Usage: | Auto Testing Machine |
---|---|
Power: | Electronic |
Brand Name: | SYSTESTER |
Warranty: | 1 |
weight: | 54 |
Model Number: | GTR |
Place of Origin: | China (Mainland) |
Temperature accuracy: | 0.1 |
Temperature range: | 5~95 |
Quick Details
Specifications
Battery Separation Charge and Discharge Performence Testing Equipment Air Permeability Tester
Product Detail
Application:
GTR is based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Battery Separation Charge and Discharge Performence Testing Equipment Air Permeability Tester
Features:
Vacuum differential pressure method
Patent technology
3 specimens test simultaneously and independently
Computer control
One-button test, test automatically through whole process
High accuracy vacuum sensors embedded in
3 Chambers with independent temperature sensor
Test under various RH conditions with Humidity generator (optional)
Environment temperature and humidity sensor inside
Permeability coefficient,solubility coefficient and diffusion coefficient test
Chambers with water bath temperature control technology
Unit based on embedded system,24bit - AD
Multiple test modes optional
Data curves display
Traceable reference film calibration
Supports DSM system (DSM, lab data management system)
Battery Separation Charge and Discharge Performence Testing Equipment Air Permeability Tester
Technical Indexes:
Test range | 0.01 - 190,000 cm3/m224h0.1MPa (Standard) |
Resolution | 0.001cm3/m224h0.1MPa |
Samples | 3, independent |
Vacuum accuracy | 0.1Pa |
Temperature range | 5C - 95C |
Temperature accuracy | 0.1C |
Humidity range | 0%RH,35%RH-90%RH,100%RH (optional) |
Humidity accuracy | 1%RH (optional) |
Sample thickness | less 5mm |
Sample size | >= 150mm * 94mm |
Test area | 48cm2 |
Test gas | O2, N2, CO2, He, etc |
Differential pressure | -0.1MPa - 0.1MPa |
Gas interface |
8mm |
Dimension | 730mm * 510mm * 350mm |
Power supply | AC 220V 50Hz |
Net wt. | 63kg |