Quick Details

Usage:
Power: Electronic
Model Number: AUTO-SPA
Brand Name: AUTOSTRONG
Place of Origin: China (Mainland)
Standard: UL94,IEC60695-11-3,IEC60695-11-20
Power: Electronic
Usage: Flammability testing equipment
Warranty: 1Year
Thermocouple Size: 0.5 mm
Kinds: 500W(5V class ) and 50W(HB/Vclass)
Thermocouple: Type K (Ni/Cr - Ni/Al)

Specifications

Flammability plastic tester  IEC60695 Horizontal and vertical flammability teste


Flammability chamber:
1.for plastics flammability test
2.Shenzhen Manufacturer, OEM offered
3.high quality hot sale


Product Description

1.Application:When there is a fire around the products, should ensure that it will not to cause the spread of the fire, horizontal-vertical burning test simulates electronic products around the environment in the early condition, using the simulation technology to assess the fire risk. The test equipment apply to the electrical and electronic product components of household appliances, spare parts and components, such as: household appliances insulation shell, Panel switches, printed circuit boards and insulation materials and so on.


2.Characteristics:Horizontal and vertical flammability chamber is composed by the test part and control part, using the integrated design, to facilitate the installation at the scene and debug. The shell of the test chamber and the important parts are all manufactured by stainless steel, resistant cigarettes and gas corrosion. The automatic degree of control system is high. Has automatic ignition, the products which were tested in both vertical and horizontal orientation has the function automatically follow flame in the cross of the test. Time and temperature figures show, so that the observation and records is facilitate and the use of it is stable and reliable.

Flammability plastic tester IEC60695 Horizontal and vertical flammability tester

3.Technical Paremeters


Kinds 500W(5V class ) 50W(HB/Vclass)
Horizontal vertical burning tester 500W(burning test for V-0,V-1,V-2 classification) 50W(burning test for V-0,V-1,V-2 classification)
Burner Tube Internal diameter: Φ 9.5mm±0.3mm Internal diameter: Φ 9.5mm±0.3mm,
Burning Angle 0°,20°,45° 0°,20°,45 °
Thermocouple Type K (Ni/Cr - Ni/Al) Type K (Ni/Cr - Ni/Al)
Thermocouple Size 0.5 mm 0.5 mm
Standard Copper Block

Φ9mm±0.01mm,

weight:10g±0.05g before drilling.

Φ5.5mm±0.01mm, weight.76g±0.01g before drilling.
Time for Temperature to Increase

From 100°C±5°C to 700°C±3°C;

54s±2s (preset)

From 100°C±5°C to 700°C±3°C;

44s±2s (preset)

Gas Flow 965±32ml/min 105±10ml/min
Gas Supply methane,min.98% purity methane,min.98% purity
water-column 125m±5mm ?10mm
Test Time 54±2s 44±2s
Flame Height Indicator 40±1mm 20±1mm
Volume Of Chamber >0.5m3, black interior >0.5m3, black interior
Conform to standard UL94,IEC60695-11-3,IEC60695-11-20 UL94,IEC60695-11-4,IEC60695-11-10