3 to receive the motor temperature sensor input (PT100, PT1000) so as to realize motor overheat protection. |
|
Multiple encoder types |
Support difference, open collector and rotary transformer |
|
Operation |
Command source |
Operation panel, control terminal and serial communication port are given Switch in various methods |
Frequency source |
Various frequency sources: digital reference, analog voltage reference, analog current reference, pulse reference and serial port reference. The switching can be conducted in various methods |
|
Auxiliary frequency source |
10 kinds of auxiliary frequency source. The auxiliary frequency jog and frequency synthesis can be achieved flexibly |
|
Input terminal |
Standards: 7 digital input terminals, among which one support maximum high-speed pulse input of 100kHz 2 analog input terminals, among which one only supports voltage input of 0 ~10V and the other supports voltage input of 0 ~10V or current input of 4 ~20mA Expansion capability: 3 digital input terminals 1 analog input terminal, which supports voltage input of -10V ~10V and supports PT100/PT1000 |
|
Operation |
Output terminal |
Standards: 1 high-speed pulse output terminal (The open collector type is optional), supporting 0~100kHz square signal output 1 digital output terminal 1 relay output terminal 1 analog output terminal, supporting current output of 0~20mA or voltage output of 0~10V Expansion capability: 1 digital output terminal 1 relay output terminal 1 analog output terminal, supporting current output of 0~20mA or voltage output of 0~10V |
Display and keyboard operation |
LED display |
Display the parameter |
Key lock and function selection |
Realize partial or all key lock and define the action range of some keys to prevent misoperation |
|
Protection function |
Short circuit test of electrified motor, input/output default phase protection, over current protection, over voltage protection, under voltage protection, overheat protection, overload protection, etc. |
|
Options |
IO expansion card, differential input PG card, OC input PG card and rotary transformer PG card. |
|
Service site |
Indoor, free from direct sunshine, no dust, corrosive gas, combustible gas, oil fog, water vapor, drip or salt, etc. |
|
Altitude |
Less than 1,000m |
|
Ambient temperature |
-10℃~ +40℃ (Please use the equipment by derating at ambient temperature of 40℃~50 ℃) |
|
Humidity |
Less than 95%RH, no water condensation |
|
Vibration |
Less than 5.9m/s2(0.6g) |
|
Storage temperature |
-20℃~ +60℃ |
|
IP grade |
IP20 |
|
Pollution level |
PD2 |
|
Power distribution system |
TN , TT |