Model Number: CZBT1-132
Brand Name: Tianan Electric
Place of Origin: China (Mainland)
Application: Emergency power supply
Voltage rating: High voltage

Specifications

    Service condition

1 Ambient condition

 a. Altitude ≤ 1000m;

  b. Ambient temperature

 Range of temperature: -25℃~+40℃;

  c. Wind speed (outdoor) ≤ 35m/s;

  d. Relative humidity ≤ 90%(+25℃);

  e. Installation spot

The place shall have no fire, explosion, chemical corrosion and exquisite vibration.

2 Move condition of the substation

a. Max. speed ≤ 30km/h,when road surface is flat;

b. Max. speed ≤ 10km/h, when road surface is not flat.

Note: If the above condition can't satisfy requirements, customer can consult with manufacturer to resolve it.

2.     Technical parameters

1. Rated capacity of main transformer kVA

5000,6300,8000,10000,12500,16000,20000,25000

2. Technical parameters of HV side switch equipment 2.1. Rated technical parameters of disconnector (Table 1)

Table 1

No.

Item

Unit

Parameter

1

System voltage

kV

132

2

Rated voltage

kV

145

3

Rated frequency

Hz

50

4

Rated current

A

2000,1600

5

Rated 1min power frequency withstand voltage

kV

275

6

Rated lightning impulse withstand voltage

kV

650

7

Rated short time withstand current

KA

25,31.5,40

8

Rated short time withstand time

s

3

9

Rated peak withstand current

kA

63,80,100

2.2 Rated technical parameter of circuit breaker (Table 2)

Table 2

No.

Item

Unit

Parameter

1

System voltage

kV

132

2

Rated voltage

kV

145

3

Rated frequency

Hz

50

4

Rated current

A

2000

5

Rated 1min power frequency withstand voltage

kV

275

6

Rated lightning impulse withstand voltage

kV

650

7

Rated short time withstand current / time

KA/s

40/4

8

Rated peak withstand current

kA

100

9

Rated short circuit breaking current

kA

40

10

Rated short circuit making current

kA

100

11

DC component

%

40

12

Rated operation sequence

 

O 0.3s CO 180s CO

13

Opening time

ms

35±5

14

Closing time

ms

105±15

15

Breaking time

ms

≤60

16

Non-simultaneity between poles

Closing

ms

≤5

Opening

ms

≤3

17

Fracture no. of each pole

nos

1

18

Mechanical endurance

Times

≥6000

19

Full capacity continuous breaking times

Times

≥20

20

SF6 gas pressure

(20)

Rated value

MPa

0.60

Alarm value

MPa

0.55

Locking value

MPa

0.50

21

SF6 gas moisture

content(μl/l)

Acceptance value

PPm

≤150

Operation allowable value

PPm

≤300

22

SF6 yearly gas leakage rate

%

≤0.5

23

Total weight of each circuit breaker

kg

2000

 

2.3. Parameters of current transformer (Table 3, table 4)

    Table 3

Rated primary current

150, 300, 500, 750, 1000, 1500, 2000

Rated secondary current

5A

Rated output capacity and accuracy level

 

See table 4

    Table 4

Current ratio

Rated output capacity VA

Measure accuracy level

Protection accuracy level

150/5

300/5

500/5

750/5

1000/5

1500/5

2000/5

20

20

30

30, 40

40, 50

50

50

0.5

0.5

0.5

0.5

0.5

0.5

0.5

5P20

5P20

5P20

5P20

5P20

5P20

5P20

Note: (1) Straight-through type bushing current transformer is attached in the circuit breaker. 

2.4.Parameters of lightning arrester(Table 5), parameters of neutral point lightning arrester(Table 6).

Table 5

No.

Item

Unit

Parameter

1

System voltage

kV

132

2

Rated voltage

kV

150

3

Rated frequency

Hz

50

4

Nominal discharge current

kA

10

5

DC 1mA reference voltage

kV

≥245

6

Residual voltage under lightning impulse current (peak)

kV

≤435

7

Residual voltage under operation impulse current (peak)

kV

≤370

22

Residual voltage under  steep wave impulse current (peak)

kV

≤490

Table 6

No.

Item

Unit

Parameter

1

System voltage

kV

132

2

Rated voltage

kV

90

3

Rated frequency

Hz

50

4

Nominal discharge current

kA

1.5

5

DC 1mA reference voltage

kV

≥140

6

Residual voltage under lightning impulse current (peak)

kV

≤260

7

Residual voltage under operation impulse current (peak)

kV

≤240

8

Residual voltage under  steep  wave impulse current (peak)

kV

/

 

3.Technical parameters of switch equipment on LV side(Table 7)

Table 7

No.

Item

Unit

Parameter

1

System voltage

kV

11.5

2

Rated voltage

kV

12

3

Rated frequency

Hz

50

4

Rated current

A

2000, 1600, 1250,

5

Rated 1min power frequency withstand voltage

kV

42/48

6

Rated lightning impulse withstand voltage

kV

75/85

7

Rated short time withstand current

kA

40, 31.5, 25

8

Rated short time withstand time

s

4

9

Rated peak withstand current

kA

100, 80, 63

10

Rated short circuit breaking current

kA

40, 31.5, 25

11

Rated short circuit making current

kA

100, 80, 63

12

Rated operation sequence

 

O 0.3s CO 180s CO

13

Mechanical endurance

Times

≥10000

4.Sound level of the substation: ≤65 dB

Protection grade of enclosure of switch chamber: IP23(when the door for natural ventilation is open); IP43(when the door for natural ventilation is closed)