Usage: | Auto Testing Machine |
---|---|
Power: | Electronic |
Model Number: | LRHS-108/270/412/663/816/1080-RY |
Brand Name: | LINPIN |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
Salt Spray Test Chamber Purpose
Salt spray test chamber is applicable for the salt spray corrosive test for the protected layer of components, parts, electronic and electrical parts and metal materials and industrial products.
Salt spray test chamber can be supplied in two versions the basic salt spray chamber and the cyclic corrosion test chamber CCT as applicable for the customers testing and will meet all of the most stringent test requirements.
Salt Spray Test Chamber Dimension Comparison
Volume (Unit: L) |
Dimension of Working Room (D*W*H)mm |
Overall Dimension (D*W*H)mm |
108 |
450×600×400 |
700×1200×1100 |
270 |
600×900×500 |
870×1400×1150 |
412 |
750×1100×500 |
1030×1680×1260 |
663 |
850×1300×600 |
1160×2000×1390 |
816 |
850×1600×600 |
1190×2260×1450 |
1080 |
900×2000×600 |
1220×2350×1450 |
Salt Spray Test Chamber Technical Index
1.1. Temperature range 1.2. Air saturator 1.3. Humidity range |
RT+5°C~55°C RT+10°C~70°C 85~98%RH |
1.1. Temperature uniformity 1.4. Temperature volatility |
≤2°C ±0.5°C |
1.5. Salt spray settlement 1.6. Pressure of compressed air |
1~2ml/80cm2.h 2.00±0.01(kg/cm2) |
1.7. Spraying method 1.8. Period time 1.9. Test specimen shelf |
Optional continuous/periodic test time: 1~9999 H,M,S (Adjustable) Test specimen shelf can meet the requirements of 15°C~30°C tilt test) |
1.10. Power supply requirements |
AC220V/AC380V±10% 50±0.5Hz |
Salt Spray Test Chamber Available Test Methods
1. Neutral salt spray test (NSS test)
2.Salt spray test (SS test)
3.Acetic acid salt spray test (AASS test)
4.Copper accelerated acetic acid salt spray test(CASS test)
5.High-temperature humid heat test
6.Standard configuration of test chamber
Salt Spray Test Chamber Safety Protection Equipment
1) No fuse protective switch (prevent short circuit of control circuit)
2)Overtemperature protection of chamber structure and saturator (prevent overheating of the laboratory to protect test specimens)
3)Low water level protection of chamber structure and saturator (prevent shortage of water of saturated barrel)
4)Two-stage pressure stabilizing and regulation protection of compressed air
5)Overload and leakage protection through automatic switch
6)Power leakage protection
7)Overload and short circuit protection
8)Power failure protection in case of opening of electrical control cabinet
9)Automatic shutdown upon fault alarming
Salt Spray Test Chamber Standards
Applied
GB/T2423.17; GB/T10125-1997; GB10587; GB6460; GB1771;
ASTM-B117; GJB150;DIN50021-75; ISO3768, 3769, 3770;CNS 3627, 3885, 4159, 7669
etc.