Product Main

Quick Details

Model Number: PHT-6000
Brand Name: Phase II
Place of Origin: China (Mainland)

Specifications

Features:
  • Non-Destructive hand held portable hardness tester
  • Combines UCI and Leeb portable hardness testing in one state of the art device
  • Test steel with min thickness of . 08" and unlimited max thickness (Other materials may have larger minimum thickness levels, depending on hardness)
  • Blazing fast test results
  • Rockwell, Brinell and Vickers hardness test conversions shown on display
  • Large Memory w/USB Output
  • Choice of manual UCI probes; 1kg, 2kg, 5kg & 10kg
  • Optional Motorized Probes: . 30kg, . 80kg, & 1kgf
  • Available Impact Devices(Leeb) D, DC, D+15, G & DL
  • MEASURING METHOD: UCI & Leeb Portable Hardness Testers

    There are two basic methods of portable hardness testing that is accepted in the field today.

    " Ultrasonic Contact Impedance" is based on a 136 degree diamond at the end of a vibrating rod being depressed into the test surface at a fixed load. The difference in Ultrasonic vibration frequency is then calculated into a hardness value. The UCI portable hardness tester procedure is slower than the Dynamic Impact style, however the " UCI" method of hardness testing is portable, easy and accurate. It also has its own advantages when utilized for certain testing applications. UCI portable hardness testers are not restricted to large mass items like dynamic type testers. These portable hardness testers can test metals as thin as 2mm and at a hardness value as low as 20HRC (75HB). They also excel at performing hardness tests on larger, harder metals as well. Another reason for the rise in popularity is due to the fact that the UCI method is categorized as " Non-Destructive" . That translates into less scrap parts/ lower mfg costs due to necessary inspections.

    " Dynamic Impact" is based on the Leeb principle of portable hardness, developed by Dietmar Leeb in the 1970's. A spring loaded impact body is thrust to the test surface, effecting rebound. The speed of both the initial thrust and the rebound is measured in a non-contact mode. This is calculated as a Leeb hardness value and then automatically converted to Rockwell C, B, Brinell, Vickers and Shore Values. It has effectually brought easy, fast and accurate results to portable hardness testing.

    UCI Portable Hardness testers
    Scales-UCI Measurement Range Tolerance
    Rockwell C
    Rockwell B
    20-70 HRC
    41-99 HRB
    +/- 1.5 HRC
    +/-1.5 HRB
    Rockwell A 61-85 HRB +/-1.5 HRA
    Brinell
    Vickers
    76-618 HB
    80-1599 HV
    +/- 3% HB
    +/- 3% HV

    Can also test in the following scales(UCI only) HRN15 - HRN30 - HRN45 - HRT15 - HRT30 - HRT45 HRF – HK - HD

    LEEB Portable Hardness Testers
    Scales-UCI Measurement Range Tolerance
    Rockwell C
    Rockwell B
    25-67 HRC
    59-99 HRB
    +/- 1.5 HRC
    +/-1.5 HRB
    Brinell 85-651 HB +/- 10 HB
    Vickers
    Shore
    83-976 HV
    26-99HS
    +/- 12 HV
    +/-10HS
    Leeb 170-960HLD +/- 6HL
    UCI portable hardness tester w/manual probe
    Model No. Description Application Notes
    PHT-6001 UCI Portable Hardness Tester w/1kgf Probe For surfaces with Ra below 125μin
    PHT-6002 UCI Portable Hardness Tester w/2kgf Probe For surfaces with Ra below 200μin
    PHT-6005 UCI Portable Hardness Tester w/5kgf Probe For surfaces with Ra below 400μin
    PHT-6010 UCI Portable Hardness Tester w/10kgf Probe For surfaces with Ra below 600μin
    UCI portable hardness tester w/motorized probe
    Model No. Description Application Notes
    PHT-6030 UCI Portable Hardness Tester w/. 30kgf Probe Best for checking coating layer hardness; Finished thin parts
    PHT-6080 UCI Portable Hardness Tester w/. 80kgf Probe Best for smooth bearing type surfaces
    PHT-6100 UCI Portable Hardness Tester w/1kgf Probe Best for machined surfaces
    Specifications:
    Hardness Range
    Scale Selection

    Tolerance

    Display Type
    HRC: 20.3- 70; HRB: 61-85.6 ; HV: 80-1599; HB: 76-618
    Rockwell C (HRC); Rockwell B (HRB); Rockwell A (HRA); Brinell (HB); Vickers (HV); Leeb (HLD) and many more!
    +/- 3.0% deviation of average from the reference value of the hardness test block with a minimum of 5 tests
    LCD Color Screen w/Backlight, adjustable brightness
    Language Selection
    Data Logger
    Data Memory
    English, German, Chinese, Spanish, etc.
    Letters, Numerals
    2000 groups of measured data ; 20 groups of calibration data
    Statistical Software
    Data Output
    Supplied-can be saved in Word or Excel
    USB – cable supplied
    Power Supply
    Auto Power Off
    Rechargeable Lithium Battery: Voltage-4.2V, 4800mAh
    5 minutes
    Recharging Time
    Battery Usage
    Approx. 8 hours
    Approx. 6 hours (no backlight)
    Net Weight(base unit)
    Gross Weight
    2lbs (w/probe)
    12 lbs
    Unit Dimensions
    Gross Dimensions
    7.0 x 3.1 x 1.1" (160x80x30mm)
    13.7 x 17.7 x 5.9" (350x450x150mm)
    Manual UCI Probe Specifications:
    Probe Type/Model PHT-6001 PHT-6002 PHT-6005 PHT-6010
    Loading Force 1kgf (10N) 2kg (20N) 5kg (50N) 10kg (98N)
    Probe Diameter
    Length
    Oscillating Rod Diameter
    22mm
    154mm
    2.4mm
    22mm
    154mm
    2.4mm
    22mm
    154mm
    3mm
    22mm
    154mm
    3mm
    Surface Roughness Requirements
    μm=Metric μin= Inch
    Ra< 3.2μm
    (Ra< 125 μin)
    Ra< 5μm
    (Ra< 197 μin)
    Ra< 10 μm
    (Ra< 393 μin)
    Ra< 15 μm
    (Ra< 590 μin)
    Min weight of test sample
    Minimum thickness of sample
    0.3kg (. 66lbs)
    2mm (. 08" )
    0.3kg (. 66lbs)
    2mm (. 08" )
    0.3kg (. 66lbs)
    2mm (. 08" )
    0.3kg (. 66lbs)
    2mm (. 08" )