Product Main

Quick Details

Price: Best for 4-20mA Differential Pressure Transmitter Yokogawa EJA110E
Protocol: BRAIN or HART
Accuracy: 0.055%
Output range: 3.6 mA to 21.6 mA
Quality: Original
Application: For wide application testing
Output: 4 to 20 mA DC
Measuring range: 0-140bar Max

Specifications


Original 4-20mA Differential Pressure Transmitter Yokogawa EJA110E

 

The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family of pressure transmitters. Released in 2012, it combines the ruggedness and success of the work-horse EJA-A series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.

The EJA110E is our standard traditional-mount differential pressure transmitter in this series.

EJA110E features include:

  • 0.055% Accuracy (0.04% Accuracy option)
  • 0.1% Stability for 7 years
  • MWP 2,300 psi (MWP 3,600 psi option)
  • 90 ms Response Time
  • Local Parameter Setting (LPS)
  • SIL 2 (IEC 61508) Certified

 

The high performance differential pressure transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure.

EJA110E outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure.

Its accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAIN or HART communications.

Other key features include quick response, remote set-up using communications and self-diagnostics. FOUNDATION Fieldbus, PROFIBUS PA and 1 to 5 V DC with HART (Low Power) protocol types are also available.

All EJA-E series models in their standard configuration, with the exception of the Fieldbus, PROFIBUS and Low Power types, are certified as complying with SIL 2 for safety requirement.

 

 

Model Application Type Capsule Measurement Span Maximum Working Pressure
kPa inH2O MPa psi
EJA110E Differential
Pressure
Traditional-
Mounting*1
F
M
H
V
0.5 to 5
1 to 100
5 to 500
0.14 to 14 MPa
2 to 20
4 to 400
20 to 2000
20 to 2000 psi
16
16
16
16
2300
2300
2300
2300
EJA115E Flow Integral
Orifice
F
M
H
1 to 5
2 to 100
20 to 210
4 to 20
8 to 400
80 to 830
16
16
16
2300
2300
2300
EJA118E Differential
Pressure
& Liquid
Level
with 
Remote
Seals
Extended
Flush
Combination
M
H
2.5 to 100
25 to 500
10 to 400
100 to 2000
Based on Flange Rating
EJA120E Draft
Range
Traditional-
Mounting*1
E 0.1 to 1 0.4 to 4 50 kPa 7.25
EJA130E Differential
Pressure
& Liquid
Level
Traditional-
Mounting*1
M
H
1 to 100
5 to 500
4 to 400
20 to 2000
32
32
4500
4500
EJA210E Liquid
Level,
(Closed
or Open
Tank)
Flush
Extended
M
H
1 to 100
5 to 500
4 to 400
20 to 2000
Based on Flange Rating
EJA310E Absolute
(Vacuum)
Pressure*2
Traditional-
Mounting*1
L
M
A
B
0.67 to 10
1.3 to 130
0.03 to 3.5 MPa
0.14 to 16 MPa
0.2 to 2.95 inHg
0.39 to 38 inHg
4.3 to 500 psi
20 to 2300 psi
10 kPa
130 kPa
3.5
16
2.95 inHg
38 inHg
500
2300
EJA430E Gauge
Pressure
Traditional-
Mounting*1
H
A
B
5 to 500
0.03 to 3.5 MPa
0.14 to 16 MPa
20 to 2000
4.3 to 500 psi
20 to 2300 psi
500 kPa
3.5
16
2000 inH2O
500
2300
EJA438E Gauge
Pressure
with Remote
Seal
Flush A
B
0.06 to 3.5 MPa
0.46 to 16 MPa
8.6 to 500 psi
66 to 2300 psi
Based on Flange Rating
Extended A
B
0.06 to 3.5 MPa
0.46 to 7 MPa
8.6 to 500 psi
66 to 1000 psi
EJA440E High
Gauge
Traditional-
Mounting*1
C
D
5 to 32 MPa
5 to 50 MPa
720 to 4500 psi
720 to 7200 psi
32
50
4500
7200
EJA510E
EJA530E
Absolute
& Gauge
Pressure*2
Direct-
Mounting
A
B
C
D
10 to 200
0.1 to 2 MPa
0.5 to 10 MPa
5 to 50 MPa
1.45 to 29 psi
14.5 to 290 psi
72.5 to 1450 psi
720 to 7200 psi
200 kPa
2
10
50
29
290
1450
7200
*1: Traditional-Mounting is 1/4NPT or Rc1/4 process connections (1/2NPT or Rc1/2 with process adapter).