| Insulation Material: | PVC |
|---|---|
| Conductor Type: | Solid |
| Conductor Material: | Copper |
| Application: | |
| Type: | Bare |
| Brand Name: | LX |
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
| Applications |
For use primarily in residential wiring, including branch circuits for outlets, switches, etc. May be
installed in both exposed and concealed work in normally dry locations. May be installed in air
voids of masonry block or tile walls where these walls are not subject to excessive moisture or
dampness. May be installed in locations with temperatures up to 90°C, but with the
ampacity limited to that of 60°C conductors. Added Circuit: For use primarily in residential wiring
for branch circuits supplying outlets located in bedrooms and other areas. Has two separated
neutrals so one cable can be used to run two circuits when sharing of a neutral is not allowed.
| Conductors |
Solid conductors: Soft, uncoated copper per ASTM-B3
Stranded conductors: Uncoated copper per ASTM-B3 and ASTM B8
| Conductor Insulation and Jacket |
Color-coded PVC (polyvinyl chloride), rated 90°C dry with clear nylon (polyamide).
Added Circuit: Color-coded PVC rated 90°C: black, white, red and white with red stripe. Insulated
conductors also jacketed with clear nylon (polyamide).
| Grounding Conductor |
Soft, uncoated copper per ASTM-B3
| Assembly |
Two-conductor constructions have the insulated conductors laid parallel. Ground
wire is wrapped with paper and laid parallel between the insulated conductors. The
entire construction is wrapped with a paper separator before applying the jacket. Three
-conductor constructions have the insulated conductors twisted together or laid parallel to each
other. Ground wire is wrapped with paper and twisted together or laid parallel to the insulated
conductor.
| Jacket |
30 mil-thick PVC (polyvinyl chloride) jacket applied over the complete assembly
14-2, 14-2-2 & 14-3 w/ground: white
12-2, 12-2-2 & 12-3 w/ground: yellow
10-2 & 10-3 w/ground: orange
8 AWG or larger: black
| Industry Standards |
UL 83 File # E15119
UL 719 Non-Metallic Sheathed Cable File #E9810
ASTM-B3
ASTM-B8
Fed. Spec. A-A-59544
NFPA70: NEC?
RoHS Compliant
*It is the sole responsibility of the end user to determine suitability of this product for its intended end use and application.
| Package |
COMPANY NAME: LX WIRE AND CABLE (SUBSIDIARY OF TRUST GROUP)
YEAR FOUNDED: 1996
OCCUPIED AREA: 43000m2
NUMBER OF STUFFS: 458
ANNUAL SALES: RMB 1 BILLION
OUR FACTORY
OUR QUALITY CONTROL LABORATORY
(Equipments)
OUR GUARANTEE
When choosing cables, several issues to be considered are as below:
1,Working voltage, determining the thickness of the insulation;
2,Current-carrying capacity, determining the cross-sectional size of the conductor(s);
3,Environmental conditions such as temperature, water, chemical or sunlight exposure, and mechanical impact, determining the form and composition of the outer cable jacket.