Application: | High Voltage |
---|---|
Material: | Porcelain |
Type: | Insulator |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
ANSI ceramic line post Insulators
1. ANSI 57-1, 57-2… series ceramic line post insulators drawings, technical data and images show as follows:
Type | ||||||||
Fig NO. | 1 | 2 | 3 | 4 | 5 | 5 | ||
Leakage distance | mm | 356 | 559 | 737 | 1016 | 1143 | 1346 | |
Dry arcing distance | mm | 165 | 241 | 311 | 368 | 438 | 489 | |
Cantilever strength | kN | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 | |
Power frequency flashover voltage | Dry | KV | 70 | 100 | 125 | 140 | 160 | 180 |
Wet | KV | 50 | 70 | 95 | 110 | 130 | 150 | |
Critical impulse flashover voltage | Positive | KV | 120 | 160 | 200 | 230 | 265 | 300 |
Negative | KV | 155 | 205 | 260 | 340 | 380 | ||
Radio interference voltage | Test voltage to ground | KV | 15 | 22 | 30 | 44 | 44 | 44 |
Max. RIV at 1 MHz | μV | 100 | 100 | 200 | 200 | 200 | 200 |
2. ANSI 57-12, 57-13… series ceramic line post insulators drawings, technical data and images show as follows:
Type | ||||||||
Fig NO. | 1 | 2 | 3 | 4 | 5 | 5 | ||
Creepage distance | mm | 356 | 559 | 737 | 1016 | 1143 | 1346 | |
Dry arcing distance | mm | 165 | 241 | 311 | 368 | 438 | 489 | |
Cantilever strength | KN | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 | |
Power frequency flashover voltage | Dry | KV | 70 | 100 | 125 | 140 | 160 | 180 |
Wet | KV | 50 | 70 | 95 | 110 | 130 | 150 | |
Critical impulse flashover voltage | Positive | KV | 120 | 160 | 200 | 230 | 265 | 300 |
Negative | KV | 155 | 205 | 260 | 340 | 380 | ||
Radio interference voltage | Test voltage to ground | KV | 15 | 22 | 30 | 44 | 44 | 44 |
Max. RIV at 1 MHz | μV | 100 | 100 | 200 | 200 | 200 | 200 |
3. ANSI 57-21, 57-22… series ceramic line post insulators drawings, technical data and images show as follows:
Type | ||||||||
Fig No. | 1 | 2 | 3 | 4 | 5 | 5 | ||
Creepage distance | mm | 356 | 559 | 737 | 1016 | 1143 | 1346 | |
Dry arcing distance | mm | 165 | 241 | 311 | 368 | 438 | 489 | |
Cantilever strength | KN | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 | |
Power frequency flashover voltage | Dry | KV | 70 | 100 | 125 | 140 | 160 | 180 |
Wet | KV | 50 | 70 | 95 | 110 | 130 | 150 | |
Critical impulse flashover voltage | Positive | KV | 120 | 160 | 200 | 230 | 265 | 300 |
Negative | KV | 155 | 205 | 260 | 340 | 380 | ||
Radio interference voltage | Test voltage to ground | KV | 15 | 22 | 30 | 44 | 44 | 44 |
Max. RIV at 1 MHz | μV | 100 | 100 | 200 | 200 | 200 |
200 |
4. ANSI 57-31, 57-32… series ceramic line post insulators drawings, technical data and images show as follow:
Type | ||||||||
Creepage distance | mm | 356 | 559 | 737 | 1016 | 1143 | 1346 | |
Dry arcing distance | mm | 165 | 241 | 311 | 368 | 438 | 489 | |
Cantilever strength | KN | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 | |
Power frequency flashover voltage | Dry | KV | 70 | 100 | 125 | 140 | 160 | 180 |
Wet | KV | 50 | 70 | 95 | 110 | 130 | 150 | |
Critical impulse flashover voltage | Positive | KV | 120 | 160 | 200 | 230 | 265 | 300 |
Negative | KV | 155 | 205 | 260 | 340 | 380 | ||
Radio interference voltage | Test voltage to ground | KV | 15 | 22 | 30 | 44 | 44 | 44 |
Max. RIV at 1 MHz | μV | 100 | 100 | 200 | 200 | 200 | 200 |
Africa porcelain line post type Insulators
1. Capless line post insulator, the main technical parameters:
Type: | |||||||
Nominal voltage | KV | 22 | 22 | 22 | 33 | 33 | 33 |
Nominal creepage distance | mm | 630 | 750 | 750 | 900 | 1120 | 1120 |
Bottom fixing diameter | mm | M20 OVERSIZE | M20 OVERSIZE | M20 OVERSIZE | M20 OVERSIZE | M20 OVERSIZE | M20 OVERSIZE |
Top fixing diameter | mm | 73 | 73 | 73 | 73 | 73 | 73 |
Top groove radius | mm | 20 | 20 | 20 | 20 | 20 | 20 |
Cantilever strength | KN | 4 | 4 | 10 | 6 | 10 | 4 |
Dry arcing distance | mm | 290 | 325 | 325 | 389 | 390 | 415 |
Power frequency flashover dry | KV | 124 | 109 | 111 | 161 | 105.7 | 137.1 |
Power frequency flashover wet | KV | 84 | 86 | 85 | 123 | 86.4 | 101.1 |
Power frequency withstand dry | KV | 121 | 106 | 106 | 146 | 96 | 131.1 |
Power frequency withstand wet | KV | 76 | 72 | 69 | 85 | 76 | 88.4 |
Impulse withstand voltage (bil) | KV | 183 | 184 | 186 | 230 | 207 | 229.7 |
Impulse flashover positive | KV | 187 | 191 | 193 | 238 | 221.5 | 241.3 |
Impulse flashover negative | KV | 362 | 343 | 344 | 410 | 418.4 | 414.6 |
2. Capped line post insulator, the main technical parameters:
Type | ||||||||||
Nominal voltage | KV | 11 | 11 | 12 | 33 | 33 | 33 | 33 | 33 | 33 |
Nominal creepage distance | mm | 300 | 405 | 400 | 786 | 1050 | 813 | 1100 | 900 | 1116 |
Bottom fixing diameter | mm | M20 | M20 | M20 | M20 | M20 | M20 | M20 | M20 | M20 |
Top fixing diameter | mm | 73 | 73 | 73 | 73 | 73 | 73 | 73 | 73 | 73 |
Top groove radius | mm | 12.5 | 25 | 12.5 | 25 | 25 | 20 | 20 | 25 | 25 |
Cantilever strengh | KN | 7 | 12.5 | 4 | 4 | 12.5 | 10 | 10 | 10 | 12.5 |
Dry arcing distance | mm | 160 | 170 | 218 | 320 | 390 | 335 | 425 | 368 | 432 |
Power frequency flashover dry | KV | 70 | 79.7 | 97 | 131 | 157 | 123 | 140 | 125 | 140 |
Power frequency flashover wet | KV | 40 | 43.7 | 65 | 87 | 106 | 87 | 91 | 95 | 110 |
Power frequency withstand dry | KV | 63 | 75.1 | 91 | 127 | 145.9 | 115 | 124 | 110 | 120 |
Power frequency withstand wet | KV | 35 | 38 | 57 | 75 | 87.6 | 72 | 82 | 78 | 90 |
Impulse withstand voltage (bil) | KV | 100 | 95 | 150 | 205 | 247 | 192 | 245 | 200 | 215 |
Impulse flashover positive | KV | 110 | 142.8 | 164 | 209 | 258.4 | 197 | 255 | 210 | 230 |
Impulse flashover negative | KV | 183 | 218.2 | 263 | 346 | 413.7 | 370 | 414 | 260 | 280 |