Product Main

Quick Details

Usage: alititude simulation
Power: Electronic
Model Number: BE- 8104
Brand Name: DGBELL
Place of Origin: China (Mainland)

Specifications

Application  

Battery low pressure (high attitude) simulation test, all the testing specimen are being tested under 11.6kPa (1.68psi)

Purposes

To judge the test result on condition of no explosion, flame, smoke, electric leakage after test. And the battery protection valve should not be broken. 

Standard Compliance

UN 38.3,

UL 1642,

IEC61960,

IEC62133,

GB31241 testing standards 

Structure

Chamber adopt high quality cold rolled steel plate, surface with powder painted, with strong anti-rust ability.

Working room with high quality stainless steel plate, rounded shape, smooth, and easy for cleaning.

Between working room and chamber, filled with superfine glass fiber insulation material . 

Chamber door with double toughened glass structure, available for clear observation of the inside chamber.

Installed rubber sealing ring between working room and glass door, ensure high vacuum rate inside the chamber.

Integrated type : low pressure chamber on upper side, and vacuum pump on bottom side.

Technical Parameters  

Temp. Range

Ambient Temperature

Display Method

Digital Display

Unit

Kpa

Internal Dimension

W600 X D600 X H600mm

Internal Material

SUS 304# Stainless Steel (thickness 6.0mm)

External Dimension

W940 X D780 X H1620mm

External Material

SECC steel plate ,power painted (thickness 1.5mm)

Bottom

Installed with universal wheel

Observation Window

Toughened glass with explosion - proof membrane

Timer

4 digits display 0~9999(Hour, Minutes, Seconds changeable)

Vacuum Rate

Safety Devices

1.3Kpa(standard requires 11.6Kpa,vacuum gauge indication value -89.7Kpa)

Remarks:as the inner chamber pressure is(101.325Kpa), if wants the inner chamber pressure decreased to 11.6Kpa. Calculating according to atmosphere pressure of(101.325Kpa), need to blow out (89.7Kpa) pressure of the inside chamber, then the inner chamber can reach low pressure environment of (11.6Kpa).

Pressure

0~100Kpa(Controllable, display)

Pressure Fluctuation

≤5%

Power Source

AC 220V 50HZ

Power

2.0KW

Notices

When transportation, please with no force on the glass, and no shock on chamber body. The machine shall be placed on flat floor. 
No use under environment of direct sunshine or high temperature & moisture place.

Away from strong electromagnetic interference, and machine with well grounding.

When normal running, the specimen shall not touch the inner chamber wall.

Power wire not abut on back side, and do not let the machine or other objects press on it, avoid wire broken.